Output
- Output Volt Amp Capacity (VA)
- 60000
- Output kVA Capacity (kVA)
- 60
- Output Watt Capacity (Watts)
- 54000
- Output kW Capacity (kW)
- 54
- Power Factor
- 0.9
- Crest Factor
- 3:1
- Nominal Voltage Details
- Output THD full resistive load: <1.5%; Output THD non-linear load: <4%; Max DC offset: ±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included
- Frequency Compatibility
- 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
- Frequency Compatibility Details
- Auto-selectable, user adjustable
- Output Receptacle Details
- Output wiring: 3P, N, E
- Output Circuit Breakers
- 300A 3 pole magnetic breaker
- Output AC Waveform (AC Mode)
- Pure Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Output Capacity Details
- OVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less
- Nominal Output Voltage(s) Supported
- 120/208V 3-PH Wye; 127/220V 3-PH Wye
- Output Receptacles
- Hardwire
- Output Voltage Regulation
- ONLINE, FREQUENCY CONVERSION, BATTERY MODE: 208/120, 220/127 ±1% typical (balanced load); ±2% typical (unbalanced load); ECONOMY MODE: 208/120, 220/127 ±15V; BYPASS MODE: +15% (default, adjustable to +10%, +15% or +20%), -20% (default, adjustable to -10%, -20%, -30%)
- Output Frequency Regulation
- ONLINE MODE: Output frequency is ±0.05Hz of input frequency when input is within ±4Hz* of the configured 50/60Hz output setting; Output frequency is ±0.05Hz the configured 50/60Hz output setting when input is outside ±4Hz* of the configured 50/60Hz output setting; BATTERY MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; FREQUENCY CONVERTER MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; ECONOMY MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (UPS switches to Online mode if frequency goes outside of this range); BYPASS MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (switches to STANDBY mode if frequency goes outside of this range). *The TRACKING RANGE is factory set to ±4Hz and is user adjustable to ±1Hz, ±2Hz or ±4Hz; The selected TRACKING RANGE setting controls frequency output tolerances as described above in Online, Economy and Bypass modes
- Output Amp Capacity
- Output Amp Capacity 167A (208/120V); 157A (220/127V)
- Individually Controllable Load Banks
- No
- Modular Upgrade Options
- Includes 3 SV20PM 20kVA power modules; Up to 1 additional SV20PM 20kVA power module can be added for additional capacity or enhanced N+1 redundancy; Add 1 SV20PM for 80kVA capacity (or 60kVA with N+1)
Input
- Rated input current (Maximum Load)
- SV60KM3P0B 60kVA Configuration: 180A; Maximum 80kVA Configuration: 240A; 306A maximum inrush current
- Nominal Input Voltage(s) Supported
- 120/208V 3-PH Wye; 127/220V 3-PH Wye
- Nominal Input Voltage Description
- Set of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, G) inputs from two separate power sources
- UPS Input Connection Type
- Hardwire
- Input Circuit Breakers
- MAIN and ALTERNATE AC inputs are each protected by 300A 3 pole magnetic breakers
- Input Phase
- 3-Phase
- Input Frequency
- 40 to 70Hz (online mode); 50/60Hz Auto-selectable
- Power Factor (Input)
- Greater than 0.99 (full load)
- THDi
- Less than 2% (full linear load)
Battery
- Full Load Runtime (min.)
- No internal batteries and external batteries are required to operate
- Half Load Runtime (min.)
- No internal batteries and external batteries are required to operate
- Expandable Battery Runtime
- Extended runtime is available with the addition of ±120VDC external battery packs (sold separately); Recommended 3 pole, 400A, 250VDC breaker rating for external battery system
- External Battery Pack Compatibility
- BP240V370 ; BP240V370NB ; EBP240V2501 ; EBP240V2501NB ; EBP240V2502 ; EBP240V2502NB ; EBP240V3501 ; EBP240V3501NB ; EBP240V3502 ; EBP240V3502NB ; EBP240V5001 ; EBP240V5001NB ; EBP240V5002 ; EBP240V5002NB ; EBP240V6002 ; EBP240V6002NB ; EBP240V6003 ; EBP240V6003NB
- Expandable Runtime Description
- External battery pack wiring is contractor supplied.
- DC System Voltage (VDC)
- ±120VDC
- Battery Recharge Rate (Included Batteries)
- User selectable charging current of 1A to 24A (2A factory setting); Recharge rate for internal batteries is 4.6 hours to 90% capacity (7A charging current)
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- Online, double-conversion power conditioning
- Overvoltage Correction
- Maintains continuous output in online mode, without using battery power, during overvoltages to 253V (Ph-Ph), reducing output to within 1% of selected 208/120V, 220/127V nominal output voltage
- Undervoltage Correction
- Maintains continuous output in online mode, without using battery power, during brownout/undervoltage conditions to 156V (Ph-Ph) at full load and to 121V (Ph-Ph) at 70% output load or less, increasing output to within 1% of selected 208/120V or 220/127V nominal output voltage
User Interface, Alerts & Controls
- Front Panel LCD Display
- 145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions
- Switches
- Front panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch
- Alarm Cancel Operation
- Audible alarms can be muted using on-screen prompts
- Audible Alarm
- Unique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm)
- LED Indicators
- Front panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red)
Surge / Noise Suppression
- EMI / RFI AC Noise Suppression
- Yes
- AC Suppression Joule Rating
- 2496
- AC Suppression Joule Rating Details
- 2496 joules (Ph-Ph), 2496 joules (Ph-N), 1872 joules (N-E)
- AC Suppression Response Time
- Instantaneous
Physical
- Cooling Method
- Fans
- Installation Form Factors Supported with Included Accessories
- Tower
- Primary Form Factor
- Tower
- Primary UPS Depth (mm)
- 1,100
- Primary UPS Height (mm)
- 2,010
- Primary UPS Width (mm)
- 600
- Shipping Dimensions (hwd / in.)
- 85.62 x 29.52 x 48.03
- Shipping Weight (lbs.)
- 991.00
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 79.13 x 23.62 x 43.3
- UPS Power Module Weight (kg)
- 376.94
- UPS Power Module Weight (lbs.)
- 831
Environmental
- Operating Temperature Range
- 0° to +40°C (+32° to +104°F); De-rates to 90% capacity at 35°C / 95°F and 80% capacity at 40°C / 104°F
- Storage Temperature Range
- -15° to +60°C (+5° to +140°F)
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 18223
- AC Economy Mode BTU / Hr. (Full Load)
- 715
- AC Economy Mode Efficiency Rating (100% Load)
- 99%
- Audible Noise
- Less than 73 DBA front-side, 1m
- Operating Elevation (m)
- Up to 1000m (At elevations over 1000m, output de-rates by 1% per 100m)
Communications
- Network Management Cards
- WEBCARDLX ; MODBUSCARDSV ; RELAYCARDSV
- Network Monitoring Port Description
- Includes pre-installed Tripp Lite WEBCARDLX network interface
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- DB9 cabling included
- SNMP Compatibility
- Includes pre-installed WEBCARDLX network interface card
- Communications Interface
- DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface
Line / Battery Transfer
- Transfer Time
- No transfer time (0 ms.) in online, double-conversion mode; Less than 20 ms. transfer time in economy mode
- Low Voltage Transfer to Battery Power (Setpoint)
- Maintains continuous operation without using battery power during brownout/undervoltage conditions to to 156V (Ph-Ph) Full load or 121V (Ph-Ph) 70% load or less; Below the low transfer voltage point, output is maintained utilizing reserve battery power
- High Voltage Transfer to Battery Power (Setpoint)
- Maintains continuous operation without using battery power during overvoltages to 253V (Ph-Ph), reducing output within 1% of nominal; Above this point, output is maintained utilizing reserve battery power
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Automatic inverter bypass; Hot swappable batteries
- Green Energy-Saving Features
- Greater than 95% efficiency - GREEN UPS; High efficiency economy mode operation; Schedulable daily hours of economy mode operation
Certifications
- UPS Certifications
- Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
- UPS Certification Details
- UL1778: 2014 5th Edition; CSA C22.2 No. 107.3.14; FCC Part 15 Class A
Warranty
- Product Warranty Period (U.S. & Canada)
- 1-year limited warranty