Additional Information
- Part Number
- 1235830000
Rated Data Acc. To Ul 1059
- Institute (cURus)
- cURus
- Certificate No. (cURus)
- E60693
- Rated voltage (Use group B / UL 1059)
- 300 V
- Rated voltage (Use group D / UL 1059)
- 300 V
- Rated current (Use group B / UL 1059)
- 10 A
- Rated current (Use group D / UL 1059)
- 10 A
- Wire cross-section, AWG, min.
- AWG 26
- Wire cross-section, AWG, max.
- AWG 16
- Reference to approval values
- Specifications are maximum values, details - see approval certificate.
Approvals
- Approvals
- cURus, EAC
- ROHS
- Conform
- UL File Number Search
- E60693
Dimensions And Weights
- Width
- 34.38 mm
- Width (inches)
- 1.354 inch
- Height
- 9.3 mm
- Height (inches)
- 0.366 inch
- Depth
- 34.6 mm
- Depth (inches)
- 1.362 inch
- Net weight
- 7.2 g
Rated Data Acc. To Iec
- Tested acc. to standard
- IEC 60664-1, IEC 61984
- Rated current, min. number of poles (Tu=20°C)
- 17.5 A
- Rated current, max. number of poles (Tu=20°C)
- 17.5 A
- Rated current, min. number of poles (Tu=40°C)
- 17.5 A
- Rated current, max. number of poles (Tu=40°C)
- 16.3 A
- Rated voltage for surge voltage class / pollution degree II/2
- 320 V
- Rated voltage for surge voltage class / pollution degree III/2
- 160 V
- Rated voltage for surge voltage class / pollution degree III/3
- 160 V
- Rated impulse voltage for surge voltage class/ pollution degree II/2
- 2.5 kV
- Rated impulse voltage for surge voltage class/ pollution degree III/2
- 2.5 kV
- Rated impulse voltage for surge voltage class/ contamination degree III/3
- 2.5 kV
- Short-time withstand current resistance
- 3 x 1s with 76 A
Material Data
- Insulating material
- PA 66 GF 30
- Colour
- orange
- Colour of operational elements
- black
- Material of operational elements
- PPA GF
- Colour chart (similar)
- RAL 2000
- Insulating material group
- II
- Comparative Tracking Index (CTI)
- ? 550
- Insulation strength
- ? 108 ?
- UL 94 flammability rating
- V-0
- GWFI
- 960 °C
- Contact material
- Copper alloy
- Contact surface
- tinned
- Layer structure of plug contact
- 4-8 µm Sn
- Storage temperature, min.
- -25 °C
- Storage temperature, max.
- 55 °C
- Max. relative humidity during storage
- 80 %
- Operating temperature, min.
- -50 °C
- Operating temperature, max.
- 120 °C
- Temperature range, installation, min.
- -25 °C
- Temperature range, installation, max.
- 120 °C
Classifications
- ETIM 6.0
- EC002638
- ETIM 7.0
- EC002638
- EClass 9.0
- 27-44-03-09
- EClass 9.1
- 27-44-03-09
- EClass 10.0
- 27-44-03-09
System Parameters
- Product family
- OMNIMATE Signal - series BC/SC 3.81
- Type of connection
- Field connection
- Wire connection method
- PUSH IN, Tension-clamp connection
- Pitch in mm (P)
- 3.81 mm
- Pitch in inches (P)
- 0.15 inch
- Conductor outlet direction
- 180°
- Number of poles
- 9
- L1 in mm
- 30.48 mm
- L1 in inches
- 1.2 inch
- Number of rows
- 1
- Pin series quantity
- 1
- Rated cross-section
- 1 mm²
- Touch-safe protection acc. to DIN VDE 57 106
- Safe from finger touch
- Touch-safe protection acc. to DIN VDE 0470
- IP 20
- Volume resistance
- 6.00 m?
- Can be coded
- Yes
- Stripping length
- 9 mm
- Actuating force actuating element, max.
- 40 N
- Screwdriver blade
- 0.4 x 2.5
- Screwdriver blade standard
- DIN 5264
- Plugging cycles
- 25
- Plugging force/pole, max.
- 8 N
- Pulling force/pole, max.
- 7 N
Packing
- Packaging
- Box
- VPE length
- 170 mm
- VPE width
- 120 mm
- VPE height
- 50 mm
Notes
- Notes
- Additional colours on request Crimp shape A for wire-end ferrules with crimping tools PZ 1,5 (order no. 9005990000) or PZ 6/5 (order no. 9011460000) for larger wire cross-sections recommended. Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. Conductors suitable for connection: 1.5 mm² with wire-end ferrule with plastic collar, DIN 46 228/1, with a rated voltage of 125V/2.5 kV with III/3 or 250 V/2.5 kV with II/2
- IPC conformity
- Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.
Conductors Suitable For Connection
- Clamping range, min.
- 0.14 mm²
- Clamping range, max.
- 1.5 mm²
- Wire connection cross section AWG, min.
- AWG 26
- Wire connection cross section AWG, max.
- AWG 16
- Solid, min. H05(07) V-U
- 0.14 mm²
- Solid, max. H05(07) V-U
- 1.5 mm²
- Flexible, min. H05(07) V-K
- 0.14 mm²
- Flexible, max. H05(07) V-K
- 1.5 mm²
- W. plastic collar ferrule, DIN 46228 pt 4, min.
- 0.25 mm²
- W. plastic collar ferrule, DIN 46228 pt 4, max.
- 1 mm²
- W. wire end ferrule, DIN 46228 pt 1, min.
- 0.25 mm²
- W. wire end ferrule, DIN 46228 pt 1, max.
- 1.5 mm²
- Plug gauge in accordance with EN 60999 a x b; ø
- 2.4 mm x 1.5 mm; 1.9mm
- Reference text
- The outside diameter of the plastic collar should not be larger than the pitch (P).
- Max. clamping range
- 1.5 mm²
Rated Data Acc. To Csa
- Rated voltage (Use group B / CSA)
- 300 V
- Rated voltage (Use group C / CSA)
- 50 V
- Rated voltage (Use group D / CSA)
- 300 V
- Rated current (Use group B / CSA)
- 11 A
- Rated current (Use group C / CSA)
- 11 A
- Rated current (Use group D / CSA)
- 11 A
- Wire cross-section, AWG, min.
- AWG 26
- Wire cross-section, AWG, max.
- AWG 16