SCHNEIDER-ELECTRIC ABLP1A24100-Dropship Automation

SCHNEIDER-ELECTRIC ABLP1A24100

SKU: DA-275907
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number ABLP1A24100 UNSPSC 39121004 Tariff Code 8504409530 Country of Origin CN Complementary Output Coupling parallel || serial Height 50 mm Residual Ripple < 150 mV Status Led 1 LED (Green) output voltage Holding Time >; 20 ms 115 V AC || >; 40 ms 230 V AC Efficiency At Full Load 85...264 V AC Earthing System TN...

Additional Information

Part Number
ABLP1A24100
UNSPSC
39121004
Tariff Code
8504409530
Country of Origin
CN

Complementary

Output Coupling
parallel || serial
Height
50 mm
Residual Ripple
< 150 mV
Status Led
1 LED (Green) output voltage
Holding Time
>; 20 ms 115 V AC || >; 40 ms 230 V AC
Efficiency At Full Load
85...264 V AC
Earthing System
TN || TT || IT
Connections - Terminals
screw connection 0.75...2.5 mm², AWG 18...AWG 14) without wire end ferrule || screw connection 0.75...1.5 mm², AWG 18...AWG 16) with wire end ferrule
Dielectric Strength
3000 V AC with input to output
Network Frequency Limits
50-60 Hz
Current Consumption
< 3.6 A 115 V AC || < 1.8 A 230 V AC
Supply
SELV IEC 60950-1 || SELV IEC 60204-1 || SELV IEC 60364-4-41
Net Weight
0.85 kg
Maximum Leakage Current
1 mA 240 V AC
Input Protection Type
integrated fuse (not interchangeable) 6.3 A
Output Protection Type
against overload and short-circuits automatic reset || against over temperature manual reset || against overvoltage manual reset
Service Life
10 year(s)
Meantime Between Failure [Mtbf]
700000 h at 25°C, full load conforming to SR 332
Power Dissipation In W
36 W
Output Voltage Limits
21.6...26.4 V
Mounting Support
top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || double-profile DIN rail || panel mounting
Load Capacitance
8000 µF
Response Time
< 1.2 s
Line And Load Regulation
< 0.5 % network 0 to 100 % load at 25°C || < 1 % network full voltage range in line at 25°C
Width
93 mm
Overvoltage Category
II
Inrush Current
35 A 115 V || 60 A 230 V
Efficiency
87 % 230 V AC
Depth
190 mm
Power Factor
0.95 at 115 V AC || 0.91 at 230 V AC

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2007017EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI2007017EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Standards
IEC 62368-1 || EN/IEC 61010-1 || EN 61010-2-201 || EN/IEC 61204-3 || IEC 61000-6-1 || IEC 61000-6-2 || IEC 61000-6-3 || IEC 61000-6-4 || IEC 61000-3-2 || EN 61000-3-3 || UL 62368-1 || UL 61010-1 || UL 61010-2-201 || CSA C22.2 No 62368-1 || CSA C22.2 No 61010-1 || CSA C22.2 No 61010-2-201 || IEC 60335-1 || EN/IEC 62368-1
Ambient Air Temperature For Operation
-10-50°C without derating mounting position A, B, C, D, F, G < 6561.68 ft (2000 m) || 50-70°C with current derating of 2.5 % per°C mounting position A, B, C, D, F, G < 6561.68 ft (2000 m) || 50-70°C with current derating of 2.5 % per°C < 6561.68 ft (2000 m)
Product Certifications
CE || cULus || EAC || RCM || CB Scheme || KC
Pollution Degree
2
Electromagnetic Compatibility
immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 || immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 || immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 || immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 || immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 || immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 || surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 || surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 || immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 || immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 || immunity to voltage dips conforming to IEC 61000-4-11 || disturbing field emission conforming to EN 55016-2-3 || limits for harmonic current emissions conforming to IEC 61000-3-2 || conforming to EN 55016-1-2 || conforming to EN 55016-2-1
Shock Resistance
150 m/s² 11 ms
Vibration Resistance
3 mm 2-9 Hz)IEC 60068-2-6 || 10 m/s² 9-200 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP10
Operating Altitude
5000 m
Electrical Shock Protection Class
class I
Electromagnetic Emission
conducted emissions IEC 61000-6-3 || radiated emissions IEC 61000-6-4

Specifications

Range Of Product
Modicon Power Supply
Output Voltage
24 V DC
Product Or Component Type
power supply
Power Supply Type
regulated switch mode
Input Voltage
100...240 V AC single phase
Power Supply Output Current
10 A
Kw Rating
240 W
Enclosure Material
Aluminum

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products