WEIDMULLER 8975590000-Dropship Automation

WEIDMULLER 8975590000

SKU: DA-372388
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 8975590000 General Data Accuracy 0.5 % FSR Configuration DIP switch Galvanic isolation 2-way isolator Input/Output 1 /5/ 10 A AC / 4...20 mA (current loop) Rail TS 35 Step response time typ. 700 ms Temperature coefficient ‰¤ 200 ppm/K Voltage supply 13...30 V DC, via output current loop Approvals Approvals CE, CULUSEX, EAC ROHS Conform Dimensions...

Additional Information

Part Number
8975590000

General Data

Accuracy
0.5 % FSR
Configuration
DIP switch
Galvanic isolation
2-way isolator
Input/Output
1 /5/ 10 A AC / 4...20 mA (current loop)
Rail
TS 35
Step response time
typ. 700 ms
Temperature coefficient
‰¤ 200 ppm/K
Voltage supply
13...30 V DC, via output current loop

Approvals

Approvals
CE, CULUSEX, EAC
ROHS
Conform

Dimensions And Weights

Length
72 mm
Length (inches)
2.835 inch
Width
22.5 mm
Width (inches)
0.886 inch
Depth
112.4 mm
Depth (inches)
4.425 inch
Weight
150 g
Net weight
101 g

Connection Data

Type of connection
Screw connection
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²

Tender Specification Sheets

Long specification
Monitoring component for AC currents up to 10A with 4...20 mAloop feed and electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 HzAC currents 0...1 A / 0...5 A / 0...10 A. Input range can be selected using DIP switches.Power is fed to the component via the 4...20 mA current loop on the output side.The input and output circuits have 6 kV of electrical isolation.Approved for ATEX Zone2 and UL C1 D2 applications.Add-on housing for TS35 rail mountingDimensions: L/W/H 72/ 22.5/ 92.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0...1 A / 0...5 A / 0...10 A AC switchable                                      50 / 60 HzVoltage of measuring circuit 250 V ACOutput                                             4...20 mA current loopLoad resistance            < 600 Ohm Strom>1 kOhm / voltageTransmission error               < 0,5% v. E. Temperature coefficient 200 ppm / KStep response time typ. 700 msAuxiliary power                                     via output-side current loopAmbient temperature range 0°C...+50°C Secure isolation                   EN 50178, 2-way isolation up to 6 kVTest voltage                               4 kV input against outputRated voltage                                         300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULus, cULusEX C1D2, ATEX Zone 2Type                                                            WAS1 CMA LP 1/5/10A EX
Short specification
Monitoring component for AC currents up to 10A with 4...20 mAloop feed and electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 HzAC currents 0...1 A / 0...5 A / 0...10 A. Input range can be selected using DIP switches.Power is fed to the component via the 4...20 mA current loop on the output side.The input and output circuits have 6 kV of electrical isolation.Approved for ATEX Zone2 and UL C1 D2 applications.

Input

Number of inputs
1
Input current
0...1 A AC/ 0...5 A AC/ 0...10 A AC
Input frequency
50...60Hz

Classifications

ETIM 6.0
EC002653
ETIM 7.0
EC002653
EClass 9.0
27-21-01-20
EClass 9.1
27-21-01-20
EClass 10.0
27-21-01-20

Output

Number of outputs
1
Output signal limit
Approx. 24 mA
Output current
4...20 mA (current loop)
Load impedance current
‰¤ 600 ©
Offset current
max. 100 µA
Status indicator
LED ON: OK; LED flashing: signal out of range;LED OFF: Error

Product Information

Product information
This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Insulation Coordination

Clearance & creepage distances
‰¥ 5.5 mm
EMC standards
EN 55011, EN 61000-6
Galvanic isolation
2-way isolator
Impulse withstand voltage
6 kV
Insulation voltage
4 kVeff / 5 s
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III

Temperatures

Operating temperature, max.
50 °C
Operating temperature, min.
0 °C
Storage temperature, max.
70 °C
Storage temperature, min.
-20 °C
Operating temperature
0°C...50°C
Storage temperature
-20°C...70°C

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products