SCHNEIDER-ELECTRIC METSEION7410-Dropship Automation

SCHNEIDER-ELECTRIC METSEION7410

SKU: DA-601867
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number METSEION7410 UNSPSC 83101808 Tariff Code 9030840000 Complementary Communication Network Type IPv6 (internet protocol) Network Frequency 50 Hz || 60 Hz Communication Port Support ETHERNET || screw terminal block RS485 || optical probe fiber optic || mini B USB USB Power Quality Analysis EN 50160 2010 compliance report || IEEE 519 2014 compliance report || IEC 61000-4-30...

Additional Information

Part Number
METSEION7410
UNSPSC
83101808
Tariff Code
9030840000

Complementary

Communication Network Type
IPv6 (internet protocol)
Network Frequency
50 Hz || 60 Hz
Communication Port Support
ETHERNET || screw terminal block RS485 || optical probe fiber optic || mini B USB USB
Power Quality Analysis
EN 50160 2010 compliance report || IEEE 519 2014 compliance report || IEC 61000-4-30 class S power quality measurement || up to the 63rd harmonic || harmonic distortion || waveform capture || voltage sag and swell detection || programmablity (logic and math functions) || IEC 62586 power quality monitoring || IEC 61000-4-15 disturbance direction detection || rapid voltage change
Height
112 mm
Measurement Voltage
57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases
Sampling Rate
256 samples/cycle
Standards
IEC 61557-12 || IEC 61326-1 || IEC 62052-11 || IEC 62053-24 || IEC 62053-22 || IEEE 1588 || IEC 62586
Memory Capacity
512 MB
Number Of Outputs
1 pulse
Product Certifications
CE || cULus || N998
Type Of Measurement
current || voltage || frequency || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms || active and reactive energy || apparent energy
Communication Port Protocol
Modbus RTU 115 kbauds - 2-wire || ION 115 kbauds - 2-wire || DNP3 || IEC 61850 || Modbus TCP/IP || Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s || RSTP 801.1d 2004 || Ansi C12.19 || DLMS
Power Consumption In W
17 W
Frequency Measurement Range
42-69 Hz
Communication Service
SNMP || SMTP e-mail notification || RSTP support || DHCP || NTP time synchronization || PTP time synchronization
Display Resolution
320 x 240 pixels QVGA
Number Of Inputs
3 digital 30 V AC || 3 digital 60 V DC
Net Weight
706 g
Type Of Installation
indoor installation
Depth
78.5 mm
Measurement Current
50-10000 mA
Information Displayed
voltage || current || frequency || power || energy consumption || harmonic distortion
[Us] Rated Supply Voltage
20...60 V DC +/- 10 %
Mounting Mode
flush-mounted
Measurement Accuracy
current +/- 0.1 % || voltage +/- 0.1 % || active energy +/- 0.2 %
Mounting Support
framework
Poles Description
1P + N || 3P + N || 3P
Data Recording
data logs || sag and swell logs || waveform logs || trending/forecasting || sequence of event recording || GPS synchronisation || harmonics logs || time stamping || alarm logs || event logs || min/max of instantaneous values || 50 data recorders
Line Rated Current
10 A || 1 A || 5 A
Cybersecurity
enable/disable communication ports || port hardening || Syslog protocol support || password protection || robust security logs
Isolation Voltage
III400-690 V conforming to IEC 61010-1:ed. 3 || III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
Analogue Input Type
voltage (impedance 5 MOhm) || current (impedance 0.3 mOhm)
Web Services
customizable home page || file upload/download via FTP || file upload/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server
Width
98 mm
Display Type
colour TFT LCD
Device Application
data aggregation || revenue billing || WAGES metering || power monitoring
Accuracy Class
class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 current IEC 61557-12 || class 0.2 frequency IEC 61557-12 || class 0.2 active energy IEC 61557-12
Installation Category
III

Offer Sustainability

Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP1512006EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1512006EN
Eu Rohs Directive
Compliant with Exemptions

Environment

Ambient Air Temperature For Operation
-25-70°C
Electromagnetic Compatibility
electrostatic discharge conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test conforming to IEC 61000-4-4 || surge immunity test conforming to IEC 61000-4-5 || conducted RF disturbances conforming to IEC 61000-4-6 || magnetic field at power frequency conforming to IEC 61000-4-8 || voltage dips and interruptions immunity test conforming to IEC 61000-4-11 || immunity to impulse waves conforming to IEC 61000-4-12 || conducted and radiated emissions conforming to EN 55022 || conducted and radiated emissions conforming to EN 55011 || conducted and radiated emissions conforming to FCC part 15 || conducted and radiated emissions conforming to ICES-003 || conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579 || surge withstand conforming to IEEE C37.90.1
Ambient Air Temperature For Storage
-40-85°C
Relative Humidity
5-95 %
Ip Degree Of Protection
front IP54 IEC 60529 || body IP30 IEC 60529
Operating Altitude
9842.52 ft (3000 m)

Specifications

Product Or Component Type
power meter
Product Name
PowerLogic ION7400
Range
PowerLogic
Device Short Name
ION7410

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products