Additional Information
- Part Number
- 8939670000
General Data
- Accuracy
- < 0.1 % span (DC, RTD); 0.2 % span (or 1°C) + CJ failure
- Configuration
- Using free Windows software, TTA Set Software
- Power consumption
- < 3.5 W
- Step response time
- 50 ms...1 sec (RTD, mV inputs), 110 ms...1 sec (V, mA inputs)
- Temperature coefficient
- < 0.1 % / K (DC, RTD); < 0.1 % FSR / K + CJ error 0.07°C/K (thermocouples)
- Voltage supply
- 18...264 V AC/DC
Probability Of Failure
- MTTF
- 138 Years
Approvals
- Approvals
- CE, CULUS, DNV GL, EAC
- ROHS
- Conform
- UL File Number Search
- E141197
Dimensions And Weights
- Length
- 100 mm
- Length (inches)
- 3.937 inch
- Width
- 45 mm
- Width (inches)
- 1.772 inch
- Depth
- 112.4 mm
- Depth (inches)
- 4.425 inch
- Weight
- 215 g
- Net weight
- 256.1 g
Output (Digital)
- Alarm function
- Top and bottom limit values, window range, Over-temperature, Alarm mode: delay, switch on or switch on/off, Holding function can be activated, Delayed 0...4200 s
- Number of digital outputs
- 2
- Type
- 2 x 1 CO contact (hard gold-plated), Process alarms (4x) with hysteresis, with alarm delay (configurable) 0¦180 s
- Max. switching voltage, AC
- 250 V
Connection Data
- Type of connection
- Screw connection
- Stripping length, rated connection
- 7 mm
- Tightening torque, min.
- 0.4 Nm
- Tightening torque, max.
- 0.5 Nm
- Clamping range, rated connection
- 2.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, max.
- 2.5 mm²
Tender Specification Sheets
- Long specification
- Universal measurement isolating converters and trip amplifiers; can be configured with PCUniversal measurement isolating converters and trip amplifiers in 45 mm width with external supply for voltage and sensors, for transmitting and isolating analogue DC current -20 to 50 mA, voltages -200 to 500 mV/ -20 to 50 V, 2-/3-/-4-wire RTD, resistors, thermocouples according to IEC 584 and frequencies up to 100 kHz( 2- / 3-wire sensors). Two switching outputs (CO contact) for alarms, analogue DC voltages (-10 to +10 V) and current outputs (0 to 20 mA) are available on the output side. The component can be configured with a PC using the proprietary TTA-Set software. Add-on housing for TS35 DIN rail installation Dimensions: L/W/H 100/ 45/ 112.4 mm screw connection / nominal cross-section 2.5 mm2Protection degree: IP20 input -20 to 50 mA -200 to 500 mV / -10 to +10 V PT100, PT1000, Ni100, Ni1000, Cu10/25/50/100 2-/3-/4-wire resistance 10 Ohm to 5 kOhm/ Potentiometer 100 Ohm to 100 kOhm thermocouple types B, E, J, K, N, R, S, T frequencies 2 Hz to 100 kHz (2-/3-wire sensors) sensor supply 24 VDC / 22 mAoutput analogue 0 to 20 mA / adjustable -10 to +10 V/ adjustable relay output / alarm 2 CO contacts, hard gold-plated 250 VAC @ 3 A / 30 VDC @ 2A load resistance < 700 Ohm/ current / >10 kOhm/ voltageTransmission error Step response time10...90 % < 0,1 % v. E. (DC, RTD) Auxiliary power 18...264 V AC/DC< 50 ms...1 s einstellbar Power loss approx. 3.5 WAmbient temperature range -25°C...+70°C Isolation EN 50178 secure 3-way isolation up to 6 kV of all circuits against each otherTest voltage 2.5 kV input against output against auxiliary powerRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus, GL Type WAS6 TTA
- Short specification
- Universal measurement isolating converters and trip amplifiers; can be configured with PCUniversal measurement isolating converters and trip amplifiers in 45 mm width with external supply for voltage and sensors, for transmitting and isolating analogue DC current -20 to 50 mA, voltages -200 to 500 mV/ -20 to 50 V, 2-/3-/-4-wire RTD, resistors, thermocouples according to IEC 584 and frequencies up to 100 kHz( 2- / 3-wire sensors).Two switching outputs (CO contact) for alarms, analogue DC voltages (-10 to +10 V) and current outputs (0 to 20 mA) are available on the output side.The component can be configured with a PC using the proprietary TTA-Set software.
Input
- Number of inputs
- 1
- Sensor
- Thermocouples: B, E, J, K, L, N, R, S, T (IEC 60584), PT100, PT1000, (EN 60571) Ni100, Ni1000, (JIS1604), Cu10, Cu25, Cu50, Cu100 (DIN 43760) 2-/3-/4-wire
- Sensor supply
- 24 V DC / 22 mA
- Input voltage
- -200...500 mV (min. 4 mV span), -20...50 V DC (min. 0.5 V span)
- Input current
- -20...+50 mA (min. interval 0.4 mA)
- Input frequency
- 2 Hz¦100 kHz
- Resistance
- 10 ©¦5 k©
- Potentiometer
- 100 ©...100 k©
Output (Analogue)
- Load resistance current
- < 700 ©
- Load resistance voltage
- > 10 k© @ 0...10 V / > 20 k© @ -10...+10 V
- Output current
- adjustable between 0 and 20 mA (min. span of 5 mA)
- Output voltage
- adjustable between -10...+10 V (min. span 2.5 V)
- Signal output
- direct or inverted
- Transmit function
- Linear, x1/2, x3/2, x5/2 or user-defined curve (101 points)
Classifications
- ETIM 6.0
- EC002653
- ETIM 7.0
- EC002653
- EClass 9.0
- 27-21-01-20
- EClass 9.1
- 27-21-01-90
- EClass 10.0
- 27-21-01-20
- UNSPSC
- 30-21-18-01
Product Information
- Product information
- WAS/WAZ6 TTA is a universal signal converter and trip amplifier that can be configured on the PC. Combines the functions of isolation, transmission, linearisation and trip amplification in a single module.These exceptional characteristics and outstanding configurability combine to make the TTA truly unique. The TTA functions with stability and precision under a wide range of voltages and ambient temperatures. It is compatible with all standard sensor types. Universal input signals: temperature signals such as resistance thermometer, thermocouple, potentiometer, frequency transmitter, DC voltage signals and current signalsLoop-powered or passive inputWide-range power supply: 18 “ 264 V AC/DCUser-defined linearizationInputs and outputs can be configured on PCCombined analogue and relay outputAmbient temperature range: -40°C ¦70°CThe CBX200 USB interface is used to connect to the PC. The WAS/WAZ6 TTA is also offered as an option with ATEX Zone 2 and UL C1D2 approvals.
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Insulation Coordination
- Clearance & creepage distances
- ‰¥ 5.5 mm (1 mm input/output)
- EMC standards
- EN 55011, EN 61000-6
- Impulse withstand voltage
- 6 kV
- Insulation voltage
- 2.5 kV
- Pollution severity
- 2
- Rated voltage
- 300 V
- Surge voltage category
- III
Temperatures
- Humidity
- 5...95 %, no condensation
- Operating temperature, max.
- 70 °C
- Operating temperature, min.
- -40 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -40°C...70°C
- Storage temperature
- -40°C...85°C
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E141197