Additional Information
- Part Number
- SMX1050SLT
- UPC
- 037332124548
Overview
- UPC Code
- 037332124548
- UPS Type
- Line-Interactive
Output
- Output Volt Amp Capacity (VA)
- 1050
- Output kVA Capacity (kVA)
- 1.05
- Output Watt Capacity (Watts)
- 650
- Nominal Voltage Details
- 230V nominal output in battery mode
- Frequency Compatibility
- 50 / 60 Hz
- Frequency Compatibility Details
- Automatic frequency selection
- Output Voltage Regulation (Line Mode)
- -9%, +5%
- Output Voltage Regulation (Battery Mode)
- +/- 5%
- Included Output Power Cables
- Includes 2 C13 to C14 output power cables
- Hot-Swap PDU options
- PDUBHV10 (2U / 8 C13 outlets)
- Output AC Waveform (AC Mode)
- Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Nominal Output Voltage(s) Supported
- 220V; 230V; 240V
- Output Receptacles
- (8) C13
- Individually Controllable Load Banks
- No
Input
- Rated input current (Maximum Load)
- 2.8A (230V), 3.0A (220V), 2.7A (240V)
- Nominal Input Voltage(s) Supported
- 220V AC; 230V AC; 240V AC
- UPS Input Connection Type
- C14 inlet
- UPS Input Connection Description
- IEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 7 min. (650w)
- Half Load Runtime (min.)
- 20 min. (325w)
- DC System Voltage (VDC)
- 24
- Battery Recharge Rate (Included Batteries)
- Less than 8 hours from 10% to 90% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge
- RBC24-SLT
- Battery Access
- Battery access door
- Battery Replacement Description
- Hot-swappable, user replaceable batteries
- Expandable Runtime
- No
Voltage Regulation
- Voltage Regulation Description
- Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 182 to 278 (230v), 190 to 290 (240v), 174 to 266 (220v)
- Overvoltage Correction
- Voltage reduction of 12% applies when input is 244 to 278 (230v), 254 to 290 (240v), 232 to 266 (220v)
- Undervoltage Correction
- Voltage boost of 14% applies when input is 182 to 206 (230v), 190 to 216 (240v), 174 to 198 (220)
User Interface, Alerts & Controls
- Switches
- 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection
- Alarm Cancel Operation
- Power-fail alarm can be silenced using alarm-cancel switch
- Audible Alarm
- Audible alarm indicates power failure and overload conditions
- LED Indicators
- 9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 350
- UPS AC Suppression Response Time
- Instantaneous
- UPS Dataline Suppression
- 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
- EMI / RFI AC Noise Suppression
- Yes
Physical
- Cooling Method
- Fan
- Installation Form Factors Supported with Included Accessories
- Tower
- Primary Form Factor
- Tower
- Primary UPS Depth (mm)
- 335
- Primary UPS Height (mm)
- 259
- Primary UPS Width (mm)
- 173
- Shipping Dimensions (hwd / in.)
- 14.00 x 9.75 x 18.50
- Shipping Weight (lbs.)
- 38.60
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 10.2 x 6.8 x 13.2
- UPS Power Module Weight (kg)
- 16.33
- UPS Power Module Weight (lbs.)
- 36
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 52
- Battery Mode BTU / Hr. (Full Load)
- 521
- AC Mode Efficiency Rating (100% Load)
- 94%
- Operating Elevation (ft.)
- Up to 10,000 ft
- Audible Noise
- Audible Noise < 50 dBA at Front Side 1 Meter
- Operating Elevation (m)
- Up to 3000m
Communications
- Network Management Cards
- SNMPWEBCARD ; WEBCARDLX ; RELAYIOCARD
- Network Monitoring Port Description
- Supports detailed monitoring of UPS and site power conditions
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- USB and DB9 cabling included
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Communications Interface
- USB; DB9 Serial; Slot for SNMP/Web interface
Line / Battery Transfer
- Transfer Time
- 4-8 milliseconds
- Low Voltage Transfer to Battery Power (Setpoint)
- 174V (220V), 182V (230V) or 190V (240V)
- High Voltage Transfer to Battery Power (Setpoint)
- 266V (220V), 278V (230V) or 290V (240V)
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Hot swappable batteries
Certifications
- UPS Certifications
- CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Meets FCC Part 15 Category B (EMI)
- UPS Certification Details
- CE / IEC 62040
Warranty
- Product Warranty Period (International)
- 2-year limited warranty