WEIDMULLER 8543820000-Dropship Automation

WEIDMULLER 8543820000

SKU: DA-547960
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 8543820000 General Data Accuracy Repeat accuracy: max. ± 0.3% of measuring range end value (10 V/ 20 mA) Configuration DIP switch, Potentiometer Current-carrying capacity of cross-connect. ¤ 2 A Galvanic isolation 3-way isolator Input/Output 0...10 V, 0(4)...20 mA / 2 CO contact Power consumption Typ.: 1 W both relays picked up Rail TS 35 Temperature coefficient...

Additional Information

Part Number
8543820000

General Data

Accuracy
Repeat accuracy: max. ± 0.3% of measuring range end value (10 V/ 20 mA)
Configuration
DIP switch, Potentiometer
Current-carrying capacity of cross-connect.
¤ 2 A
Galvanic isolation
3-way isolator
Input/Output
0...10 V, 0(4)...20 mA / 2 CO contact
Power consumption
Typ.: 1 W both relays picked up
Rail
TS 35
Temperature coefficient
¤ 500 ppm/K
Voltage supply
24 V DC ± 25 %

Probability Of Failure

MTTF
369 Years

Approvals

Approvals
CE, CULUS
ROHS
Conform
UL File Number Search
E141197

Dimensions And Weights

Length
92.4 mm
Length (inches)
3.638 inch
Width
17.5 mm
Width (inches)
0.689 inch
Depth
112.4 mm
Depth (inches)
4.425 inch
Weight
137 g
Net weight
110.1 g

Output (Digital)

Alarm function
configurable, High or low alarm, Hysteresis 5% / 10%
Hysteresis
1...10 % (independent for channel 1 and channel 2)
Type
2 CO contacts, Open or closed-circuit principle
Max. switching voltage, AC
250 V
Continuous current
3 A
Contact material
AgNi 90/10

Connection Data

Type of connection
Screw connection
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²

Tender Specification Sheets

Long specification
Limit-value monitoring component for DC- current-/ voltage standard signals with relay output and 3-way electrical isolation.Limit-value monitoring component in 22.5 mm width for recording 0(4)...20 mA / 0...10 V standard signals. Two relay contacts (COs), each with a switching capacity of 750 VA, are available on the output side for monitoring an upper and lower limit. The switching behaviour (high/low trip,  fail-safe) can be selected using DIP switches. Switching thresholds and hystereses can be adjusted with the front-side potentiometer. The component has 4 kV of 3-way isolation and is supplied externally with 24 VDC. Add-on housing for TS35 rail mounting Dimensions: L/W/H 92.4/ 22.5/ 112.4 mm Screw connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0(4)...20 mA / 0...10 VOutput                                             2 x relay / CO                                       Open-circuit/closed-circuit principle Switching current 3 A Switching voltage 6... 250 V AC / 6...60 V DC Switching thresholds 1...90 % via potentiometer (independently for channels 1 and 2)Hysteresis                     1% ... 10 % via potentiometer (independently for channels 1 and 2) Temperature coefficient   < 500 ppm K Step response time        < 60 ms (10...90 %)Auxiliary power                                     24 VDC +/- 25 % Ambient temperature range 0°C...+55°C Secure isolation                   EN 50178, 3-way Isolation up to 4 kVTest voltage                               2 kVeff / 5s Input / Output/ SupplyRated voltage                                          300 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus Type                                                             WAS5 DC/Alarm
Short specification
Limit-value monitoring component for DC- current/voltage standard signals with relay output and 3-way electrical isolation.Limit-value monitoring component in 22.5 mm width for recording 0(4)...20 mA / 0...10 V standard signals.  Two relay contacts (COs), each with a switching capacity of 750 VA, are available on the output side for monitoring an upper and lower limit. The switching behaviour (high/low trip,  fail-safe) can be selected using DIP switches. Switching thresholds and hystereses can be adjusted with the front-side potentiometer. The component has 4 kV of 3-way isolation and is supplied externally with 24 VDC.

Input

Number of inputs
1
Input voltage
0...10 V
Input resistance, voltage
100 k©
Input current
0(4)...20 mA
Input resistance, current
¤ 110 ©

Classifications

ETIM 6.0
EC002653
ETIM 7.0
EC002653
EClass 9.0
27-21-01-20
EClass 9.1
27-21-01-20
EClass 10.0
27-21-01-20

Output

Contact material
AgNi 90/10
Switching thresholds
1...90 % (independently for channel 1 and channel 2)
Status indicator
LED green ON: OK, LED red ON: alarm (per channel)

Product Information

Product information
This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Insulation Coordination

Clearance & creepage distances
3 mm
EMC standards
EN 61000-4-2, -3, -4, -5, -6
Galvanic isolation
3-way isolator
Impulse withstand voltage
4 kV
Insulation voltage
2 kVeff / 5 s
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III

Temperatures

Humidity
40°C / 93 % rel. humidity, no condensation
Operating temperature, max.
55 °C
Operating temperature, min.
0 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-20 °C
Operating temperature
0°C...55°C
Storage temperature
-20°C...85°C

Ratings Iecex/Atex/Cul

Certificate no. (cULus)
E141197

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products