- Ambient temperature (operation)
- -25 É +60¡C
- Ambient temperature (storage)
- -40 É +85¡C
- Protection type
- IP67
- Protection class
- III
- Operating altitude
- ?1000 É 2000 m; Air pressure: 1080 É 795 hPa
- Relative humidity (without condensation)
- 95 %
- Vibration resistance
- 5g per IEC 60068-2-6
- Shock resistance
- Short-term: 50g/11 ms/half-sine per IEC 60068-2-27; Long-term: 30g/6 ms/half-sine per IEC 60068-2-29
- EMC immunity to interference
- Per EN 61000-6-2
- EMC emission of interference
- Per EN 61000-6-4
- Connection technology: inputs/outputs
- 4 x M12 socket; 5-pole; A-coded
- Connection technology: field supply
- 1 x M12 plug; 4-pole; A-coded; 1 x M12 socket; 4-pole; A-coded
- Connection technology: system supply
- 1 x M12 socket; 4-pole; A-coded; 1 x M12 plug; 4-pole; A-coded
- Connection technology: system bus
- 1 x M12 socket, 5-pole, B-coded, shielded; 1 x M12 plug, 5-pole, B-coded, shielded
- Connection requirement (permissible cable length)
- 30 m
- Connection requirement (permissible cable type)
- Analog inputs: unshielded
- Width
- 50 mm / 1.969 inches
- Height
- 35.7 mm / 1.406 inches
- Depth
- 117 mm / 4.606 inches
- Housing material
- Polyamide (PA), Makrolon (address switch cover), flammability per UL94-V0, halogen/silicon-free
- Fire load
- 0.009 MJ
- Weight
- 280.000 g
- Conformity marking
- CE
- Encapsulation
- Polyurethane (PUR), halogen/silicon-free
- Number of analog inputs
- 4
- Total number of channels (module)
- 4
- Signal type
- Resistance measurement || Potentiometer positions
- Signal type (configurable)
- Yes
- Sensor connection
- 4 x (2-wire, 3-wire, 4-wire); External shield via knurled nut
- Resolution [bit]
- 16 bits
- Process data width
- 8-byte data + status
- Parameterizable functions
- I/O diagnostics (per module): Undervoltage (ULS + UA) || I/O diagnostics (per channel): Measurement range overflow/underflow; Limit value violation (min./max.) || Online simulation (per module): Diagnostics || Online simulation (per channel): Lock/Unlock; Simulation value: according to measurement range; Diagnostics || Measurement range (per channel): Parameterizable || Limiting values (per channel): Min./Max. || Linearization (per channel)): Linear/Pt/Ni/Ni TK 5000/Ni TK 6720 || Integration time (per channel): 2/ 4/ 8/ 16.7/ 20/ 30/ 60/ 120 ms
- Protection
- Reverse voltage protection for ULS + Uo
- Resolution (over entire range)
- 0.05¡C / 0.05 ?/ 0.25 ? / 0.005 %
- Measurement error (reference temperature)
- 25¡C
- Measurement error, deviation (max.) from the upper-range value
- 0.1 %
- Temperature coefficient
- ±0.001 % of the measurement range/ K
- Measuring current (typ.)
- < 0.5 mA
- Sensor types
- Pt100; Configurable: Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000; Potentiometer setting 0 É 100 %: 1 k?, 4 k?
- Temperature range
- -200 É + 850¡C (Pt), -60 É +250¡C (Ni)
- Measurement range
- Pt100/ Pt200/ Pt500/ Pt1000, Ni100/ Ni120/ Ni1000; 1 k? / 4 k?; 0 É 100 % setting angle (for 1 k? and 4 k?)
- Supply voltage (system and sensor)
- 24 VDC(-25 É +30 %); Logic and sensors (ULS)
- Current consumption (system and sensor)
- 40 mA
- Supply voltage (field)
- 24 VDC (-25 É +30 %); Actuators (UA), for transmission only
- Current consumption, field supply (module with no external load)
- 4 mA
- Isolation
- 500 V supply/system bus
- Indicators
- LED (F) red: Error status; LED (SB) green/red/orange: System bus status; LED (ULS, UA) green: Power supply status; LED (Ch1 É Ch4) yellow: Status AI 1 É AI 4; LED (Er1 É Er4) red: Error AI 1 É AI 4; Non-retentive displays
- Current carrying capacity (supply connections)
- 8 A
- Sampling repetition time
- Number of active channels x conversion time x 2
- Integration time
- 2 É 120 ms
- Monotonicity without error codes
- Yes
- Conversion method (2)
- SigmaDelta
- Conversion time (2)
- 1 / Input sampling frequency (s)
- Maximum temporary deviation
- 0.05¡C
- Maximum error over the full temperature range
- < 2¡C
- Repeat accuracy
- 0.05¡C
- Packaging type
- Box
- Country of origin
- DE
- GTIN
- 4045454545253
- Customs tariff number
- 85389099990