Additional Information
- Part Number
- 1352970000
General Data
- Colour
- black, orange
- Design
- Installation housing; 2TE, Insta IP 20
- Optical function display
- green = OK; red = arrester is defective - replace
- Protection degree
- IP20
- Rail
- TS 35
- UL 94 flammability rating
- V-0
- Version
- without telecomm. contact
Approvals
- Approvals
- CE, EAC, OEVE
- ROHS
- Conform
Insulation Coordination Acc. To En 50178
- Pollution severity
- 2
- Surge voltage category
- III
Rated Data Iec / En
- Combined pulse U
- 10Â kV
- Discharge current I
- 12.5 kA
- Energy coordination (‰¤10 m)
- Type II, Type III
- Follow-on current extinguishing capability I
- Not available due for technical reasons
- Frequency range, max.
- 60Â Hz
- Frequency range, min.
- 50Â Hz
- Fuse
- 125 A gL >; (if back up fuse >; 125 A)
- Leakage current at U
- 100 µA
- Low voltage network
- Single-phase
- Max. continuous voltage, Uc (AC)
- 600 V
- Number of poles
- 2
- Protection level U
- ‰¤ 2.35 kV
- Rated voltage (AC)
- 480Â V
- Requirements category acc. to IEC 61643-11
- Type II, Type III
- Requirements class, acc. to EN 61643-11
- T2, T3
- Response time
- ‰¤ 25 ns
- Short-circuit current rating I
- 25Â kA
- Signalling contact
- No
- Standards
- IEC61643-11, EN61643-11
- Temporary surge voltage (over-voltage) - TOV
- 820Â V
- Voltage type
- AC
Dimensions And Weights
- Width
- 35.6Â mm
- Width (inches)
- 1.402Â inch
- Height
- 94Â mm
- Height (inches)
- 3.701Â inch
- Depth
- 69Â mm
- Depth (inches)
- 2.717Â inch
- Mounting dimension - height
- 75Â mm
- Net weight
- 290Â g
Connection Data
- Wire connection method
- Screw connection
- Type of connection
- Screw connection
- Stripping length, rated connection
- 15Â mm
- Tightening torque, min.
- 2Â Nm
- Tightening torque, max.
- 3Â Nm
- Clamping range, rated connection
- 16 mm²
- Clamping range, min.
- 1.5 mm²
- Clamping range, max.
- 35 mm²
- Wire cross-section, solid, min.
- 1.5 mm²
- Wire cross-section, solid, max.
- 16 mm²
- Wire connection cross-section, finely stranded, min.
- 1.5 mm²
- Wire connection cross section, finely stranded, max.
- 25 mm²
- Conductor cross-section, flexible, AEH (DIN 46228-1), min.
- 1.5 mm²
- Conductor cross-section, flexible, AEH (DIN 46228-1), max.
- 50 mm²
- Connection cross-section, stranded, min.
- 1.5 mm²
- Connection cross-section, stranded, max.
- 50 mm²
Tender Specification Sheets
- Long specification
- Multi-pole lightning arrestor according to the requirements of Class II/III acc. to IEC 61643-11, EN61643-11:2013. Consisting of V0 material, the arrestor provides overvoltage protection in applications acc. to IEC 61643-12. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU II 2 600 V/25 kA is used in the single-phase mains network. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. Rated voltage: 600 VAC In/max (8/20 µs): 12.5/25 kA protection level < 2.35 kV 25 kA short-circuit strength with max. back-up fuse of 125 A gl Type: Weidmüller VPU II 2 600 V/25 kA Order No. 1352970000 or equivalent
- Short specification
- Class II arrester with In/Imax: 12.5/25 kA suitable for single-phase 600 V TN-C mains systems. Protection level < 2.35 kV. Type: Weidmüller VPU II 2 600 V/25 kA Order no. 1352970000 or equivalent
Classifications
- ETIM 6.0
- EC000941
- ETIM 7.0
- EC000941
- EClass 9.0
- 27-13-08-05
- EClass 9.1
- 27-13-08-05
- EClass 10.0
- 27-13-08-05
- UNSPSC
- 30-21-19-21
Temperatures
- Humidity
- 5 - 95% rel. humidity
- Operating temperature, max.
- 70 °C
- Operating temperature, min.
- -40 °C
- Storage temperature, max.
- 80 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -40 °C...70 °C
- Storage temperature
- -40 °C...80 °C