Additional Information
- Part Number
- SMART1200XLHGL
- UPC
- 037332192202
Overview
- UPC Code
- 037332192202
- UPS Type
- Line-Interactive
Output
- Output Volt Amp Capacity (VA)
- 1000
- Output kVA Capacity (kVA)
- 1
- Output Watt Capacity (Watts)
- 750
- Power Factor
- 0.8
- Frequency Compatibility
- 60 Hz
- Output Voltage Regulation (Line Mode)
- -18%, +8%
- Output Voltage Regulation (Battery Mode)
- 115V (+/- 5%)
- Output Receptacle Details
- Hospital grade output receptacles
- Output AC Waveform (AC Mode)
- Sine wave
- Output AC Waveform (Battery Mode)
- PWM sine wave
- Nominal Output Voltage(s) Supported
- 115V; 120V
- Output Receptacles
- (4) 5-15R
- Individually Controllable Load Banks
- No
Input
- Rated input current (Maximum Load)
- 9.2A
- Nominal Input Voltage(s) Supported
- 120V AC
- UPS Input Connection Type
- 5-15P-HG
- Input Circuit Breakers
- 15A
- UPS Input Cord Length (ft.)
- 6
- Recommended Electrical Service
- 15A 120V
- Input Phase
- Single-Phase
- Input Cord Length (ft.)
- 6
Battery
- Full Load Runtime (min.)
- 10 min. (750w)
- Half Load Runtime (min.)
- 28 min. (375w)
- DC System Voltage (VDC)
- 36
- Battery Recharge Rate (Included Batteries)
- Less than 4.5 hours from 10% to 90%
- Internal UPS Replacement Battery Cartridge
- RBC53L
- Battery Access
- Battery access door
- Expandable Runtime
- No
Voltage Regulation
- Voltage Regulation Description
- Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
- Overvoltage Correction
- Input voltages between 126 and 143 are reduced by 9%
- Undervoltage Correction
- Input voltages between 96 and 106 are boosted by 10%
- Severe Undervoltage Correction
- Input voltages between 81 and 95 are boosted by 21%
User Interface, Alerts & Controls
- Switches
- 2 Switches control off/on power status and alarm-cancel/self-test operation
- Alarm Cancel Operation
- Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
- Audible Alarm
- Factory-muted audible alarm indicates power-failure, overload and low-battery conditions
- LED Indicators
- 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 940
- UPS AC Suppression Response Time
- Instantaneous
- EMI / RFI AC Noise Suppression
- Yes
- AC Suppression Joule Rating
- 940
Isolation
- Output Isolation Transformer
- Hospital grade load isolation transformer
- Leakage Current
- Less than 100 microamps
Physical
- Cooling Method
- Fan
- Installation Form Factors Supported with Optional Accessories
- Wallmount ( UPSWM - tower mounting kit)
- Primary Form Factor
- Tower
- Primary UPS Depth (mm)
- 241
- Primary UPS Height (mm)
- 318
- Primary UPS Width (mm)
- 191
- Shipping Dimensions (hwd / in.)
- 17.00 x 11.40 x 13.10
- Shipping Weight (lbs.)
- 36.54
- UPS Housing Material
- PVC
- UPS Power Module Dimensions (hwd, in.)
- 12.5 x 7.5 x 9.5
- UPS Power Module Weight (kg)
- 15.24
- UPS Power Module Weight (lbs.)
- 33.6
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 162.8
- Battery Mode BTU / Hr. (Full Load)
- 315.2
- AC Mode Efficiency Rating (100% Load)
- 94%
Communications
- Network Monitoring Port Description
- Supports detailed monitoring of UPS and site power conditions
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- USB and DB9 serial cabling included
- Communications Interface
- USB; DB9 Serial
Line / Battery Transfer
- Transfer Time
- 2-4 milliseconds
- Low Voltage Transfer to Battery Power (Setpoint)
- 81
- High Voltage Transfer to Battery Power (Setpoint)
- 143
Special Features
- Grounding Lug
- Grounding lug (equipotential)
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Hot swappable batteries
Certifications
- UPS Certifications
- Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); Tested to UL60601-1 (medical grade)
Warranty
- Product Warranty Period (Worldwide)
- 5-year limited warranty