Additional Information
- Part Number
- SM3000RMXLNTAA
- UPC
- 037332184245
Overview
- UPC Code
- 037332184245
- UPS Type
- Line-Interactive
Output
- Output Volt Amp Capacity (VA)
- 3000
- Output kVA Capacity (kVA)
- 3.00
- Output Watt Capacity (Watts)
- 2880
- Output kW Capacity (kW)
- 2.88
- Power Factor
- .96
- Nominal Voltage Details
- 120v nominal output in battery mode
- Frequency Compatibility
- 60 Hz
- Output Voltage Regulation (Line Mode)
- +6%, -14%
- Output Voltage Regulation (Battery Mode)
- +/-5%
- Load Management Receptacles
- Two switchable single outlet 5-15/20R load banks
- Output Circuit Breakers
- Two 20A output breakers protect 4 5-15/20R outlets each
- Output AC Waveform (AC Mode)
- Pure Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Nominal Output Voltage(s) Supported
- 110V; 115V; 120V
- Output Receptacles
- (8) 5-15/20R; (1) L5-30R
- Individually Controllable Load Banks
- Yes
Input
- Rated input current (Maximum Load)
- 24A
- Nominal Input Voltage(s) Supported
- 120V AC
- UPS Input Connection Type
- L5-30P
- UPS Input Cord Length (ft.)
- 10
- Recommended Electrical Service
- 30A 120V
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 3 min. (2880w)
- Half Load Runtime (min.)
- 10 min. (1440w)
- Expandable Battery Runtime
- Extended runtime supported via optional external battery packs
- External Battery Pack Compatibility
- BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
- DC System Voltage (VDC)
- 48
- Battery Recharge Rate (Included Batteries)
- Less than 5 hours from 10 to 90%
- Internal UPS Replacement Battery Cartridge
- RBC58-2U
- Battery Access
- Front panel battery access door
- Battery Replacement Description
- Hot-swappable, replaceable batteries
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
- Overvoltage Correction
- Input voltages between 127 and 145 are reduced by 12%
- Undervoltage Correction
- Input voltages between 108 and 96 are boosted by 12%
- Severe Undervoltage Correction
- Input voltages between 83 and 95 are boosted by 24%
User Interface, Alerts & Controls
- Front Panel LCD Display
- Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
- Switches
- 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset.
- Alarm Cancel Operation
- Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
- Audible Alarm
- Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
- LED Indicators
- Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). LX Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 570
- UPS Dataline Suppression
- 1 line TEL/DSL or Ethernet
- EMI / RFI AC Noise Suppression
- Yes
- AC Suppression Response Time
- Instantaneous
Physical
- Cooling Method
- Fan
- Included Mounting Accessory Description
- Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
- Installation Form Factors Supported with Included Accessories
- 4 post 19 inch rackmount
- Installation Form Factors Supported with Optional Accessories
- 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
- Minimum Required Rack Depth with External Battery Pack (cm)
- 66
- Minimum Required Rack Depth with External Battery Pack (in.)
- 26
- Minimum Required Rack Depth without External Battery Pack (cm)
- 62
- Minimum Required Rack Depth without External Battery Pack (in.)
- 24.5
- Optional Mounting Accessory Notes
- Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
- Primary Form Factor
- Rackmount
- Primary UPS Depth (mm)
- 483
- Primary UPS Height (mm)
- 89
- Primary UPS Width (mm)
- 445
- Rack Height
- 2U
- Shipping Dimensions (hwd / in.)
- 8.60 x 22.00 x 24.80
- Shipping Weight (lbs.)
- 89.00
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 3.50 x 17.50 x 19.00
- UPS Power Module Weight (kg)
- 33.02
- UPS Power Module Weight (lbs.)
- 72.8
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 409
- Battery Mode BTU / Hr. (Full Load)
- 1736
- AC Mode Efficiency Rating (100% Load)
- 96%
- Audible Noise
- 45 dBA maximum, front side 1m
Communications
- Network Monitoring Port Description
- Includes pre-installed WEBCARDLX Network Management Card interface. RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
- PowerAlert Software
- For local monitoring via the UPS’s built-in Serial or USB communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert. LX Platform Interface: PowerAlert Device Manager 15 (PADM15)
- Communications Cable
- Micro-USB, USB, and DB9 cabling included
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
- EPO Port
- RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems
- SNMP Compatibility
- SNMP V1, V2c, V3
- Network UPS Tools Compatibility
- NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
- Network Speed
- 10/100 Mbps
- Communications Interface
- DB9 Serial; EPO (emergency power off); Pre-installed network card; USB (HID enabled)
Line / Battery Transfer
- Transfer Time
- 5 milliseconds (AC to battery mode), 1 millisecond (Battery to AC mode)
- Low Voltage Transfer to Battery Power (Setpoint)
- 83
- High Voltage Transfer to Battery Power (Setpoint)
- 145
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Hot swappable batteries
- Green Energy-Saving Features
- Greater than 95% efficiency - GREEN UPS; Individually controllable load banks; Schedulable daily hours of economy mode operation
Certifications
- UPS Certifications
- Meets FCC Part 15 Category A (EMI); TAA Compliant; Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico)
- $250,000 Ultimate Lifetime Insurance