SCHNEIDER-ELECTRIC LC2F150-Dropship Automation

SCHNEIDER-ELECTRIC LC2F150

SKU: DA-563216
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number LC2F150 UNSPSC 39121529 Tariff Code 8536490065 Country of Origin CZ Specifications Product Certifications CB || RMRoS || DNV || ABS || UL || CCC || CSA || LROS (Lloyds register of shipping) || RINA || UKCA Interlocking Type mechanical [Ue] Rated Operational Voltage <= 1000 V AC 50/60 Hz || <= 460 V DC Power Dissipation...

Additional Information

Part Number
LC2F150
UNSPSC
39121529
Tariff Code
8536490065
Country of Origin
CZ

Specifications

Product Certifications
CB || RMRoS || DNV || ABS || UL || CCC || CSA || LROS (Lloyds register of shipping) || RINA || UKCA
Interlocking Type
mechanical
[Ue] Rated Operational Voltage
<= 1000 V AC 50/60 Hz || <= 460 V DC
Power Dissipation Per Pole
8 W AC-3
Average Impedance
0.35 mOhm - Ith 250 A 50 Hz
Auxiliary Contact Composition
1 NO
[Ith] Conventional Free Air Thermal Current
250 A 40°C
Standards
EN 60947-4-1 || JIS C8201-4-1 || EN 60947-1 || IEC 60947-4-1 || IEC 60947-1
Mounting Support
plate
Contactor Application
resistive load || motor control
Rated Breaking Capacity
1200 A IEC 60947-4-1
Product Or Component Type
reversing contactor
Irms Rated Making Capacity
1500 A AC IEC 60947-4-1
Product Name
TeSys F
Associated Fuse Rating
160 A aM <= 440 V || 250 A gG <= 440 V
[Uimp] Rated Impulse Withstand Voltage
8 kV
Connections - Terminals
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit connector 1 120-120 mm² || power circuit lugs-ring terminals 1 120-120 mm² || power circuit bar 2 25 x 3 mm
Range
TeSys
Pole Contact Composition
3 NO
Device Presentation
preassembled with reversing power busbar
Utilisation Category
AC-3 || AC-1
[Ie] Rated Operational Current
250 A 40°C) <= 440 V AC AC-1 || 150 A 55°C) <= 440 V AC AC-3
Tightening Torque
control circuit 1.2 N.m || power circuit 18 N.m
Poles Description
3P
Overvoltage Category
III
Motor Power Kw
65 kW 1000 V AC 50/60 Hz || 75 kW 380...400 V AC 50/60 Hz || 80 kW 415 V AC 50/60 Hz || 80 kW 440 V AC 50/60 Hz || 90 kW 500 V AC 50/60 Hz || 40 kW 220...240 V AC 50/60 Hz || 100 kW 660...690 V AC 50/60 Hz
[Ui] Rated Insulation Voltage
1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
Device Short Name
LC2F
[Icw] Rated Short-Time Withstand Current
1200 A 40°C - 10 s || 700 A 40°C - 30 s || 600 A 40°C - 1 min || 450 A 40°C - 3 min || 350 A 40°C - 10 min

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111201EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI111214EN_V1
Eu Rohs Directive
Compliant

Environment

Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed6 Gn, 5...300 Hz || shocks contactor open9 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Ambient Air Temperature For Operation
-5-55°C
Height
170 mm
Net Weight
7.56 kg
Ambient Air Temperature For Storage
-60-80°C
Protective Treatment
TH
Ip Degree Of Protection
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Operating Altitude
9842.52 ft (3000 m) without derating
Fire Resistance
850°C IEC 60695-2-1
Width
345 mm
Depth
171 mm
Permissible Ambient Air Temperature Around The Device
-40-70°C

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products