SCHNEIDER-ELECTRIC LR9D08-Dropship Automation

SCHNEIDER-ELECTRIC LR9D08

SKU: DA-383215
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number LR9D08 UNSPSC 39122330 Tariff Code 8536490075 Country of Origin CN Specifications Thermal Protection Adjustment Range 1.6-8 A Power Consumption In W 300 mW Relay Application motor protection Product Or Component Type electronic thermal overload relay Product Name TeSys LRD Thermal Overload Class class 5¦30 Range TeSys Mounting Support under contactor || plate, with specific accessories ||...

Additional Information

Part Number
LR9D08
UNSPSC
39122330
Tariff Code
8536490075
Country of Origin
CN

Specifications

Thermal Protection Adjustment Range
1.6-8 A
Power Consumption In W
300 mW
Relay Application
motor protection
Product Or Component Type
electronic thermal overload relay
Product Name
TeSys LRD
Thermal Overload Class
class 5¦30
Range
TeSys
Mounting Support
under contactor || plate, with specific accessories || rail, with specific accessories
Product Compatibility
LC1D12 || LC1D32 || LC1D38 || LC1D09 || LC1D25 || LC1D18
Device Short Name
LR9D

Environment

Product Certifications
IECEE CB Scheme || UL || CSA || CCC
Mechanical Robustness
vibrations 10...150 Hz6 Gn IEC 60068-2-6 || shocks 11 ms15 gn IEC 60068-2-7
Standards
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 || GB/T 14048.5
Ambient Air Temperature For Operation
-25-70°C IEC 60255-8
Dielectric Strength
6 kV 50 Hz IEC 60255-5
Ambient Air Temperature For Storage
-55-80°C
Ip Degree Of Protection
IP20 front face IEC 60529
Operating Altitude
6561.68 ft (2000 m) without derating

Complementary

Time Range
1.5...4 min - automatic reset time
Height
72.5 mm
[Ith] Conventional Free Air Thermal Current
5 A signalling circuit
Tightening Torque
control circuit 0.8 N.m screw clamp terminals || power circuit 3.1 N.m screw clamp terminals
Phase Failure Sensitivity
phase difference > 40% 3-3 s IEC 60947-4-1
[Ue] Rated Operational Voltage
690 V power circuit || 660 V signalling circuit
Electromagnetic Compatibility
surge withstand 2 kV common mode IEC 61000-4-5 || resistance to electrostatic discharge 8 kV IEC 61000-4-2 || immunity to radiated radio-electrical interference 10 V/m IEC 61000-4-3 || immunity to fast transients 2 kV IEC 61000-4-4
Associated Fuse Rating
5 A gG for signalling circuit || 5 A BS for signalling circuit
Net Weight
0.18 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV
Connections - Terminals
control circuit screw clamp terminals 1 2.5-2.5 mm² solid or flexible - without cable end || power circuit screw clamp terminals 1 16-16 mm² solid or flexible - without cable end
[Ui] Rated Insulation Voltage
power circuit 1000 V || signalling circuit 690 V
Tripping Threshold
1.25 In IEC 60947-4-1
Control Type
Red push-button stop and manual reset || White 2 microswitches adjustable trip class || Red knob automatic reset || White dial full-load current adjustment
Width
45 mm
Depth
79.9 mm

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1502001EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI1502001EN
Eu Rohs Directive
Compliant with Exemptions

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products