SCHMERSAL 103037574-Dropship Automation

SCHMERSAL 103037574

SKU: DA-447059
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 103037574 ETIM Group Code : EG000019 Group Description : Relays Class Description : Device for monitoring of safety-related circuits Class Code : EC001449 Version : 7 Explosion protection Explosion protection: regulations EN IEC 60079-0 | EN IEC 60079-11 | EN IEC 60079-15 Explosion protection zones 2 Explosion protection category 3G Explosion protection designation II 3 G...

Additional Information

Part Number
103037574
ETIM
Group Code : EG000019
Group Description : Relays
Class Description : Device for monitoring of safety-related circuits
Class Code : EC001449
Version : 7

Explosion protection

Explosion protection: regulations
EN IEC 60079-0 | EN IEC 60079-11 | EN IEC 60079-15
Explosion protection zones
2
Explosion protection category
3G
Explosion protection designation
II 3 G Ex nA nC IIC T5 Gc (Installation SRB, in Zone 2) | II (2) G [Ex ib Gb] IIC | II (2) D [Ex ib Db] IIIC

Electrical data

Operating voltage
24 VDC -10 % / +20 %
Ripple voltage
10 %
Current consumption
57 mA
Rated operating voltage
24 VDC
Rated AC voltage for controls at DC minimum
20.4 VDC
Rated control voltage at DC, maximum
28.8 VDC
Utilisation category AC-15
230 VAC
Utilisation category AC-15
2 A
Utilisation category DC-13
24 VDC
Utilisation category DC-13
2 A
Electrical power consumption
3 W
Contact resistance, maximum
0.1 ©
Note (Contact resistance)
in new state
Drop-out delay in case of power failure, typically
20 ms
Drop-out delay in case of "emergency stop", maximum
20 ms
Pull-in delay at automatic start, maximum, typically
300 ms
Pull-in delay at RESET, typically
20 ms
Material of the contacts, electrical
AgSn0. self-cleaning, positive drive

Note

Note (General)
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Mechanical data - Dimensions

Width
22.5 mm
Height
100 mm
Depth
121 mm

Ambient conditions - Insulation values

Rated impulse withstand voltage U
4 kV
Overvoltage category
III
Degree of pollution
2

General data - Features

Stop-Category
0
Wire breakage detection
Yes
Cross-circuit detection
Yes
Automatic reset function
Yes
Earth connection detection
Yes
Integral system diagnostics, status
Yes
Number of auxiliary contacts
1
Number of LEDs
5
Number of normally closed (NC)
2
Number of safety contacts
1

General data

Climatic stress
EN 60068-2-78
Enclosure material
Glass-fibre reinforced thermoplastic, ventilated
Gross weight
263 g

Safety classification

Standards
EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 61508
Performance Level, stop 0, up to
e
Category, Stop 0
4
Diagnostic Coverage (DC) Level, Stop 0
‰¥ 99 %
PFH value, Stop 0
2.00 x 10�»�¸ /h
Safety Integrity Level (SIL), Stop 0, suitable for applications in
3
Mission time
15 Year(s)
Common Cause Failure (CCF), minimum
65

Wiring example

Note (Wiring diagram)
The wiring diagram is shown with guard doors closed and in de-energised condition. | Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range | If only one external relay or contactor is used to switch the load, the system can be classified in Control Category 3 to ISO 13849-1, if exclusion of the fault œFailure of the external contactor� can be substantiated and is documented, e.g. by using a reliable down-rated contactor. A second contactor leads to an increase in the level of security by redundant switching to switch the load off. | To secure a guard door up to PL e and Category 4 | The feedback circuit monitors the position of the contactors KA and KB. | Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X2. If the feedback circuit is not required, establish a bridge.

Other data

Note (applications)
Safety sensor | Guard system | Emergency-Stop button | Pull-wire emergency stop switches

Ambient conditions

Degree of protection of the enclosure
IP40
Degree of protection of the mounting space
IP54
Degree of protection of clips or terminals
IP20
Ambient temperature
-25 ... +60°C
Storage and transport temperature, minimum
-40°C
Storage and transport temperature, maximum
+85°C
Resistance to vibrations
10 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Terminal designations
IEC/EN 60947-1
Cable section, minimum
0.25 mm²
Cable section, maximum
2.5 mm²
Tightening torque of Clips
0.6 Nm

Mechanical data

Mechanical life, minimum
10,000,000 Operations
Mounting
Snaps onto standard DIN rail to EN 60715

Specifications

Width
22.5 mm
Height
100 mm
Depth
121 mm

Electrical data - Electromagnetic compatibility (EMC)

EMC rating
EMC-Directive

Electrical data - Digital inputs

Conduction resistance, maximum
30 ©

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products