Additional Information
- Part Number
- 8638950000
General Data
- Accuracy
- Slow/fast step response time: 0.5% of measuring range or 0.5 K/ 1% of measuring range or 1 K
- Configuration
- DIP switch
- Current-carrying capacity of cross-connect.
- ¤ 2 A
- Galvanic isolation
- 3-way isolator
- Input/Output
- configurable
- Linearity
- Yes
- Power consumption
- 880...980...1030 mW at IOUT = 20 mA
- Rail
- TS 35
- Step response time
- Fast: 1.2 s/ slow: 2.2 s
- Temperature coefficient
- span 100 K: ¤ 250 ppm/K of measuring range40 K <= span <= 100 K: <= 400 ppm/K of measuring range
- Voltage supply
- 24 V DC ± 20 %
Probability Of Failure
- MTTF
- 267 Years
Approvals
- Approvals
- CE, CULUS, CULUSEX, EAC
- ROHS
- Conform
- UL File Number Search
- E141197
Dimensions And Weights
- Length
- 92.4 mm
- Length (inches)
- 3.638 inch
- Width
- 17.5 mm
- Width (inches)
- 0.689 inch
- Depth
- 112.4 mm
- Depth (inches)
- 4.425 inch
- Weight
- 100 g
- Net weight
- 103.5 g
Connection Data
- Type of connection
- Screw connection
- Stripping length, rated connection
- 7 mm
- Tightening torque, min.
- 0.4 Nm
- Tightening torque, max.
- 0.5 Nm
- Clamping range, rated connection
- 2.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, max.
- 2.5 mm²
Tender Specification Sheets
- Long specification
- RTD measurement isolating transformer; configured with DIP switchesRTD measurement isolating transformer in 17.5 mm width with external power supply,for transmitting and isolating 2-/3-/-4-wire Cu10/ 25/ 50/ 100 signals. Analogue DC signals 0(4) to 20 mA / 0 to 10 V are available on the output side.Internal potentiometer is used for zero and span calibrations.Add-on housing for TS35 rail mountingDimensions: L/W/H 92.4/ 17.5/ 112.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input3-/4-wire Cu 10, Cu 25, Cu 50, Cu 100Output 0/4...20 mA 0...10 VLoad resistance < 600 Ohm/ Strom/> 1 kOhm/ voltageTransmission error < 0,8% v. E. (RTD) typ. 200 ppm /°CAuxiliary power 24 VDC +/- 25 %Power loss approx. 0.9 WAmbient temperature range 0°C...+55°CIsolation EN 50178, 3-way isolation up to 4 kV AC/DC of all circuits against each otherTest voltage2 kV input against output against auxiliary powerRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULus, cULusEXType WAS5 PRO RTD Cu
- Short specification
- RTD measurement isolating transformer; configured with DIP switchesRTD measurement isolating transformer in 17.5 mm width with external power supply,for transmitting and isolating 2-/3-/-4-wire Cu10/ 25/ 50/ 100 signals. Analogue DC signals 0(4) to 20 mA / 0 to 10 V are available on the output side.Internal potentiometer is used for zero and span calibrations.
Input
- Number of inputs
- 1
- Sensor
- 3-/4-wired, Cu 10. Cu 25, Cu 50. Cu 100
- Line resistance in measuring circuit
- 5 © Cu 10; 15 © Cu 25; 25 © Cu 50; 50 © Cu 100
- Temperature input range
- Adjustable from -200...+260°C
Classifications
- ETIM 6.0
- EC002919
- ETIM 7.0
- EC002919
- EClass 9.0
- 27-21-01-29
- EClass 9.1
- 27-21-01-29
- EClass 10.0
- 27-21-01-29
- UNSPSC
- 30-21-18-01
Output
- Number of outputs
- 1
- Output voltage, note
- 0...10 V
- Output current
- 0...20 mA, 4...20 mA
- Wire break detection
- LED flashing (output value: > 20 mA, >10 V)
- Fine adjustment
- ± 12.5% of FSR
- Load impedance voltage
- 1 k©
- Load impedance current
- ¤ 600 ©
- Offset voltage
- max. 0.05 V
- Offset current
- max. 100 µA
- Status indicator
- Module active: LED on/ wire breakage: LED flashing/Error: LED off
Product Information
- Product information
- This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Insulation Coordination
- Clearance & creepage distances
- 3 mm
- EMC standards
- EN 55011, EN 61000-6
- Galvanic isolation
- 3-way isolator
- Impulse withstand voltage
- 4 kV
- Insulation voltage
- 2 kVeff / 5 s
- Insulation voltage input or output/rail
- 4 kVeff / 1 min.
- Insulation voltage input or output/supply
- 2 kVeff / 5 s
- Pollution severity
- 2
- Rated voltage
- 300 V
- Surge voltage category
- III
Temperatures
- Operating temperature, max.
- 55 °C
- Operating temperature, min.
- 0 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -20 °C
- Operating temperature
- 0°C...55°C
- Storage temperature
- -20°C...85°C
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E141197