- Commercial Status
- Commercialised
- Range of product
- Harmony XB4
- Product or component type
- Complete body/contact assembly and light block
- Device short name
- ZB4
- Fixing collar material
- Zamak
- Sale per indivisible quantity
- 1
- Contacts type and composition
- 1 NC
- Contacts operation
- Slow-break
- Connections - terminals
- Screw clamp terminals: >= 1 x 0.22 mm² without cable end conforming to EN 60947-1
- Connections - terminals
- Screw clamp terminals:
- Light source
- Protected LED
- Bulb base
- Integral LED
- Light block supply
- Direct
- Light source colour
- Orange
- [Us] rated supply voltage
- 110...120 V AC, 50/60 Hz
- CAD overall width
- 1.18 in (30 mm)
- CAD overall height
- 1.85 in (47 mm)
- Terminals description ISO n°1
- (11-12)NC
- Product weight
- 0.14 lb(US) (0.064 kg)
- Contacts usage
- Standard
- Positive opening
- With positive opening conforming to EN/IEC 60947-5-1 appendix K
- Operating travel
- 0.17 in (4.3 mm) (total travel)
- Operating travel
- 0.06 in (1.5 mm) (NC changing electrical state)
- Operating force
- 2 N (NC changing electrical state)
- Mechanical durability
- 5000000 cycles
- Tightening torque
- 7.08...10.62 lbf.in (0.8...1.2 N.m) conforming to EN 60947-1
- Shape of screw head
- Slotted head compatible with flat ˜ 5.5 mm screwdriver
- Shape of screw head
- Slotted head compatible with flat ˜ 4 mm screwdriver
- Shape of screw head
- Cross head compatible with pozidriv No 1 screwdriver
- Shape of screw head
- Cross head compatible with Philips no 1 screwdriver
- Contacts material
- Silver alloy (Ag/Ni)
- Short circuit protection
- 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
- [Ith] conventional free air thermal current
- 10 A conforming to EN/IEC 60947-5-1
- [Ui] rated insulation voltage
- 600 V (degree of pollution: 3) conforming to EN 60947-1
- [Uimp] rated impulse withstand voltage
- 6 kV conforming to EN 60947-1
- [Ie] rated operational current
- 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- [Ie] rated operational current
- 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- [Ie] rated operational current
- 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- [Ie] rated operational current
- 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- [Ie] rated operational current
- 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- [Ie] rated operational current
- 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- Electrical durability
- 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- Electrical durability
- 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- Electrical durability
- 1000000 cycles, AC-15, 4 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- Electrical durability
- 1000000 cycles, AC-15, 3 A at 120 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- Electrical durability
- 1000000 cycles, AC-15, 2 A at 230 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- Signalling type
- Steady
- Current consumption
- 14 mA
- Service life
- 100000 h at rated voltage and 25°C
- Surge withstand
- 1 kV conforming to IEC 61000-4-5
- Protective treatment
- TH
- Ambient air temperature for storage
- -40...158°F (-40...70°C)
- Ambient air temperature for operation
- -13 To 158°F (-25 To 70°C)
- Class of protection against electric shock
- Class I conforming to IEC 60536
- Standards
- EN/IEC 60947-1
- Standards
- EN/IEC 60947-5-1
- Standards
- EN/IEC 60947-5-4
- Standards
- EN/IEC 60947-5-5
- Standards
- JIS C 4520
- Standards
- UL 508
- Standards
- CSA C22.2 No 14
- Product certifications
- BV
- Product certifications
- CSA
- Product certifications
- DNV
- Product certifications
- GL
- Product certifications
- LROS (Lloyds register of shipping)
- Product certifications
- RINA
- Product certifications
- UL listed
- Vibration resistance
- 5 gn (f = 2...500 Hz) conforming to IEC 60068-2-6
- Shock resistance
- 50 gn (duration = 11 ms) half sine wave acceleration conforming to IEC 60068-2-27
- Shock resistance
- 30 gn (duration = 18 ms) half sine wave acceleration conforming to IEC 60068-2-27
- Resistance to fast transients
- 2 kV conforming to IEC 61000-4-4
- Resistance to electromagnetic fields
- 9.14 V/yd (10 V/m) conforming to IEC 61000-4-3
- Resistance to electrostatic discharge
- 8 kV in free air (in insulating parts) conforming to IEC 61000-2-6
- Resistance to electrostatic discharge
- 6 kV on contact (on metal parts) conforming to IEC 61000-2-6
- Electromagnetic emission
- Class B conforming to IEC 55011