Additional Information Part Number XPSBAC14AP UNSPSC 32151802 Tariff Code 8536410050 Complementary Terminal Identifier power supply Number Of Outputs 0 Height 100 mm Mounting Support 35 mm symmetrical DIN rail Minimum Output Voltage 5 V relay output Response Time 150 ms at 24 V AC || 80 ms at 24 V DC Minimum Output Current 10 mA relay output [Ith] Conventional...

Additional Information

Part Number
XPSBAC14AP
UNSPSC
32151802
Tariff Code
8536410050

Complementary

Terminal Identifier
power supply
Number Of Outputs
0
Height
100 mm
Mounting Support
35 mm symmetrical DIN rail
Minimum Output Voltage
5 V relay output
Response Time
150 ms at 24 V AC || 80 ms at 24 V DC
Minimum Output Current
10 mA relay output
[Ith] Conventional Free Air Thermal Current
6 A
Associated Fuse Rating
10 A gG NO relay output circuit IEC 60947-1
Local Signalling
LED green power power ON || LED red error error || LED yellow state status || LED yellow start1 start input || LED yellow start2 start input
[Uimp] Rated Impulse Withstand Voltage
4 kV II IEC 60947-1
Net Weight
0.200 kg
Type Of Start
automatic/manual/monitored
Number Of Inputs
0
Input Compatibility
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850
Power Consumption In Va
3.5 VA 24 V AC 50/60 Hz
[Ie] Rated Operational Current
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 3 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact
Auxiliary Contact Composition
4 NO + 1 NC
[Ui] Rated Insulation Voltage
300 V 2)IEC 60947-1
Power Consumption In W
1.5 W 24 V DC
Input Protection Type
internal, electronic
Width
22.5 mm
Depth
120 mm
Synchronisation Time Between Inputs
unlimited

Environment

Product Certifications
TœV || cULus
Ambient Air Temperature For Operation
-25-55°C
Ip Degree Of Protection
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
Standards
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
Relative Humidity
5-95 % non-condensing

Specifications

[Us] Rated Supply Voltage
24 V AC - 15...10 % || 24 V DC - 20...20 %
Range Of Product
Harmony Safety Automation
Product Or Component Type
safety module
Safety Module Name
XPSBAC
Connections - Terminals
removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Safety Module Application
for emergency stop and protective guard applications
Safety Reliability Data
MTTFd > 30 years for normally open relay contact ISO 13849-1 || Dcavg >= 99 % for normally open relay contact ISO 13849-1 || PFHd = 0.95E-09 for normally open relay contact ISO 13849-1 || HFT = 1 for normally open relay contact IEC 62061 || PFHd = 0.95E-09 for normally open relay contact IEC 62061 || SFF > 99% for normally open relay contact IEC 62061 || HFT = 1 for normally open relay contact IEC 61508-1 || PFHd = 0.95E-09 for normally open relay contact IEC 61508-1 || SFF > 99% for normally open relay contact IEC 61508-1 || type = B for normally open relay contact IEC 61508-1 || MTTFd > 30 years for normally closed relay contact ISO 13849-1 || DC > 60 % for normally closed relay contact ISO 13849-1 || PFHd = 0.95E-09 for normally closed relay contact ISO 13849-1 || HFT=0 for normally closed relay contact IEC 62061 || PFHd = 0.95E-09 for normally closed relay contact IEC 62061 || SFF > 60% for normally closed relay contact IEC 62061 || HFT=0 for normally closed relay contact IEC 61508-1 || PFHd = 0.95E-09 for normally closed relay contact IEC 61508-1 || SFF > 60% for normally closed relay contact IEC 61508-1 || type = B for normally closed relay contact IEC 61508-1
Electrical Circuit Type
NC pair
Function Of Module
emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches
Safety Level
can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1811003EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1811003EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products