Additional Information
- Part Number
- OMNISMART350HG
- UPC
- 037332098542
Overview
- UPC Code
- 037332098542
- UPS Type
- Line-Interactive
Output
- Output Volt Amp Capacity (VA)
- 330
- Output Watt Capacity (Watts)
- 225
- Frequency Compatibility
- 60 Hz
- Output Voltage Regulation (Line Mode)
- -18%, +8%
- Output Voltage Regulation (Battery Mode)
- +/- 5%
- Output Receptacle Details
- Hospital grade output receptacles
- Output AC Waveform (AC Mode)
- Sine wave
- Output AC Waveform (Battery Mode)
- PWM sine wave
- Nominal Output Voltage(s) Supported
- 120V
- Output Receptacles
- (4) 5-15R
- Individually Controllable Load Banks
- No
Input
- Rated input current (Maximum Load)
- 2.3A
- Nominal Input Voltage(s) Supported
- 120V AC
- UPS Input Connection Type
- 5-15P-HG
- Input Circuit Breakers
- 3.5A
- UPS Input Cord Length (ft.)
- 6
- Recommended Electrical Service
- 15A 120V
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 18 min. (225w)
- Half Load Runtime (min.)
- 46 min. (115w)
- DC System Voltage (VDC)
- 12
- Battery Recharge Rate (Included Batteries)
- Less than 4.5 hours from 10% to 90%
- Internal UPS Replacement Battery Cartridge
- RBC52 (quantity 2)
- Battery Access
- Battery access door
- Battery Replacement Description
- Hot-swappable, user replaceable batteries
- Expandable Runtime
- No
Voltage Regulation
- Voltage Regulation Description
- Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89
- Undervoltage Correction
- Input voltages between 89 and 107 are boosted by 14%
User Interface, Alerts & Controls
- Switches
- 2 Switches control off/on power status and alarm-cancel/self-test operation
- Alarm Cancel Operation
- Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
- Audible Alarm
- Audible alarm indicates power-failure and low-battery conditions
- LED Indicators
- 4 LEDs indicate line power, battery power, overload and battery low/replace status
Surge / Noise Suppression
- UPS AC Suppression Response Time
- Instantaneous
- UPS Dataline Suppression
- 2 line TEL/DSL
- EMI / RFI AC Noise Suppression
- Yes
Isolation
- Output Isolation Transformer
- Hospital grade load isolation transformer
Physical
- Installation Form Factors Supported with Included Accessories
- Tower
- Installation Form Factors Supported with Optional Accessories
- Wallmount (UPSWM - tower mounting kit)
- Primary Form Factor
- Tower
- Primary UPS Depth (mm)
- 183
- Primary UPS Height (mm)
- 274
- Primary UPS Width (mm)
- 132
- Shipping Dimensions (hwd / in.)
- 14.00 x 8.00 x 10.10
- Shipping Weight (lbs.)
- 27.80
- UPS Housing Material
- PVC
- UPS Power Module Dimensions (hwd, in.)
- 10.8 x 5.2 x 7.2
- UPS Power Module Weight (kg)
- 11.34
- UPS Power Module Weight (lbs.)
- 25
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 48.8
- Battery Mode BTU / Hr. (Full Load)
- 215.8
- AC Mode Efficiency Rating (100% Load)
- 94%
Communications
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- DB9 serial cable included
- Communications Interface
- DB9 Serial
Line / Battery Transfer
- Transfer Time
- 2-4 milliseconds
- Low Voltage Transfer to Battery Power (Setpoint)
- 89
- High Voltage Transfer to Battery Power (Setpoint)
- 139
Special Features
- Grounding Lug
- Grounding lug
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Hot swappable batteries
Certifications
- UPS Certifications
- Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI); Tested to UL60601-1 (medical grade)
Warranty
- Product Warranty Period (Worldwide)