Additional Information Part Number LR9F5563 UNSPSC 39122330 Country of Origin FR Specifications Network Type AC Thermal Protection Adjustment Range 48-80 A Relay Application motor protection Product Or Component Type electronic thermal overload relay Product Name TeSys LRF Thermal Overload Class class 20 IEC 60947-4 Range TeSys Product Compatibility LC1F115...LC1F185 Device Short Name LR9F Contractual warranty Warranty 18 months Complementary Network...

Additional Information

Part Number
LR9F5563
UNSPSC
39122330
Country of Origin
FR

Specifications

Network Type
AC
Thermal Protection Adjustment Range
48-80 A
Relay Application
motor protection
Product Or Component Type
electronic thermal overload relay
Product Name
TeSys LRF
Thermal Overload Class
class 20 IEC 60947-4
Range
TeSys
Product Compatibility
LC1F115...LC1F185
Device Short Name
LR9F

Contractual warranty

Warranty
18 months

Complementary

Network Frequency
50/60 Hz
Current Consumption
<= 5 mA no-load
Height
96 mm
[Ith] Conventional Free Air Thermal Current
5 A control circuit
Tightening Torque
control circuit 1.2 N.m screw clamp terminals || power circuit 18 N.m screw clamp terminals
Reset
manual reset on front relay
Phase Failure Sensitivity
tripping in 4 s +/- 20 % IEC 60947-4-1
[Ue] Rated Operational Voltage
1000 V AC 50/60 Hz power circuit VDE 0110 group C
Switching Capacity In Ma
0...150 mA
Net Weight
0.9 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947-1
Maximum Voltage Drop
<2.5 V closed state
Connections - Terminals
control circuit screw clamp terminals 1 0.75-2.5 mm² flexible - with cable end || control circuit screw clamp terminals 1 0.75-2.5 mm² solid || control circuit screw clamp terminals 1 0.75-4 mm² flexible - without cable end || control circuit screw clamp terminals 2 1-1.5 mm² flexible - with cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible - without cable end || control circuit screw clamp terminals 2 1-1 mm² solid || power circuit lugs-ring terminals M8
[Ui] Rated Insulation Voltage
power circuit 1000 V AC IEC 60947-4
Contacts Type And Composition
1 NO + 1 NC
Surge Withstand
4 kV IEC 61000-4-5
Tripping Threshold
1.12 +/- 0.06 In tripping IEC 60947-4-1
Mounting Support
direct on contactor || plate
Control Type
dial White full-load current adjustment || test button Red || push-button Red reset || push-button stop
Local Signalling
trip indicator
Width
115 mm
Depth
123.5 mm
Temperature Compensation
-20-70°C

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP080207EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI100406
Eu Rohs Directive
Compliant

Environment

Product Certifications
CSA || UL || UKCA
Mechanical Robustness
shocks13 Gn for 11 ms IEC 60068-2-7 || vibrations 5...300 Hz2 GN IEC 60068-2-6
Standards
IEC 60255-17 || VDE 0660 || IEC 60255-8 || IEC 60947-4-1 || EN 60947-4-1
Ambient Air Temperature For Operation
-20-55°C IEC 60255-8
Electromagnetic Compatibility
resistance to electrostatic discharge 6 kV in indirect mode IEC 61000-4-2 || resistance to electrostatic discharge 8 kV in air IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/m IEC 61000-4-3 || fast transients immunity test 2 kV IEC 61000-4-4
Dielectric Strength
6 kV 50 Hz IEC 255-5
Ip Degree Of Protection
IP20 conforming to IEC 60529 || IP20 conforming to VDE 0106
Ambient Air Temperature For Storage
-40-85°C
Protective Treatment
TH
Operating Altitude
<= 6561.68 ft (2000 m) without derating
Fire Resistance
850°C IEC 60695-2-1

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products