SCHNEIDER-ELECTRIC RE22R1QCMU-Dropship Automation

SCHNEIDER-ELECTRIC RE22R1QCMU

SKU: DA-3185
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number RE22R1QCMU UNSPSC 39122329 Tariff Code 8536490080 Country of Origin ID Offer Sustainability Rohs Exemption Information Yes Mercury Free Yes Environmental Disclosure ENVPEP1401008EN Sustainable Offer Status Green Premium product Reach Regulation Reference contains Substances of Very High Concern above the threshold California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds,...

Additional Information

Part Number
RE22R1QCMU
UNSPSC
39122329
Tariff Code
8536490080
Country of Origin
ID

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1401008EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Circularity Profile
ENVEOLI1401008EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Power Consumption In W
0.6 W 24 V DC
Safety Reliability Data
MTTFd = 285.3 years || B10d = 270000
Contacts Type And Composition
1 C/O timed contact, cadmium free
Setting Accuracy Of Time Delay
+/- 10 % of full scale 25°C IEC 61812-1
Creepage Distance
4 kV/3 IEC 60664-1
Maximum Delay Response
100 ms
Control Type
rotary knob || diagnostic button
Insulation Resistance
100 MOhm 500 V DC IEC 60664-1
Immunity To Microbreaks
10 ms
Power Consumption In Va
35-35 VA 240 V AC
Switching Capacity In Va
2000 VA
Maximum Switching Current
8 A
Voltage Range
0.85...1.1 Us
Net Weight
0.08 kg
Mounting Position
any position
Voltage Drift
+/- 0.2 %/V
Reset Time
120 ms on de-energisation
Maximum Switching Voltage
250 V AC
Connections - Terminals
screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Us] Rated Supply Voltage
24 V DC || 24...240 V AC 50/60 Hz
Temperature Drift
+/- 0.05 %/°C
Time Delay Range
10...100 s || 3...30 s || 0.1...1 s || 0.3...3 s || 0.05...0.5 s || 1...10 s || 30...300 s
Minimum Switching Current
10 mA 5 V DC
Overvoltage Category
III IEC 60664-1
Input Voltage
<= 2.4 V
Mounting Support
35 mm DIN rail conforming to IEC 60715
Electrical Durability
100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1
Mechanical Durability
10000000 cycles
Housing Material
self-extinguishing
Status Led
Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised
[Uimp] Rated Impulse Withstand Voltage
5 kV 1.2-50 µs IEC 60664-1
Width
22.5 mm
Time Delay Type
star-delta
Tightening Torque
0.6-1 N.m IEC 60947-1
Supply Frequency
50...60 Hz +/- 5 %
Repeat Accuracy
+/- 0.5 % IEC 61812-1

Environment

Product Certifications
GL || CE || CCC || EAC || UL || CSA || RCM
Ambient Air Temperature For Operation
-20-60°C
Standards
UL 508 || IEC 61812-1
Electromagnetic Compatibility
fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 || surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 || surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 || electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 || electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 || conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 || fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 || immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 || immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Dielectric Strength
2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
Shock Resistance
15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27
Vibration Resistance
20 m/s² 10-150 Hz)IEC 60068-2-6
Pollution Degree
3 IEC 60664-1
Directives
2004/108/EC - electromagnetic compatibility || 2006/95/EC - low voltage directive
Ambient Air Temperature For Storage
-40-70°C
Relative Humidity
95-95 % 25-55°C
Ip Degree Of Protection
housing IP40 IEC 60529 || front face IP50 IEC 60529 || terminals IP20 IEC 60529

Specifications

Discrete Output Type
relay
Range Of Product
Harmony Timer Relays
Product Or Component Type
single function relay
Nominal Output Current
8 A
Device Short Name
RE22

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products