Additional Information
- Part Number
- 8953610000
Further Details Of Approvals
- GOST certificate
- GOST-Zertifikat
Protection Ex - Data
- ATEX - dust labelling
- II 1 D Ex ia IIIC T135°C ¦T85°C Da
- ATEX - gas labelling
- II 1 G Ex ia IIC T4¦ T6 Ga
- Certificate No. (ATEX)
- KEMA10ATEX0148X
- IECEx - dust labelling
- II 1 D Ex ia IIIC T135°C ¦T85°C Da
- IECEx - gas labelling
- II 1 G Ex ia IIC T4¦ T6 Ga
- Input power, max. P
- 3 W
- Input voltage, max. U
- 20 V
- Internal capacity, max. C
- < 4 nF
- Internal inductance, max. L
- 0 µH
- Temperature class T4/135°C (-40°C ... +85°C) li
- 350 mA
- Temperature class T5/100°C (-40° C ... +75°C) li
- 250 mA
- Temperature class T6/85°C (-40°C ... +60°C) li
- 250 mA
General Data
- Colour
- Light Blue
- Design
- Terminal, miscellaneous
- Optical function display
- For Class III protection, green = OK; red = arrester is defective - replace
- Protection degree
- IP20
- Segment
- Measurement - Monitoring - Setting
- UL 94 flammability rating
- V-0
- Version
- without warning function / function indicator
Probability Of Failure
- ›ges
- 45
- MTTF
- 2,537 Years
- PFH in 1*10
- 1.95
- SFF
- 95.67 %
- SIL PAPER
- SIL Paper
- SIL in compliance with IEC 61508
- 3
Approvals
- Approvals
- CE, CSAEX, EAC, FUSAFETY, IECEXDEK, KEMAATEX
- ROHS
- Conform
Insulation Coordination Acc. To En 50178
- Pollution severity
- 2
- Surge voltage category
- III
Rated Data Iec / En
- Combined pulse U
- 6 kV
- Dielectric strength at FG against PE
- ‰¥ 500 V
- Discharge current I
- 2.5 kA
- Input voltage, max. U
- 20 V
- Lightning test current, I
- 2.5 kA
- Max. continuous voltage, Uc (AC)
- 27 V
- Max. continuous voltage, Uc (DC)
- 38 V
- Number of poles
- 1
- Overload - failure mode
- Modus 2
- Protection level U
- ‰¤ 0.9 kV
- Protection level on output side Wire-PE 1kV/µs, typically
- 450 V
- Protection level on output side Wire-wire 1 kV/µs, typically
- 60 V
- Protection level on output side Wire-wire 8/20 µs, typically
- 60 V
- Protection level, U
- 40 V
- Pulse-reset capacity
- ‰¤ 10 ms
- Rated current I
- 350 mA
- Rated voltage (AC)
- 24 V
- Rated voltage (DC)
- 24 V
- Requirements category acc. to IEC 61643-21
- C1, C2, C3, D1
- Signal transmission properties (-3 dB)
- 3 MHz
- Signalling contact
- No
- Standards
- IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006, HART-compatible
- Surge current-carrying capacity C1
- < 1 kA 8/20 ¼s
- Surge current-carrying capacity C2
- 5 kA 8/20 ¼s
- Surge current-carrying capacity C3
- 100 A 10/1000 ¼s
- Surge current-carrying capacity D1
- 2.5 kA 10/350 ¼s
- Voltage type
- AC/DC
- Volume resistance
- 2.20 ©
Dimensions And Weights
- Width
- 17.8 mm
- Width (inches)
- 0.701 inch
- Height
- 90 mm
- Height (inches)
- 3.543 inch
- Depth
- 69 mm
- Depth (inches)
- 2.717 inch
- Net weight
- 56 g
Csa Protection Data
- Gas group C
- IIB
- Gas group D
- IIA
- Gas groups A, B
- IIC
- Input voltage, max. U
- 27 V
- Internal capacity, max. C
- 25 nF
- Internal inductance, max. L
- 0 µH
Connection Data
- Type of connection
- Pluggable in VSPC BASE
Tender Specification Sheets
- Long specification
- Surge protection plug for base element VSPC BASE 1CL PW FG EX with dual protective circuits, for intrinsically sage power supply and a paired cable for floating-ground powered intrinsically sage signal circuit (forexample, EX ia supply isolation amplifiers) protective switched power supply: temperature controlled varistors as a cross-protection between the active lines. Coarse protection of the common mode voltage to earth. Optical defect signal coupled with the temperature monitoring. Protective circuits, floating-ground driven signal circuits: two-stage protection switches consisting of coarse and fine protection between the signal wires as well as decoupling resistors. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug.
- Short specification
- Surge protection plug for base element VSPC BASE 1CL PW FG EX with dual protective circuits, for 24 V power supply and a paired cable for floating-ground powered signal circuit. Suitable for protecting intrinsically safe Ex ia circuits.
Classifications
- ETIM 6.0
- EC000943
- ETIM 7.0
- EC000943
- EClass 9.0
- 27-13-08-07
- EClass 9.1
- 27-13-08-07
- EClass 10.0
- 27-13-08-07
- UNSPSC
- 30-21-19-21
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Temperatures
- Humidity
- 5...96 %
- Operating temperature, max.
- 70 °C
- Operating temperature, min.
- -40 °C
- Storage temperature, max.
- 80 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -40°C...70°C
- Storage temperature
- -40°C...80°C
Ratings Iecex/Atex/Cul
- ATEX certificate
- ATEX Certificate
- IEC Ex certificate
- IECEX Zertifikat
- Certificate No. (ATEX)
- KEMA10ATEX0148X
- CUL certificate
- cUL Certificate