Additional Information Part Number 8742620000 General Data Configuration none Galvanic isolation Without isolation Rail TS 35 Approvals Approvals CE, CULUS ROHS Conform UL File Number Search E141197 Dimensions And Weights Length 92 mm Length (inches) 3.622 inch Width 15.3 mm Width (inches) 0.602 inch Depth 95 mm Depth (inches) 3.74 inch Weight 76 g Net weight 70.8 g Output (Digital) Max. switching voltage, DC 100 V Max. switching voltage,...

Additional Information

Part Number
8742620000

General Data

Configuration
none
Galvanic isolation
Without isolation
Rail
TS 35

Approvals

Approvals
CE, CULUS
ROHS
Conform
UL File Number Search
E141197

Dimensions And Weights

Length
92 mm
Length (inches)
3.622 inch
Width
15.3 mm
Width (inches)
0.602 inch
Depth
95 mm
Depth (inches)
3.74 inch
Weight
76 g
Net weight
70.8 g

Output (Digital)

Max. switching voltage, DC
100 V
Max. switching voltage, AC
100 V
Continuous current
100 mA
Contact material
RH/Rd (Reed contact)*

Connection Data

Type of connection
Screw connection
Clamping range, rated connection
1.5 mm²
Clamping range, min.
2.5 mm²
Clamping range, max.
2.5 mm²

Tender Specification Sheets

Long specification
Limit-value monitoring of DC currents up to 5 A with switching outputlimit-value monitoring component for measuring DC currents 2...5 A withswitching output. The monitoring unit is designed so that it can be plugged onto the mounting base.Pluggable unit on base, for mounting on TS35 DIN rail Dimensions: L/W/H 92/ 15.3/ 95 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20Input                         2 ...5 A DC / Reed relay coilSwitch-on threshold         < 2 ASwitch-off threshold       < 300 mAOutput                                             1 NO / Reed contactSwitching current max 100 mA AC/DCSwitching voltage 100 V AC / 50 V DCAmbient temperature range 0°C...+55°C Secure isolation                   EN 50178, 2-way isolation up to 6 kVTest voltage                               4 kVeff / 1 min. input against outputRated voltage                                          300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType                                                            PAS CMR 2.0...5.0 A DC
Short specification
Limit-value monitoring of DC currents up to 5 A with switching outputlimit-value monitoring component for measuring DC currents 2...5 A withswitching output. The monitoring unit is designed so that it can be plugged onto the mounting base.

Input

Input current
2...5.0 A DC
Input resistance, current
< 50 m©
Pulse duration
min. 1 ms

Classifications

ETIM 6.0
EC002654
ETIM 7.0
EC002654
EClass 9.0
27-21-01-22
EClass 9.1
27-21-01-22
EClass 10.0
27-21-01-22
UNSPSC
30-21-19-17

Insulation Coordination

Clearance & creepage distances
‰¥ 5 mm (grout encapsulated)
EMC standards
EN 55011, EN 61000-6-1, 2, 3, 4
Galvanic isolation
Without isolation
Impulse withstand voltage
6 kV
Insulation voltage
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III

Temperatures

Humidity
5-95% relative humidity, Tu = 40°C, without condensation
Operating temperature, max.
55 °C
Operating temperature, min.
0 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-40 °C
Operating temperature
0°C...55°C
Storage temperature
-40°C...85°C

Ratings Iecex/Atex/Cul

Certificate no. (cULus)
E141197

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products