WEIDMULLER 2580270000-Dropship Automation

WEIDMULLER 2580270000

SKU: DA-274427
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 2580270000 General Data Degree of efficiency 89% Housing version Plastic, protective insulation MTBF >; 750.000 h nach IEC 61709 (SN29500) Mounting position, installation notice Horizontal on DIN rail TS 35, top and bottom 50 mm clearance for free air flow, 10 mm clearance to neighbouring active subassemblies with full load, 5 mm with passive neighbouring subassemblies,...

Additional Information

Part Number
2580270000

General Data

Degree of efficiency
89%
Housing version
Plastic, protective insulation
MTBF
>; 750.000 h nach IEC 61709 (SN29500)
Mounting position, installation notice
Horizontal on DIN rail TS 35, top and bottom 50 mm clearance for free air flow, 10 mm clearance to neighbouring active subassemblies with full load, 5 mm with passive neighbouring subassemblies, direct row mounting with 90% rated load
Operating temperature
-25°C...70°C
Power loss, idling
0.45 W
Power loss, nominal load
10.56 W
Protection against reverse voltages from the load
58¦62 V DC
Protection degree
IP20

Signalling

LED green
Operating voltage OK

Connection Data (Input)

Conductor cross-section, AWG/kcmil , max.
12
Conductor cross-section, AWG/kcmil , min.
24
Conductor cross-section, flexible , min.
0.25 mm²
Conductor cross-section, rigid , max.
2.5 mm²
Conductor cross-section, rigid , min.
0.25 mm²
Connection system
PUSH IN
Number of terminals
2 (L,N)
Wire connection cross section, flexible (input), max.
2.5 mm²

Approvals

Approvals
CCSAUS, TUEV
ROHS
Conform

Dimensions And Weights

Width
90 mm
Width (inches)
3.543 inch
Height
90 mm
Height (inches)
3.543 inch
Depth
60 mm
Depth (inches)
2.362 inch
Net weight
361 g

Electrical Safety (Applied Standards)

Electrical machine equipment
Acc. to EN60204
For use with electronic equipment
Acc. to EN50178 / VDE0160
Protection against dangerous shock currents
Acc. to VDE0106-101
Protective separation / protection against electrical shock
VDE0100-410 / acc. to DIN57100-410
Safety transformers for switch-mode power supplies
According to EN 61558-2-16

Emc / Shock / Vibration

Limiting of mains voltage harmonic currents
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips), EN 61000-4-11 (Dips)
Noise emission in accordance with EN55032
Class B
Vibration resistance IEC 60068-2-6
2.3 g
Interference immunity test acc. to
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips), EN 61000-4-11 (Dips)
Shock resistance IEC 60068-2-27
15 g In all directions

Input

AC current consumption
1.2 A @ 230 V AC / 2.5 A @ 100 V AC
AC input voltage range
85...264 V AC (derating at 100 V AC)
Connection system
PUSH IN
DC current consumption
0.4 A @ 370 V DC / 1.35 A @ 120 V DC
DC input voltage range
95¦370 V DC
Frequency range AC
45¦65 Hz
Input fuse (internal)
Yes
Inrush current
max. 40 A
Rated input voltage
100 - 240 V AC / 120 - 340 V DC
Recommended back-up fuse
2 A / DI, safety fuse6 A, Char. B, circuit breaker2...4 A, Char. C circuit breaker

Classifications

ETIM 6.0
EC002540
ETIM 7.0
EC002540
EClass 9.0
27-04-07-01
EClass 9.1
27-04-07-01
EClass 10.0
27-04-07-01

Output

Capacitive load
unrestricted
Connection system
PUSH IN
Continous output current @ U
2 A @ 55°C, 1.25 A @ 70°C
Nominal output current for U
2 A @ 55°C
Output voltage
56...35 V (adjustable via potentiometer on front)
Ramp-up time
‰¤ 100 ms
Rated output voltage
48 V DC ± 1 %
Residual ripple, breaking spikes
< 50 mVss @ UNenn, Full Load

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Insulation Coordination

Insulation voltage input / earth
3.5 kV
Insulation voltage output / earth
0.5 kV
Insulation voltage, input/output
4 kV
Pollution severity
2
Protection class
II

Connection Data (Output)

Conductor cross-section, AWG/kcmil , max.
12
Conductor cross-section, AWG/kcmil , min.
24
Conductor cross-section, flexible , max.
2.5 mm²
Conductor cross-section, flexible , min.
0.25 mm²
Conductor cross-section, rigid , max.
2.5 mm²
Conductor cross-section, rigid , min.
0.25 mm²
Connection system
PUSH IN
Number of terminals
4 (++ / --)

Temperatures

Operating temperature, max.
70 °C
Operating temperature, min.
-25 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-40 °C
Operating temperature
-25°C...70°C
Storage temperature
-40°C...85°C

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products