Additional Information
- Part Number
- SU2200RTXL2UA
- UPC
- 037332042224
Overview
- UPC Code
- 037332042224
- UPS Type
- On-Line
Output
- Output Volt Amp Capacity (VA)
- 2200
- Output kVA Capacity (kVA)
- 2.2
- Output Watt Capacity (Watts)
- 1600
- Output kW Capacity (kW)
- 1.6
- Power Factor
- 0.7
- Crest Factor
- 3:1
- Nominal Voltage Details
- 120V default
- Frequency Compatibility
- 50 / 60 Hz
- Frequency Compatibility Details
- Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
- Output Voltage Regulation (Line Mode)
- +/- 2%
- Output Voltage Regulation (Economy Line Mode)
- +/- 10%
- Output Voltage Regulation (Battery Mode)
- +/- 2%
- Load Management Receptacles
- Two switchable three-outlet 5-15/20R load banks
- Output AC Waveform (AC Mode)
- Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Output Capacity Details
- OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
- Nominal Output Voltage(s) Supported
- 110V; 120V
- Output Receptacles
- (6) 5-15/20R; (1) L5-20R
- Individually Controllable Load Banks
- Yes
Input
- Rated input current (Maximum Load)
- 16A
- Nominal Input Voltage(s) Supported
- 110V AC; 120V AC
- UPS Input Connection Type
- 5-20P
- Input Circuit Breakers
- 30A
- UPS Input Cord Length (ft.)
- 10
- UPS Input Cord Length Details
- Built-in
- Recommended Electrical Service
- 20A 120V
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 4.5 min. (1600w)
- Half Load Runtime (min.)
- 14 min. (800w)
- Expandable Battery Runtime
- Extended runtime supported via optional external battery packs
- External Battery Pack Compatibility
- BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
- Expandable Runtime Description
- BP48V24-2U (limit 2 w/ 48VDCSPLITTER)
- DC System Voltage (VDC)
- 48
- Battery Recharge Rate (Included Batteries)
- Less than 6 hours from 10% to 80% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge
- RBC94-2U
- Battery Access
- Front panel battery access door
- Battery Replacement Description
- Hot-swappable, user replaceable sealed, flame retardant, non-spillable batteries
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- Online, double-conversion power conditioning
- Overvoltage Correction
- 2% output voltage regulation during overvoltages to 150
- Undervoltage Correction
- 2% output voltage regulation during undervoltages to 80
- Severe Undervoltage Correction
- 2% output voltage regulation during undervoltages to 65 (under 70% load only)
User Interface, Alerts & Controls
- Switches
- 2 switches control off/on power status and alarm-cancel/self-test operation
- Alarm Cancel Operation
- Power-fail alarm can be silenced using alarm-cancel switch
- Audible Alarm
- Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
- LED Indicators
- 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 570
- UPS AC Suppression Response Time
- Instantaneous
- UPS Dataline Suppression
- 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
- EMI / RFI AC Noise Suppression
- Yes
Physical
- Cooling Method
- Fan
- Included Mounting Accessory Description
- Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
- Installation Form Factors Supported with Included Accessories
- 4 post 19 inch rackmount
- Installation Form Factors Supported with Optional Accessories
- 2 post rackmount (2POSTRMKITWM); 2-4 post front rail rackmount (UPSHDEARKIT); 4 post rackmount short-depth (4POSTRAILKITWM); Tower (2-9USTAND); Wallmount (2POSTRMKITWM)
- Minimum Required Rack Depth with External Battery Pack (cm)
- 66
- Minimum Required Rack Depth with External Battery Pack (in.)
- 26
- Minimum Required Rack Depth without External Battery Pack (cm)
- 61
- Minimum Required Rack Depth without External Battery Pack (in.)
- 24
- Optional Mounting Accessory Notes
- Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
- Primary Form Factor
- Rackmount
- Primary UPS Depth (mm)
- 483
- Primary UPS Height (mm)
- 89
- Primary UPS Width (mm)
- 445
- Rack Height
- 2U
- Shipping Dimensions (hwd / in.)
- 9.10 x 20.10 x 23.30
- Shipping Weight (lbs.)
- 62.00
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 3.5 x 17.5 x 19
- UPS Power Module Weight (kg)
- 21.50
- UPS Power Module Weight (lbs.)
- 47.4
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 816
- AC Economy Mode BTU / Hr. (Full Load)
- 169
- Battery Mode BTU / Hr. (Full Load)
- 889
- AC Economy Mode Efficiency Rating (100% Load)
- 94%
- Audible Noise
- < 45dB at 1m
Communications
- Network Monitoring Port Description
- Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- USB and DB9 cabling included
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Communications Interface
- USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Line / Battery Transfer
- Transfer Time
- No transfer time (0 ms.) in online, double-conversion mode
- Low Voltage Transfer to Battery Power (Setpoint)
- 80V (100% load), 65V ( <70% load)
- High Voltage Transfer to Battery Power (Setpoint)
- 150
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Automatic inverter bypass; Hot swappable batteries
- Green Energy-Saving Features
- High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
Certifications
- UPS Certifications
- Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico)
- $250,000 Ultimate Lifetime Insurance