WEIDMULLER 1063940000-Dropship Automation

WEIDMULLER 1063940000

SKU: DA-432330
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 1063940000 Further Details Of Approvals GOST certificate GOST-Zertifikat Protection Ex - Data ATEX - dust labelling II 1 D Ex ia IIIC T135°C ¦T85°C Da ATEX - gas labelling II 1 G Ex ia IIC T4¦ T6 Ga IECEx - dust labelling II 1 D Ex ia IIIC T135°C ¦T85°C Da IECEx - gas labelling II...

Additional Information

Part Number
1063940000

Further Details Of Approvals

GOST certificate
GOST-Zertifikat

Protection Ex - Data

ATEX - dust labelling
II 1 D Ex ia IIIC T135°C ¦T85°C Da
ATEX - gas labelling
II 1 G Ex ia IIC T4¦ T6 Ga
IECEx - dust labelling
II 1 D Ex ia IIIC T135°C ¦T85°C Da
IECEx - gas labelling
II 1 G Ex ia IIC T4¦ T6 Ga
Input power, max. P
0.75 W
Input voltage, max. U
55 V
Internal capacity, max. C
1 nF
Internal inductance, max. L
0 µH
Temperature class T4/135°C (-40°C ... +120°C) li
300 mA
Temperature class T5/100°C (-40° C ... +85°C) li
300 mA
Temperature class T6/85°C (-40°C ... +70°C) li
300 mA

General Data

Colour
Light Blue
Design
Terminal
Isolating function
No
Optical function display
No
Protection degree
IP20
Rail
TS 35
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
Surge protection for measurement and control

Probability Of Failure

›ges
43
MTTF
2,655 years
PFH in 1*10
0.9
SFF
97.91 %
SIL PAPER
SIL Paper
SIL in compliance with IEC 61508
3

Approvals

Approvals
CE, CSAEX, DEKRAATEX, EAC, FUSAFETY, IECEXDEK, OEVE
ROHS
Conform

Insulation Coordination Acc. To En 50178

Pollution severity
2
Surge voltage category
III

Rated Data Iec / En

Dielectric strength at FG against PE
‰¥ 500 V
Discharge current I
2.5 kA
Discharge current, max. (8/20 µs)
10 kA
Input voltage, max. U
55 V
Insertion loss
6.6 MHz
Lightning test current I
1 kA
Lightning test current, I
0.5 kA
Max. continuous voltage, Uc (AC)
60 V
Max. continuous voltage, Uc (DC)
85 V
Number of poles
1
Overload - failure mode
Modus 2
Protection level U
< 200 V
Pulse-reset capacity
‰¤ 20 ms
Rated current I
300 mA
Rated voltage (AC)
48 V
Rated voltage (DC)
68 V
Requirements category acc. to IEC 61643-21
C2, C3, D1
Signal transmission properties (-3 dB)
5.2 MHz
Standards
IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Surge current-carrying capacity C2
2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3
10 A 10/1000 µs
Surge current-carrying capacity D1
1 kA 10/350 ¼s
Voltage type
AC/DC
Volume resistance
1.8 © 10 %

Dimensions And Weights

Width
12.4 mm
Width (inches)
0.488 inch
Height
76 mm
Height (inches)
2.992 inch
Depth
58.5 mm
Depth (inches)
2.303 inch
Net weight
39.8 g

Csa Protection Data

Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input current, max. I
300 mA
Input voltage, max. U
55 V
Internal capacity, max. C
1 nF
Internal inductance, max. L
0 µH

Connection Data

Type of connection
Screw connection
Tightening torque, min.
0.5 Nm
Tightening torque, max.
0.8 Nm
Clamping range, min.
0.5 mm²
Clamping range, max.
4 mm²
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
4 mm²
Connection cross-section, stranded, min.
0.5 mm²
Connection cross-section, stranded, max.
4 mm²

Rated Data Ul

UL certificate
UL Zertifikat

Tender Specification Sheets

Long specification
Surge protection in a one piece, 12.4 mm wide DIN rail module for two binary, potential-free signal circuits with 48 V UC. When the terminal is fitted, there is a simultaneous sparkover gap created to the high-impedance earth between the mounting rail (earth) and the reference potential (ground) of the protective switch. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. ATEX version. Tested to Ex area ignition protection types: Ex ia IIC / Ex iaD
Short specification
Surge protection in a one piece, 12.4 mm wide DIN rail module for two binary, potential-free signal circuits. Version: 48 V UC ATEX version.

Classifications

ETIM 6.0
EC000943
ETIM 7.0
EC000943
EClass 9.0
27-13-08-07
EClass 9.1
27-13-08-07
EClass 10.0
27-13-08-07
UNSPSC
30-21-19-21

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Temperatures

Humidity
5...96 %
Operating temperature, max.
70 °C
Operating temperature, min.
-40 °C
Storage temperature, max.
80 °C
Storage temperature, min.
-40 °C
Operating temperature
-40°C...70°C
Storage temperature
-40°C...80°C

Ratings Iecex/Atex/Cul

ATEX certificate
ATEX Certificate
IEC Ex certificate
IECEX Zertifikat
CUL certificate
cUL Certificate

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products