WEIDMULLER 8965360000-Dropship Automation

WEIDMULLER 8965360000

SKU: DA-203455
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 8965360000 Probability Of Failure MTBF 215 Years SIL PAPER SIL certificate Digital Output Type NPN-Transitor, Switching frequency 5 kHz Nominal switching voltage 30 V DC Continuous current 80 mA Function Output = input, direct or inverse (configurable) Approvals ROHS Conform UL File Number Search E337701 Dimensions And Weights Width 22.5 mm Width (inches) 0.886 inch Height 119.2 mm Height (inches)...

Additional Information

Part Number
8965360000

Probability Of Failure

MTBF
215 Years
SIL PAPER
SIL certificate

Digital Output

Type
NPN-Transitor, Switching frequency 5 kHz
Nominal switching voltage
30 V DC
Continuous current
80 mA
Function
Output = input, direct or inverse (configurable)

Approvals

ROHS
Conform
UL File Number Search
E337701

Dimensions And Weights

Width
22.5 mm
Width (inches)
0.886 inch
Height
119.2 mm
Height (inches)
4.693 inch
Depth
113.6 mm
Depth (inches)
4.472 inch
Net weight
170 g

Safety-Related Specifications Low Demand Mode

Average Probability of Failure on Demand (PFD
1.58 x 10-4 (Tproof = 1 year), 3.17 x 10-4 (Tproof = 2 years), 7.92 x 10-4 (Tproof = 5 years)

Connection Data

Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.25 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12

Rated Data Ul

UL certificate
E337701.pdf

Safety-Related Basic Specifications

Demand mode
High
Demand rate
1,000 s
Description of the "safe state"
High impedance
Device type
B
Diagnostic test interval
10 s
Hardware fault tolerance (HFT)
0
Mean Time To Repair (MTTR)
8 h
Safe Failure Fraction (SFF)
92 %
T
5 Years
Total failure rate for dangerous detected failures (»
135 FIT
Total failure rate for dangerous undetected failures (»
36 FIT
Total failure rate for safe detected failures (»
0 FIT
Total failure rate for safe undetected failures (»
275 FIT
Safety category
SIL 2
Probability of outage PFH
3.62 x 10-8 h-1

Tender Specification Sheets

Long specification
Ex isolating switch amplifiers for Namur sensors,1-channel isolating switch amplifiers in 22.5 mm width with an external power supply,to transmit and isolate Namur sensor signals from Ex zones 0,1, 2 into the safe zone. On the output side there is an NPN switching transistor and a common alarm contact (relay/"a" contact) for status or error messages.The component can be configured using standard FDT/DTM software.Add-on housing for TS35 DIN rail installationDimensions: L/W/H 119.2/ 22.5/ 113.6screw connection/ nominal cross-section 2.5 mm2Protection degree: IP20   Input                       NAMUR sensor according to EN 60947                                     8 VDC / 8 mA sensor power supply                                     0 to 5 kHz input frequency                                     wire-break detectionOutput                                          NPN transistor                                     30 VDC @ 80 mA                                      5 kHz switching frequency                                     < 2, 5 VDC SpannungsfallAlarm output relay 1 NO contact                                      250 VAC / 30 VDC @ 2A safe zone                                     32 VAC @ 0.5 A/ 32 VDC @ 1 A zone 2Auxiliary power                                    19...31.2 VDCPower loss approx. 1.8 WAmbienttemperature range -20°C to +60°CSecure isolation                  EN 61010, 3-way isolation up to 2.6 kV AC/DC of all circuits against each otherWorking voltage                   300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, ATEX IECEX, FM ATEX marking II 3 G ExnA nC IIC T4 ATEX characteristic data U0 = 10, 6 V DC                                      I0  = 12 mA DC                                      P0 = 32 WType                                                             ACT20X-HDI-2SDO-2SDO-S
Short specification
Ex isolating switch amplifiers for Namur sensors,1-channel isolating switch amplifiers in 22.5 mm width with an external power supply,to transmit and isolate Namur sensor signals from Ex zones 0,1, 2 into the safe zone. On the output side there is an NPN switching transistor and a common alarm contact (relay/"a" contact) for status or error messages.The component can be configured using standard FDT/DTM software.

Alarm Output

Alarm function
Line interruption at the input, Short circuit at input, No supply voltage, Device error
Type
Relay, 1 NC (voltage-free)
Nominal switching voltage
‰¤ 125 V AC / 110 V DC (safe area)‰¤ 32 V AC / 32 V DC (zone 2)
Continuous current
‰¤ 0.5 A AC / 0.3 A DC (safe zone), ‰¤ 0,5 A AC / 1 A DC (zone 2)
Power rating
‰¤ 62.5 VA / 32 W (safe area)‰¤ 16 VA / 32 W (Zone 2)

Classifications

ETIM 6.0
EC002653
ETIM 7.0
EC002653
EClass 9.0
27-21-01-20
EClass 9.1
27-21-01-20
EClass 10.0
27-21-01-20
UNSPSC
30-21-18-01

Output

Influence of load resistance
‰¤ 0.01% of span / 100 ©

Product Information

Product information
Weidmüller provides an extended guarantee period of 36 months for this device.

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Data For Ex Applications (Atex)

Voltage U
10.6 V DC
Current I
12 mA DC
Power P
32 mW
Marking
II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Installation location
Device installed in safe area, zone 2

Insulation Coordination

EMC standards
DIN EN 61326, NE 21
Insulation voltage
2.6 kV (input / output)
Rated voltage
300 V

Input Ex

Input frequency
0...5 kHz
Input resistance
1 k©
Output signal in case of wire break
< 0.1 mA, > 6.5 mA (in case of wire break)
Pulse duration
> 0.1 ms
Resistance
Series resistor 750©, Parallel resistor 15k©
Sensor
NAMUR sensor, according to EN60947, switch with or without RS, RP
Sensor supply
8 V DC / 8 mA
Trigger level high
> 2.1 mA
Trigger level low
< 1.2 mA
Type
intrinsically safe circuit

Temperatures

Humidity
0...95 % (no condensation)
Operating temperature, max.
60 °C
Operating temperature, min.
-20 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-20 °C
Operating temperature
-20°C...60°C
Storage temperature
-20°C...85°C

Ratings Iecex/Atex/Cul

ATEX certificate
09ATEX0168X.pdf
IEC Ex certificate
IECEx certification
Certificate No. (ATEX)
KEMA09ATEX0168X
Certificate No. (IECEX)
IECEXKEM09.0072X
Certificate no. (cULus)
E337701

General Specifications

Configuration
With FDT/DTM software
Voltage supply
19.2€¦31.2 V DC
Type of connection
Screw connection
NAMUR supply
8 V DC / 8 mA
Power consumption
‰¤ 1.1 W
Protection degree
IP20
Humidity
0...95 % (no condensation)

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products