SCHNEIDER-ELECTRIC A9F79210-Dropship Automation

SCHNEIDER-ELECTRIC A9F79210

SKU: DA-289111
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number A9F79210 Contractual Warranty Warranty Period 18 months Environment IP Degree of Protection IP20 conforming to EN 60529 || IP20 conforming to IEC 60529 Pollution Degree 3 conforming to EN 60947-2 || 3 conforming to IEC 60947-2 Overvoltage Category IV Tropicalisation 2 conforming to IEC 60068-1 Relative Humidity 95 % ( 55°C ) Operating Altitude 0...2000 m...

Additional Information

Part Number
A9F79210

Contractual Warranty

Warranty Period
18 months

Environment

IP Degree of Protection
IP20 conforming to EN 60529 || IP20 conforming to IEC 60529
Pollution Degree
3 conforming to EN 60947-2 || 3 conforming to IEC 60947-2
Overvoltage Category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative Humidity
95 % ( 55°C )
Operating Altitude
0...2000 m
Ambient Air Temperature for Operation
-35...70°C
Ambient Air Temperature for Storage
-40...85°C

Offer Sustainability

Sustainable Offer Status
Green Premium product
Product Environmental Profile
Available
Product End of Life Instructions
Need no specific recycling operations

Complementary

Network Frequency
50/60 Hz
Magnetic Tripping Limit
8 x In +/- 20 %
[Ics] Rated Service Breaking Capacity
6000 A 100 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz || 10 kA 100 % x Icu conforming to IEC 60947-2 - 72...125 V DC || 10 kA 100 % x Icu conforming to EN 60947-2 - 72...125 V DC || 6000 A 100 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz || 4.5 kA 75 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz || 15 kA 75 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz || 7.5 kA 75 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz || 4.5 kA 75 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz || 15 kA 75 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz || 7.5 kA 75 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz || 27 kA 75 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz || 27 kA 75 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
Limitation Class
3 conforming to EN 60898-1 || 3 conforming to IEC 60898-1
[Ui] Rated Insulation Voltage
500 V AC 50/60 Hz conforming to IEC 60947-2 || 500 V AC 50/60 Hz conforming to EN 60947-2
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to EN 60947-2 || 6 kV conforming to IEC 60947-2
Contact Position Indicator
Yes
Control Type
Toggle
Local Signalling
Trip indicator
Mounting Mode
Fixed
Mounting Support
DIN rail
Comb Busbar and Distribution Block Compatibility
YES top or bottom
9 mm Pitches
4
Height
85 mm
Width
36 mm
Depth
78.5 mm
Product Weight
0.25 kg
Colour
White
Mechanical Durability
20000 cycles
Electrical Durability
10000 cycles
Connections - Terminals
Single terminal, top or bottom rigid wire(s) 1...25 mm² max || Single terminal, top or bottom flexible wire(s) 1...16 mm² max
Wire Stripping Length
14 mm top or bottom
Tightening Torque
2 N.m top or bottom
Earth-leakage Protection
Separate block

Main

Device Application
Distribution
Range
Acti 9
Product Name
Acti 9 iC60
Product or Component Type
Miniature circuit-breaker
Device Short Name
IC60N
Poles Description
2P
Number of Protected Poles
2
[In] Rated Current
10 A
Network Type
AC || DC
Trip Unit Technology
Thermal-magnetic
Curve Code
C
Breaking Capacity
6 kA Icu conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz || 10 kA Icu conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz || 20 kA Icu conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz || 6000 A Icn conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz || 36 kA Icu conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz || 10 kA Icu conforming to EN/IEC 60947-2 - <= 125 V DC || 36 kA Icu conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz
Utilisation Category
Category A conforming to EN 60947-2 || Category A conforming to IEC 60947-2
Suitability for Isolation
Yes conforming to EN 60947-2 || Yes conforming to IEC 60947-2 || Yes conforming to EN 60898-1 || Yes conforming to IEC 60898-1
Standards
EN 60898-1 || EN 60947-2 || IEC 60898-1 || IEC 60947-2

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products