Additional Information Part Number 8543730000 General Data Accuracy 0.2% of measuring range final value Configuration DIP switch Galvanic isolation Passive isolator Input/Output 0(4)...20 mA, 0...(5)10 V / 4...20 mA (current loop) Rail TS 35 Step response time < 10 Hz: 80 ms; 100 Hz: 50 ms Temperature coefficient ¤ 150 ppm/K Voltage supply min. 12 V DC/ max. 30 V...

Additional Information

Part Number
8543730000

General Data

Accuracy
0.2% of measuring range final value
Configuration
DIP switch
Galvanic isolation
Passive isolator
Input/Output
0(4)...20 mA, 0...(5)10 V / 4...20 mA (current loop)
Rail
TS 35
Step response time
< 10 Hz: 80 ms; 100 Hz: 50 ms
Temperature coefficient
¤ 150 ppm/K
Voltage supply
min. 12 V DC/ max. 30 V DC, Loop powered, via 4¦20 mA input

Probability Of Failure

MTTF
366 Years

Approvals

Approvals
CE, CULUS, EAC
ROHS
Conform
UL File Number Search
E141197

Dimensions And Weights

Length
92.4 mm
Length (inches)
3.638 inch
Width
17.5 mm
Width (inches)
0.689 inch
Depth
112.4 mm
Depth (inches)
4.425 inch
Net weight
111 g

Connection Data

Type of connection
Tension-clamp connection
Stripping length, rated connection
7 mm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²

Tender Specification Sheets

Long specification
Standard signal isolating amplifier, output-current loop fed1-channel isolating amplifier in 17.5 mm width, output-current loop fed, for transmitting and isolating analogue DC- current signals from 4...20 mA and voltage signals from 0...(5)10 V. Add-on housing for TS35 DIN rail installation Dimensions: L/W/H 92.4/ 17.5/ 112.4 mm Tension-clamp connection / nominal cross-section 1.5 mm²Protection degree: IP 20 Input0(4)...20 mA 0...5 V / 0...10 V Output 4...20 mA Load resistance / R = (UB-12 V) / 20 mA z.b 600 Ohm at 20 mA Transmission error Auxiliary power 4...20 mA output current loopAmbienttemperature range 0°C...+55°C Isolation EN 50178 , 2-way isolation up to 4 kV AC/DC Test voltage 4 kV Rated voltage 300 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus Type WAZ5 CCC OLP
Short specification
Standard signal isolating amplifier, output-current loop fed1-channel isolating amplifier in 17.5 mm width, output-current loop fed,for transmitting and isolating analogue DC- current signals from 4 to 20 mA and voltage signals from 0 to (5)10 V.

Input

Number of inputs
1
Input voltage
0...(5)10 V
Input resistance, voltage
0...5 V: 210 k©; 0...10 V: 430 k©
Input current
0...20 mA, 4¦20mA
Input resistance, current
51 ©

Classifications

ETIM 6.0
EC002653
ETIM 7.0
EC002653
EClass 9.0
27-21-01-20
EClass 9.1
27-21-01-20
EClass 10.0
27-21-01-20
UNSPSC
31-12-10-07

Output

Number of outputs
1
Output signal limit
Approx. 31 mA
Output current
4...20 mA (current loop)
Cut-off frequency (-3 dB)
10 Hz/ 100 Hz switchable
Load impedance current
RL = (UB-12 V) / 20 ± 20mA, e.g. 600 © at 24 V
Status indicator
Green LED

Product Information

Product information
This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Insulation Coordination

Clearance & creepage distances
5.5 mm
EMC standards
EN 55011, EN 61000-6
Galvanic isolation
Passive isolator
Impulse withstand voltage
4 kV
Insulation voltage
4 kVeff / 5 s
Insulation voltage input or output/rail
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III

Temperatures

Operating temperature, max.
55 °C
Operating temperature, min.
0 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-20 °C
Operating temperature
0°C...55°C
Storage temperature
-20°C...85°C

Ratings Iecex/Atex/Cul

Certificate no. (cULus)
E141197

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products