Additional Information
- Part Number
- XPSUDN13AC
- UNSPSC
- 32151705
- Tariff Code
- 8536410060
- Country of Origin
- ID
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1811003EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1811003EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- TœV || cULus
- Ambient Air Temperature For Operation
- -25-50°C at 24 V AC || -25-55°C at 24 V DC
- Ip Degree Of Protection
- IP20 terminals)IEC 60947-1 || IP40 housing)IEC 60947-1 || IP54 mounting area)IEC 60947-1
- Standards
- IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
- Ambient Air Temperature For Storage
- -25-85°C
- Relative Humidity
- 5-95 % non-condensing
Specifications
- [Us] Rated Supply Voltage
- 24 V AC - 15...10 % || 24 V DC - 20...20 %
- Range Of Product
- Harmony Safety Automation
- Product Or Component Type
- safety module
- Safety Module Name
- XPSUDN
- Connections - Terminals
- removable spring terminal block, 0.2...2.5 mm² solid or flexible || removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
- Safety Module Application
- monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring
- Safety Reliability Data
- MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 0.88E-09 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 0.88E-09 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 0.88E-09 IEC 61508-1 || SFF > 99% IEC 61508-1 || type = B IEC 61508-1
- Electrical Circuit Type
- NC pair || PNP pair || antivalent pair || OSSD pair
- Function Of Module
- emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || proximity sensor monitoring
- Safety Level
- can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508
Complementary
- Number Of Outputs
- 7 on/off configurable pulsed output
- Height
- 100 mm
- Mounting Support
- 35 mm symmetrical DIN rail
- Minimum Output Voltage
- 12 V relay output
- Minimum Output Current
- 10 mA relay output
- [Ith] Conventional Free Air Thermal Current
- 16 A
- Input/Output Type
- semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
- Associated Fuse Rating
- 10 A gG NO relay output circuit IEC 60947-1 || 4 A gG NC relay output circuit IEC 60947-1
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV II IEC 60947-1
- Net Weight
- 0.350 kg
- Type Of Start
- automatic/manual/monitored
- Number Of Inputs
- 6 safety input 24 V DC 5
- Input Compatibility
- normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
- Power Consumption In Va
- 10.5 VA 24 V AC 50/60 Hz
- [Ie] Rated Operational Current
- 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 3 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact
- Auxiliary Contact Composition
- 3 NO + 1 NC
- [Ui] Rated Insulation Voltage
- 250 V 2)IEC 60947-1
- Power Consumption In W
- 4.5 W 24 V DC
- Maximum Line Resistance
- 500 Ohm
- Local Signalling
- for power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S13 LED (yellow) || for safety input S22 LED (yellow) || for safety input S23 LED (yellow) || for safety input S32 LED (yellow) || for safety input S33 LED (yellow) || for safety input S42 LED (yellow) || for safety input S43 LED (yellow) || for safety input S52 LED (yellow) || for safety input S53 LED (yellow) || for safety input S62 LED (yellow) || for safety input S73 LED (yellow)
- Input Protection Type
- internal, electronic
- Width
- 45 mm
- Depth
- 120 mm
- Synchronisation Time Between Inputs
- 0.5 s || 2 s || 2.2 s || 4 s
- Maximum Response Time On Input Open
- 20 ms