Additional Information
- Part Number
- 2580270000
General Data
- Degree of efficiency
- 89%
- Housing version
- Plastic, protective insulation
- MTBF
- >; 750.000 h nach IEC 61709 (SN29500)
- Mounting position, installation notice
- Horizontal on DIN rail TS 35, top and bottom 50 mm clearance for free air flow, 10 mm clearance to neighbouring active subassemblies with full load, 5 mm with passive neighbouring subassemblies, direct row mounting with 90% rated load
- Operating temperature
- -25°C...70°C
- Power loss, idling
- 0.45 W
- Power loss, nominal load
- 10.56 W
- Protection against reverse voltages from the load
- 58¦62 V DC
- Protection degree
- IP20
Signalling
- LED green
- Operating voltage OK
Connection Data (Input)
- Conductor cross-section, AWG/kcmil , max.
- 12
- Conductor cross-section, AWG/kcmil , min.
- 24
- Conductor cross-section, flexible , min.
- 0.25 mm²
- Conductor cross-section, rigid , max.
- 2.5 mm²
- Conductor cross-section, rigid , min.
- 0.25 mm²
- Connection system
- PUSH IN
- Number of terminals
- 2 (L,N)
- Wire connection cross section, flexible (input), max.
- 2.5 mm²
Approvals
- Approvals
- CCSAUS, TUEV
- ROHS
- Conform
Dimensions And Weights
- Width
- 90 mm
- Width (inches)
- 3.543 inch
- Height
- 90 mm
- Height (inches)
- 3.543 inch
- Depth
- 60 mm
- Depth (inches)
- 2.362 inch
- Net weight
- 361 g
Electrical Safety (Applied Standards)
- Electrical machine equipment
- Acc. to EN60204
- For use with electronic equipment
- Acc. to EN50178 / VDE0160
- Protection against dangerous shock currents
- Acc. to VDE0106-101
- Protective separation / protection against electrical shock
- VDE0100-410 / acc. to DIN57100-410
- Safety transformers for switch-mode power supplies
- According to EN 61558-2-16
Emc / Shock / Vibration
- Limiting of mains voltage harmonic currents
- EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips), EN 61000-4-11 (Dips)
- Noise emission in accordance with EN55032
- Class B
- Vibration resistance IEC 60068-2-6
- 2.3 g
- Interference immunity test acc. to
- EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips), EN 61000-4-11 (Dips)
- Shock resistance IEC 60068-2-27
- 15 g In all directions
Input
- AC current consumption
- 1.2 A @ 230 V AC / 2.5 A @ 100 V AC
- AC input voltage range
- 85...264 V AC (derating at 100 V AC)
- Connection system
- PUSH IN
- DC current consumption
- 0.4 A @ 370 V DC / 1.35 A @ 120 V DC
- DC input voltage range
- 95¦370 V DC
- Frequency range AC
- 45¦65 Hz
- Input fuse (internal)
- Yes
- Inrush current
- max. 40 A
- Rated input voltage
- 100 - 240 V AC / 120 - 340 V DC
- Recommended back-up fuse
- 2 A / DI, safety fuse6 A, Char. B, circuit breaker2...4 A, Char. C circuit breaker
Classifications
- ETIM 6.0
- EC002540
- ETIM 7.0
- EC002540
- EClass 9.0
- 27-04-07-01
- EClass 9.1
- 27-04-07-01
- EClass 10.0
- 27-04-07-01
Output
- Capacitive load
- unrestricted
- Connection system
- PUSH IN
- Continous output current @ U
- 2 A @ 55°C, 1.25 A @ 70°C
- Nominal output current for U
- 2 A @ 55°C
- Output voltage
- 56...35 V (adjustable via potentiometer on front)
- Ramp-up time
- ‰¤ 100 ms
- Rated output voltage
- 48 V DC ± 1 %
- Residual ripple, breaking spikes
- < 50 mVss @ UNenn, Full Load
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Insulation Coordination
- Insulation voltage input / earth
- 3.5 kV
- Insulation voltage output / earth
- 0.5 kV
- Insulation voltage, input/output
- 4 kV
- Pollution severity
- 2
- Protection class
- II
Connection Data (Output)
- Conductor cross-section, AWG/kcmil , max.
- 12
- Conductor cross-section, AWG/kcmil , min.
- 24
- Conductor cross-section, flexible , max.
- 2.5 mm²
- Conductor cross-section, flexible , min.
- 0.25 mm²
- Conductor cross-section, rigid , max.
- 2.5 mm²
- Conductor cross-section, rigid , min.
- 0.25 mm²
- Connection system
- PUSH IN
- Number of terminals
- 4 (++ / --)
Temperatures
- Operating temperature, max.
- 70 °C
- Operating temperature, min.
- -25 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -25°C...70°C
- Storage temperature
- -40°C...85°C