Additional Information
- Part Number
- SM2200RMDVTAA
- UPC
- 037332156310
Overview
- UPC Code
- 037332156310
- UPS Type
- Line-Interactive
Output
- Output Volt Amp Capacity (VA)
- 2200
- Output kVA Capacity (kVA)
- 2.2
- Output Watt Capacity (Watts)
- 1920
- Output kW Capacity (kW)
- 1.92
- Power Factor
- 0.87
- Frequency Compatibility
- 50 / 60 Hz
- Frequency Compatibility Details
- Automatic frequency selection
- Output Voltage Regulation (Battery Mode)
- +/- 5%
- Load Management Receptacles
- Two switchable single-outlet 5-15R load banks
- Output AC Waveform (AC Mode)
- Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Nominal Output Voltage(s) Supported
- 120V
- Output Receptacles
- (4) 5-15R; (4) 5-15/20R
- Individually Controllable Load Banks
- Yes
Input
- Rated input current (Maximum Load)
- 16A (120V), 10A (230V)
- Nominal Input Voltage(s) Supported
- 120V AC; 230V AC
- UPS Input Connection Type
- 5-20P; C20 inlet
- UPS Input Connection Description
- C20 inlet and 5 compatible plugsets (5-20P, Schuko CEE7, EU1-16P, British BS1363, Italian CEI 23-16)
- Input Circuit Breakers
- 20A
- UPS Input Cord Length (ft.)
- 6
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 12 minutes (1920 watts)
- Half Load Runtime (min.)
- 30 minutes (960 watts)
- Expandable Battery Runtime
- Extended runtime supported via optional external battery packs
- External Battery Pack Compatibility
- BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
- DC System Voltage (VDC)
- 48
- Battery Recharge Rate (Included Batteries)
- Less than 4.5 hours from 10% to 90% (internal batteries)
- Internal UPS Replacement Battery Cartridge
- RBC49-DV (quantity 2 required)
- Battery Access
- Front panel battery access door
- Battery Replacement Description
- Hot-swappable, user replaceable batteries
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- Automatic voltage regulation (AVR) maintains 120v line power output with input range of 89 to 148 or 170 to 286
- Overvoltage Correction
- Voltage reduction of 12% applies when input is between 127 and 148 (120V)
- Undervoltage Correction
- Voltage boost of 12% applies when input voltage is between 96 and 108 (120V)
User Interface, Alerts & Controls
- Switches
- 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection
- Alarm Cancel Operation
- Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
- Audible Alarm
- Audible alarm indicates power-failure, overload and low-battery conditions
- LED Indicators
- 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 340
- UPS AC Suppression Response Time
- Instantaneous
- EMI / RFI AC Noise Suppression
- Yes
Physical
- Cooling Method
- Fan
- Included Mounting Accessory Description
- Complete installation accessories available for 2 post, 4 post and tower installation
- Installation Form Factors Supported with Included Accessories
- Tower
- Installation Form Factors Supported with Optional Accessories
- 4 post rackmount full-depth ( 4POSTRAILKIT )
- Minimum Required Rack Depth with External Battery Pack (cm)
- 82
- Minimum Required Rack Depth with External Battery Pack (in.)
- 32.25
- Minimum Required Rack Depth without External Battery Pack (cm)
- 77
- Minimum Required Rack Depth without External Battery Pack (in.)
- 30.25
- Primary Form Factor
- Rackmount
- Primary UPS Depth (mm)
- 641
- Primary UPS Height (mm)
- 133
- Primary UPS Width (mm)
- 445
- Rack Height
- 3U
- Shipping Dimensions (hwd / in.)
- 12.00 x 30.00 x 30.00
- Shipping Weight (lbs.)
- 160.00
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 5.25 x 17.5 x 25.25
- UPS Power Module Weight (kg)
- 47.29
- UPS Power Module Weight (lbs.)
- 104.25
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 347
- Battery Mode BTU / Hr. (Full Load)
- 894
- AC Mode Efficiency Rating (100% Load)
- 95%
- Audible Noise
- 45 dBA maximum, front side 1m
Communications
- Network Management Cards
- SNMPWEBCARD ; WEBCARDLX
- Network Monitoring Port Description
- Supports detailed monitoring of UPS and site power conditions
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- USB and DB9 cabling included
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Network UPS Tools Compatibility
- NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
- Communications Interface
- USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Line / Battery Transfer
- Transfer Time
- 2-4 milliseconds
- Low Voltage Transfer to Battery Power (Setpoint)
- 89 (120V), 170 (230V)
- High Voltage Transfer to Battery Power (Setpoint)
- 148 (120V), 286 (230V)
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Hot swappable batteries
- Green Energy-Saving Features
- Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
Certifications
- UPS Certifications
- Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); TAA Compliant
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty