Additional Information Part Number XPSAC5121P UNSPSC 32151802 Tariff Code 8536410060 Country of Origin ID Specifications [Us] Rated Supply Voltage 24 V AC - 20...10 % || 24 V DC - 20...20 % Range Of Product Preventa Safety automation Product Or Component Type Preventa safety module Safety Module Name XPSAC Type Of Start unmonitored Output Type relay instantaneous opening, 3 NO,...

Additional Information

Part Number
XPSAC5121P
UNSPSC
32151802
Tariff Code
8536410060
Country of Origin
ID

Specifications

[Us] Rated Supply Voltage
24 V AC - 20...10 % || 24 V DC - 20...20 %
Range Of Product
Preventa Safety automation
Product Or Component Type
Preventa safety module
Safety Module Name
XPSAC
Type Of Start
unmonitored
Output Type
relay instantaneous opening, 3 NO, volt-free
Connections - Terminals
captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Number Of Additional Circuits
1 solid state output
Safety Module Application
for emergency stop and switch monitoring
Safety Reliability Data
MTTFd = 210.4 years EN/ISO 13849-1 || DC > 99 % EN/ISO 13849-1 || PFHd = 3.56E-9 1/h EN/IEC 62061
Function Of Module
switch monitoring || emergency stop
Safety Level
can reach PL e/category 4 EN/ISO 13849-1 || can reach SILCL 3 EN/IEC 62061

Contractual warranty

Warranty
18 months

Complementary

[Uc] Control Circuit Voltage
24 V
Mounting Support
35 mm symmetrical DIN rail
Output Thermal Current
6 A per relay relay output
Minimum Output Voltage
16 V relay output
Current Consumption
40 mA 24 V DC on power supply || 90 mA 24 V AC on power supply
Minimum Output Current
10 mA relay output
[Ith] Conventional Free Air Thermal Current
10.5 A
Associated Fuse Rating
4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 || 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
[Uimp] Rated Impulse Withstand Voltage
4 kV III IEC 60947-5-1 || 4 kV III DIN VDE 0110 part 1
Net Weight
0.16 kg
[Ui] Rated Insulation Voltage
300 V 2)IEC 60947-5-1 || 300 V 2)DIN VDE 0110 part 1
Local Signalling
2 LEDs
Breaking Capacity
1.5 A 24 V DC-13)50 ms relay output
Maximum Power Consumption In Va
2.5 VA AC
Maximum Power Consumption In W
1.2 W DC
Supply Frequency
50/60 Hz
Maximum Response Time On Input Open
100 ms
Breaking Capacity
180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1406024EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1406024EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || CSA || TœV
Ambient Air Temperature For Operation
-10-55°C
Standards
EN/ISO 13850 || EN/IEC 60947-5-1 || EN 60204-1 || EN 1088/ISO 14119
Ip Degree Of Protection
IP20 terminals)EN/IEC 60529 || IP40 enclosure)EN/IEC 60529
Ambient Air Temperature For Storage
-25-85°C

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products