SCHNEIDER-ELECTRIC BMXDRC0805-Dropship Automation

SCHNEIDER-ELECTRIC BMXDRC0805

SKU: DA-351329
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number BMXDRC0805 UNSPSC 32151703 Tariff Code 8537109170 Country of Origin FR Complementary Mtbf Reliability 2650000 H Network Frequency 50/60 Hz Voltage Range 5...150 V || 19...264 V Minimum Switching Current 10 mA 5 V DC [Ith] Conventional Free Air Thermal Current 4 A 40°C || 3 A 50°C || 2 A 60°C Status Led 1 LED (Green)...

Additional Information

Part Number
BMXDRC0805
UNSPSC
32151703
Tariff Code
8537109170
Country of Origin
FR

Complementary

Mtbf Reliability
2650000 H
Network Frequency
50/60 Hz
Voltage Range
5...150 V || 19...264 V
Minimum Switching Current
10 mA 5 V DC
[Ith] Conventional Free Air Thermal Current
4 A 40°C || 3 A 50°C || 2 A 60°C
Status Led
1 LED (Green) RUN || 1 LED per channel (Green) channel diagnostic || 1 LED (Red) ERR || 1 LED (Red) I/O
Insulation Resistance
> 10 MOhm 500 V DC
Network Frequency Limits
47-63 Hz
Protection Type
external short-circuit protection || external overload protection || external overvoltage protection, inductive AC || external overvoltage protection, inductive DC
Power Dissipation In W
3.6 W
Net Weight
0.189 kg
Electrical Connection
40 ways terminal block
Electrical Durability
AC-12 200000 cycles 48 VA 24 V 0-60°C || AC-12 300000 cycles 48 VA 48 V 0-60°C || AC-12 150000 cycles 96 VA 48 V 0-60°C || AC-12 300000 cycles 110 VA 100...120 V 0-60°C || AC-12 150000 cycles 220 VA 100...120 V 0-60°C || AC-12 300000 cycles 220 VA 200...250 V 0-60°C || AC-12 150000 cycles 500 VA 200...250 V 0-60°C || AC-15 700000 cycles 10 VA 24 V 0-60°C 0.4 ) || AC-15 500000 cycles 24 VA 24 V 0-60°C 0.4 ) || AC-15 200000 cycles 48 VA 24 V 0-60°C 0.4 ) || AC-15 700000 cycles 10 VA 48 V 0-60°C 0.4 ) || AC-15 500000 cycles 24 VA 48 V 0-60°C 0.4 ) || AC-15 300000 cycles 48 VA 48 V 0-60°C 0.4 ) || AC-15 100000 cycles 96 VA 48 V 0-60°C 0.4 ) || AC-15 1000000 cycles 10 VA 100...120 V 0-60°C 0.4 ) || AC-15 300000 cycles 50 VA 100...120 V 0-60°C 0.4 ) || AC-15 200000 cycles 110 VA 100...120 V 0-60°C 0.4 ) || AC-15 70000 cycles 220 VA 100...120 V 0-60°C 0.4 ) || AC-15 1000000 cycles 10 VA 200...250 V 0-60°C 0.4 ) || AC-15 500000 cycles 50 VA 200...250 V 0-60°C 0.4 ) || AC-15 200000 cycles 110 VA 200...250 V 0-60°C 0.4 ) || AC-15 150000 cycles 220 VA 200...250 V 0-60°C 0.4 ) || DC-12 200000 cycles 24 W 24 V 0-60°C || DC-12 150000 cycles 48 W 24 V 0-60°C || DC-12 150000 cycles 40 W 48...60 V 0-60°C || DC-12 100000 cycles 45 W 100...125 V 0-60°C || DC-13 100000 cycles 10 W 24 V 0-60°C || DC-13 60000 cycles 24 W 24 V 0-60°C || DC-13 40000 cycles 48 W 24 V 0-60°C || DC-13 40000 cycles 40 W 48...60 V 0-60°C || DC-13 100000 cycles 15 W 100...125 V 0-60°C
Typical Current Consumption
40 mA 3.3 V DC || 101 mA 24 V DC
Output Overvoltage Protection
use discharge diode on each output DC || use RC circuit on each output AC || use ZNO surge limiter on each output AC
Output Short-Circuit Protection
use 1 fast blow fuse per channel or group of channel
Output Overload Protection
use 1 fast blow fuse per channel or group of channel
Response Time On Output
<= 10 ms activation || <= 13 ms deactivation

Specifications

Range Of Product
Modicon X80
Discrete Output Number
8 EN/IEC 61131-2
Discrete Output Logic
positive or negative
Discrete Output Voltage
5...125 V 5...150 V DC || 24...240 V 19...264 V AC
Product Or Component Type
relay discrete output module

Environment

Shock Resistance
30 gn
Dielectric Strength
1780 V AC 50/60 Hz 1 min
Vibration Resistance
3 gn
Relative Humidity
0-95 % 0-60°C without condensation
Operating Altitude
0...6561.68 ft (0...2000 m) || 2000...5000 m with derating factor
Ip Degree Of Protection
IP20

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products