Additional Information
- Part Number
- 8705640000
General Data
- Configuration
- DIP switch and potentiometer, Alarm status reset via reset input or button
- Galvanic isolation
- 3-way isolator
- Rail
- TS 35
- Repeat accuracy
- < 0.3 % of set range
- Step response time
- < 300 ms
- Temperature coefficient
- ? 250 ppm/K of measuring range
- Voltage supply
- from the measuring circuit
Probability Of Failure
- MTTF
- 587 Years
Approvals
- Approvals
- CE, CULUS, EAC
- ROHS
- Conform
- UL File Number Search
- E141197
Dimensions And Weights
- Length
- 96.5 mm
- Length (inches)
- 3.799 inch
- Width
- 17.5 mm
- Width (inches)
- 0.689 inch
- Depth
- 112.4 mm
- Depth (inches)
- 4.425 inch
- Net weight
- 132 g
Output (Digital)
- Alarm function
- configurable, Surge voltage, Undervoltage, Hysteresis: 10 V
- Type
- Relay, 1 CO contact
- Max. switching voltage, AC
- 250 V
- Continuous current
- 3 A
Connection Data
- Type of connection
- Screw connection
- Clamping range, rated connection
- 2.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, max.
- 2.5 mm²
Tender Specification Sheets
- Long specification
- Limit-value monitoring component for 1-phase AC / DC voltages with relay outputand electrical isolationlimit-value monitoring component in 17.5 mm width for recording AC / DCvoltages 24...70 V / 70...140 V / 140...210 V / 210...260 V.A relay contact (CO) with a switching capacity of 750 VAis available on the output side.Input ranges, high/low tripswitching behaviour, hysteresis and memory behaviour can be configured using DIP switches. Switching threshold can be adjusted with front-side potentiometerPower is supplied using the measured circuit.The memory function can be activated using an external reset input 18...30 VDC.Input/output/reset have 4 kV of electrical isolation.Add-on housing for TS35 rail mountingDimensions: L/W/H 96.5/ 17.5/ 112.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 24...70 V / 70...140 V / 140...210 V / 210...260 V AC/DC. SwitchableVoltage of measuring circuit max 260 VOutput Relay / COSwitching current 3 ASwitching voltage 6... 250 V AC / 6...60 V DCSwitching threshold 10...90 % via potentiometerHysteresis 24...70 V switchable 5 V / 10V 70...260 V switchable 8 V / 16 V Temperature coefficient < 250 ppm KStep response time < 300 msReset input 18...30 VDC / max 700 msAmbient temperature range 0°C...+50°C Secure isolation EN 50178, 2-way isolation up to 4 kVTest voltage 2 kVeff Input / Output / Reset inputRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType WA5 VMR 1ph
- Short specification
- Limit-value monitoring component for 1-phase AC / DC voltages with relay output and electrical isolationlimit-value monitoring component in 17.5 mm width for recording AC / DC voltages 24...70 V / 70...140 V / 140...210 V / 210...260 V. A relay contact (CO) with a switching capacity of 750 VA is available on the output side. Input ranges, high/low trip switching behaviour, hysteresis and memory behaviour can be configured using DIP switches. Switching threshold can be adjusted using the front-side potentiometer. The input circuit is used for the power supply. The memory function can be activated using an external reset input 18...30 VDC. The input/output/reset have 4 kV of electrical isolation.
Input
- Number of inputs
- 1 x single-phase (L, N)
- Input voltage
- 24...70 / 70...140 / 140...210 / 210...260 V AC / DC, max. 260 V AC ? DC
- Input frequency
- 50...60Hz
Classifications
- ETIM 6.0
- EC002653
- ETIM 7.0
- EC002653
- EClass 9.0
- 27-21-01-20
- EClass 9.1
- 27-21-01-20
- EClass 10.0
- 27-21-01-20
- UNSPSC
- 30-21-18-01
Product Information
- Product information
- This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Insulation Coordination
- Clearance & creepage distances
- ? 3 mm
- EMC standards
- EN 61000-6-2, EN 61000-6-4
- Galvanic isolation
- 3-way isolator
- Impulse withstand voltage
- Input/output, input/reset input, reset input/output: 4 kV
- Insulation voltage
- 2 kVeff
- Pollution severity
- 2
- Rated voltage
- input/output, input/reset input, reset input/output: 300 V
- Surge voltage category
- III
Temperatures
- Operating temperature, max.
- 55 °C
- Operating temperature, min.
- -10 °C
- Storage temperature, max.
- 70 °C
- Storage temperature, min.
- -20 °C
- Operating temperature
- -10°C...55°C
- Storage temperature
- -20°C...70°C
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E141197