Additional Information
- Part Number
- 2456840000
General Data
- Accuracy
- < 0.1 % of measuring range
- Cold-junction compensation error
- ±2.0°C @ -20° C - 70°C
- Configuration
- With FDT/DTM software, or via 7-segment display, push-buttons and rotary encoder on the device itself
- Galvanic isolation
- 4-way isolator;, Input to supply �„ Alarm 1 �„ Alarm 2
- Power consumption
- ‰¤ 3.5 W
- Rail
- TS 35
- Repeat accuracy
- ± 0.05 % of measuring range final value
- Step response time
- 450 ms
- Temperature coefficient
- < 0.02°C of measuring range /°C
- Voltage supply
- 9...60 V DC
Approvals
- ROHS
- Conform
Dimensions And Weights
- Width
- 22.5 mm
- Width (inches)
- 0.886 inch
- Height
- 127.1 mm
- Height (inches)
- 5.004 inch
- Depth
- 113.6 mm
- Depth (inches)
- 4.472 inch
- Net weight
- 150 g
Output (Digital)
- Alarm function
- configurable, Alarm mode: delay, switch on or switch on/off, Top and bottom limit values, window range, Hysteresis adjustable, auto / manual reset
- Number of digital outputs
- 2
- Type
- 2 CO contacts, normal / inverse adjustment, Switching frequency 20 Hz
- Max. switching voltage, DC
- 110 V
- Max. switching voltage, AC
- 240 V
- Rated switching current
- 200mA @ 110Vdc, 6A @ 24Vdc / 240Vac
Connection Data
- Type of connection
- PUSH IN
- Wire connection cross section AWG, min.
- AWG 26
- Wire connection cross section AWG, max.
- AWG 14
- Wire cross-section, solid, min.
- 0.2 mm²
- Wire cross-section, solid, max.
- 2.5 mm²
- Wire connection cross-section, finely stranded, min.
- 0.2 mm²
- Wire connection cross section, finely stranded, max.
- 2.5 mm²
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
- 0.2 mm²
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
- 2.5 mm²
Input
- Number of inputs
- 1
- Sensor
- Thermocouples: B, E, J, K, L, N, R, S, T, U, RTD: PT100, PT200, PT1000, Ni120, Cu10, 2-/3-/4-wire
- Sensor supply
- 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable
- Influence of the sensor cable resistance
- 5 © @ RTD- Kabel
- Input voltage
- configurable, ±150 mV DC, ± 600mV DC, ±30 V DC, ±300 V DC
- Input resistance, voltage
- 2 M©, > 10 M©
- Input current
- configurable, ± 25 mA DC, ±5 A DC
- Input resistance, current
- 40 ©
- Input measurement range
- configurable, Thermocouple type J -100¦+1200°C, Thermocouple type K -200¦+1370°C, PT100 -200¦+850°C
- Cable-length compensation
- < ±0.002 © per cable resistance ©
- Resistance
- 0¦10 k©, 0¦12 k©, 0¦15 k©
- Potentiometer
- 1.2¦500 k©
Classifications
- ETIM 6.0
- EC002654
- ETIM 7.0
- EC002654
- EClass 9.0
- 27-21-01-22
- EClass 9.1
- 27-21-01-22
- EClass 10.0
- 27-21-01-22
Product Information
- Product information
- The devices of the ACT20P-UI-2RCO-XX-x family record current, voltage, potentiometer and temperature sensor signals (mA, A, mV, V, potentiometer, RTD and TC). They have two independent relay outputs which emit an alarm when levels exceed or fall below pre-set limits. Properties Configuration and diagnosis with the FDT/DTM software œWI-Manager�. Manual configuration on the device is performed via the LED display by means of operating buttons and rotary encoders. The dual-channel trip amplifier enables various alarm functions: window alarm, alarm delay, wire break detection, hysteresis and upper / lower limit alarm. The active or passive signal inputs for RTD, TC, potentiometer, voltage and current are fully galvanically isolated. Remote diagnosis: reporting of errors (e.g. cable breaks) via status relay. Operational status and relay status indicated by front panel LEDs. Galvanic 4-way isolation between input, output and supply.
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Insulation Coordination
- EMC standards
- EN 61326-1
- Galvanic isolation
- 4-way isolator;, Input to supply �„ Alarm 1 �„ Alarm 2
- Impulse withstand voltage
- 4 kV (1.2/50 µs)
- Insulation voltage
- 4 kV (input / output)
- Pollution severity
- 2
- Rated voltage
- 300 Veff
- Surge voltage category
- III
Temperatures
- Humidity
- 10¦90 %, no condensation
- Operating temperature, max.
- 70 °C
- Operating temperature, min.
- -20 °C
- Storage temperature, max.
- 70 °C
- Storage temperature, min.
- -20 °C
- Operating temperature
- -20°C...70°C
- Storage temperature
- -20°C...70°C