- 1 m measuring surface sound pressure level maximum [dB]
- 71.6
- Ambient temperature during operation acc. to EN 60721-3-3 Note
- Class 3K3, condensation, splashwater, and ice formation not permitted (EN 60204, Part 1)
- Ambient temperature during storage maximum [°C]
- 55
- Ambient temperature during storage minimum [°C]
- -25
- Ambient temperature during transport maximum [°C]
- 70
- Ambient temperature during transport minimum [°C]
- -40
- Ambient temperature with high overload during operation maximum [°C]
- 50
- Ambient temperature with high overload during operation minimum [°C]
- -5
- Ambient temperature with low overload during operation maximum [°C]
- 40
- Ambient temperature with low overload during operation minimum [°C]
- -5
- Ambient temperature [°F] during storage maximum [°F]
- 131
- Ambient temperature [°F] during storage maximum Note
- Class 1K3 acc. to EN 60721-3-1
- Ambient temperature [°F] during storage minimum [°F]
- -13
- Ambient temperature [°F] during transport maximum [°F]
- 158
- Ambient temperature [°F] during transport maximum Note
- Class 2K4 according to EN 60721-3-2
- Ambient temperature [°F] during transport minimum [°F]
- -40
- Ambient temperature [°F] with high overload during operation maximum [°F]
- 122
- Ambient temperature [°F] with high overload during operation minimum [°F]
- 23
- Ambient temperature [°F] with low overload during operation maximum [°F]
- 104
- Ambient temperature [°F] with low overload during operation minimum [°F]
- 23
- Apparent power output rated value [kVA]
- 5.3
- AWG number as coded connectable conductor cross section for mains supply line maximum
- 14
- AWG number as coded connectable conductor cross section for mains supply line minimum
- 16
- AWG number as coded connectable conductor cross section for motor supply line maximum
- 14
- AWG number as coded connectable conductor cross section for motor supply line minimum
- 16
- Brake version
- DC braking, compound braking, resistance braking with integrated brake chopper (for size FSGX optional)
- Certificate of suitability
- UL, cUL, CE, C-Tick (RCM), SEMI F47
- Certificate of suitability for CE marking
- Low-voltage directive 2006/95/EC
- Connectable conductor cross-section for mains supply line maximum [mm2]
- 2.5
- Connectable conductor cross-section for mains supply line minimum [mm2]
- 1.5
- Connectable conductor cross-section for motor supply line maximum [mm2]
- 2.5
- Connectable conductor cross-section for motor supply line minimum [mm2]
- 1.5
- Consumed current from supply voltage for Control Unit at DC at 24 V [A]
- 1
- Cooling air flow [m3/s]
- 0.005
- Degree of pollution
- 2 according to EN 61800-5-1
- Depth [mm]
- 165
- Design of the converter
- FSA
- Displacement factor cos phi 1
- 0.95
- Efficiency
- 0.96
- Electrical input frequency maximum [Hz]
- 63
- Electrical input frequency minimum [Hz]
- 47
- Electrical output frequency [Hz]
- 50
- Electrical output frequency for U/f control maximum [Hz]
- 550
- Electrical output frequency for U/f control minimum [Hz]
- 0
- Electrical output frequency for vector control maximum [Hz]
- 200
- Electrical output frequency for vector control minimum [Hz]
- 0
- Equipment marking acc. to DIN EN 81346-2
- Q
- Height [mm]
- 196
- IE class of the CDM
- IE2
- Input current with high overload rated value [A]
- 8.8
- Input current with low overload rated value [A]
- 10.1
- Installation altitude at height above sea level without power reduction maximum [m]
- 1000
- Installation environment regarding EMC environment A
- no
- Installation environment regarding EMC environment B
- no
- Mounting type Through-hole technology
- no
- Net weight [kg]
- 1.4
- Operating resource protection class acc. to EN 61800-5-1
- Class I (with protective bonding circuit) and Class III (PELV)
- Output current rated value maximum [A]
- 11.8
- Output current with high overload rated value [A]
- 5.9
- Output current with low overload rated value [A]
- 7.7
- Output current without overload rated value [A]
- 7.7
- Output voltage rated value [V]
- 400
- Output voltage in percent related to the input voltage maximum [%]
- 95
- Output voltage in percent related to the input voltage minimum [%]
- 0
- Phase number of the input voltage
- 3
- Phase number of the output voltage
- 3
- Power factor
- 0.85
- Power loss [W] maximum [kW]
- 0.12
- Power loss [W] of the CDM at the CDM operating point (0/100) [W]
- 85
- Power loss [W] of the CDM at the CDM operating point (0/25) [W]
- 57
- Power loss [W] of the CDM at the CDM operating point (0/50) [W]
- 65
- Power loss [W] of the CDM at the CDM operating point (50/100) [W]
- 96
- Power loss [W] of the CDM at the CDM operating point (50/25) [W]
- 59
- Power loss [W] of the CDM at the CDM operating point (50/50) [W]
- 69
- Power loss [W] of the CDM at the CDM operating point (90/100) [W]
- 113
- Power loss [W] of the CDM at the CDM operating point (90/50) [W]
- 76
- Power loss [W] of the CDM in standby mode [W]
- 12
- Product brand name
- SINAMICS
- Product component Brake chopper
- yes
- Product component Line filter
- no
- Product designation
- PM240-2
- Product function 4 quadrant operation
- no
- Product type designation
- G120
- Protection class IP
- IP20
- Protection function for converter Temperature monitoring
- yes
- Protection function for motor Temperature monitoring
- yes
- Protection function Ground fault protection
- yes
- Protection function Overload protection
- yes
- Protection function Overvoltage protection
- yes
- Protection function parameter lock
- yes
- Protection function Short-circuit protection
- yes
- Protection function Stall protection
- yes
- Protection function undervoltage protection
- yes
- Protection function with blocked rotor
- yes
- Pulse frequency rated value [kHz]
- 4
- Ratio of converter losses/reference converter losses at the CDM operating point (90/100)
- 68.6
- Relative humidity without condensation during operation maximum [%]
- 95
- Relative humidity without condensation during operation maximum Note
- RH, condensation not permitted
- Relative negative tolerance for line voltage [%]
- -10
- Relative negative tolerance of line frequency [%]
- 5
- Relative positive tolerance for line voltage [%]
- 10
- Relative positive tolerance of line frequency [%]
- 5
- Relative power loss [W] of the CDM at the CDM operating point (0/100) [%]
- 1.6
- Relative power loss [W] of the CDM at the CDM operating point (0/25) [%]
- 1.06
- Relative power loss [W] of the CDM at the CDM operating point (0/50) [%]
- 1.21
- Relative power loss [W] of the CDM at the CDM operating point (50/100) [%]
- 1.8
- Relative power loss [W] of the CDM at the CDM operating point (50/25) [%]
- 1.1
- Relative power loss [W] of the CDM at the CDM operating point (50/50) [%]
- 1.3
- Relative power loss [W] of the CDM at the CDM operating point (90/100) [%]
- 2.11
- Relative power loss [W] of the CDM at the CDM operating point (90/50) [%]
- 1.42
- Resistance to biologically active substances during operation
- Class 3B1 according to EN 60721-3-3
- Resistance to biologically active substances during storage
- Class 1B1 according to EN 60721-3-1
- Resistance to biologically active substances during transport
- Class 2B1 to EN 60721€‘3€‘2
- Resistance to chemically active substances during operation
- Class 3C2 according to EN 60721-3-3
- Resistance to chemically active substances during storage
- Class 1C2 according to EN 60721-3-1
- Resistance to chemically active substances during transport
- Class 2C2 according to EN 60721-3-3
- Shock acceleration during operation acc. to EN 60068-2-27 [m/s2]
- 147
- Shock acceleration during operation Note
- (15 × g)/11 ms
- Shock acceleration during transport acc. to EN 60721-3-2 Note
- Class 2M3
- Short-time withstand current (SCCR) of the entire control cabinet acc. to UL 508A [kA]
- 65
- Standard for EMC acc. to EN 61800-3
- The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter.
- Supplied active power at rated value of output voltage with high overload [kW]
- 2.2
- Supplied active power at rated value of output voltage with low overload [kW]
- 3
- Supplied active power [hp] at rated value of output voltage with high overload [hp]
- 3
- Supplied active power [hp] at rated value of output voltage with low overload [hp]
- 4
- Supply requirements for short circuit voltage
- u K < 1 % line reactor recommended
- Supply voltage maximum [V]
- 480
- Supply voltage minimum [V]
- 380
- Touch protection acc. to EN 61800-5-1
- Assuming use as prescribed
- Type of converter
- U converter
- Type of cooling
- Internal air cooling
- Type of cooling Note
- Power units with intensified air cooling thanks to integrated fan
- Type of duty cycle duration with high overload
- 1.5 × output current rating (i.e., 150 % overload) for 57 s with a cycle time of 300 s 2 × output current rating (i.e., 200 % overload) for 3 s with a cycle time of 300 s
- Type of duty cycle duration with low overload
- 1.1 x rated output current (i.e. 110 % overload) for 57 s with a cycle time of 300 s 1.5 × rated output current (i.e. 150 % overload) for 3 s with a cycle time of 300 s
- Type of electrical connection for mains supply line
- Plug-in screw terminals
- Type of electrical connection for PE conductor
- Plug-in screw terminals
- Type of electrical connection of the motor
- Plug-in screw terminals
- Type of voltage of the input voltage
- AC
- Type of voltage of the output voltage
- AC
- Vibration frequency during transport acc. to EN 60721-3-2 Note
- Class 2M3
- Vibration frequency with constant acceleration during operation acc. to EN 60068-2-6 maximum [Hz]
- 200
- Vibration frequency with constant acceleration during operation acc. to EN 60068-2-6 maximum Note
- constant acceleration = 9.81 m/s2 (1 × g)
- Vibration frequency with constant acceleration during operation acc. to EN 60068-2-6 minimum [Hz]
- 58
- Vibration frequency with constant deflection during operation acc. to EN 60068-2-6 maximum [Hz]
- 58
- Vibration frequency with constant deflection during operation acc. to EN 60068-2-6 maximum Note
- constant deflection 0.075 mm
- Vibration frequency with constant deflection during operation acc. to EN 60068-2-6 minimum [Hz]
- 10
- Width [mm]
- 73
- Wire length for motor shielded maximum [m]
- 50
- Wire length for motor unshielded maximum [m]
- 100