Additional Information
- Part Number
- 103013912
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Position switch with guard locking
- Class Code : EC002593
- Version : 7
Electrical data - Fail-safe digital outputs
- Rated operating current (safety outputs)
- 250 mA
- Voltage drop U
- 4 V
- Current leakage I
- 0.5 mA
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.25 A
- Classification ZVEI CB24I, Source
- C2
- Classification ZVEI CB24I, Sink
- C1 | C2
Safety appraisal - Guard locking
- Performance level, up to
- d
- Control category
- 2
- PFH-value
- 1.00 x 10?? /h
- PFD value
- 8.90 x 10??
- Safety Integrity Level (SIL), suitable for applications in
- 2
- Mission Time
- 20 Year(s)
Safety appraisal
- Standards
- IEC 62061 | IEC 61508 | EN ISO 13849-1
Electrical data
- Operating voltage, minimum
- 20.4 VDC
- Operating voltage, maximum
- 26.4 VDC
- No-load supply current I
- 50 mA
- Current consumption with solenoid ON, average
- 200 mA
- Current consumption with solenoid ON, peak
- 700 mA / 100 ms
- Operating current
- 1,200 mA
- Switching frequency, approx.
- 1 Hz
Electrical data - Fail-safe digital inputs
- Switching thresholds
- ?3 V … 5 V (Low) | 15 V … 30 V (High)
- Classification ZVEI CB24I, Sink
- C1
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
Safety appraisal - Interlocking
- Performance level, up to
- e
- Control category
- 4
- PFH-value
- 1.90 x 10?? /h
- PFD value
- 1.60 x 10??
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission Time
- 20 Year(s)
Mechanical data - Dimensions
- Length of sensor
- 50 mm
- Width of sensor
- 40 mm
- Height of sensor
- 220 mm
Electrical data - Solenoid control
- Switching thresholds
- -3 V … 5 V (Low) | 15 V … 30 V (High)
- Classification ZVEI CB24I, Sink
- C0
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
Scope of delivery
- Included in delivery
- Actuators must be ordered separately. | Triangular key for AZM 201
Ambient conditions - Insulation value
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution to VDE 0100
- 3
General data - Features
- Power to unlock
- Yes
- Guard locking monitored
- Yes
- Manual release
- Yes
- Short circuit detection
- Yes
- Short-circuit recognition
- Yes
- Series-wiring
- Yes
- Safety functions
- Yes
- Integral System Diagnostics, status
- Yes
- Number of safety contacts
- 2
General data
- Standards
- IEC 60947-5-1 | EN ISO 13849-1 | IEC 61508 | IEC 60947-5-3 | EN ISO 14119 | IEC 62061
- General information
- Universal coding
- Coding level according to ISO 14119
- Low
- Active principle
- RFID
- Enclosure material
- Glass-fibre, reinforced thermoplastic
- Gross weight
- 566.1 g
- Time to readiness, maximum
- 4,000 ms
- Duration of risk, maximum
- 200 ms
- Response time safety outputs in case of switch-off by actuator, maximum
- 100 ms
- Response time safety outputs in case of switch-off by safety inputs, maximum
- 0.5 ms
Ambient conditions
- Degree of protection
- IP66 to EN 60529 | IP67 to EN 60529
- Ambient temperature, minimum
- -25 °C
- Ambient temperature, maximum
- +60 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +85 °C
- Relative humidity, minimum
- 30 %
- Relative humidity, maximum
- 95 %
- Note (Relative humidity)
- non-condensing
- Resistance to vibrations to EN 60068-2-6
- 10 … 150 Hz, amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
- Protection rating
- III
Electrical data - Diagnostic output
- Operating current
- 50 mA
- Voltage drop U
- 4 V
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.05 A
Mechanical data - Connection technique
- Terminal Connector
- Spring pulley connection
- Cable section, minimum
- 0.25 mm²
- Cable section, maximum
- 1.5 mm²
- Note (Cable section)
- All indications about the cable section are including the conductor ferrules.
- Wire cross-section, minimum
- 23 AWG
- Wire cross-section, maximum
- 15 AWG
Mechanical data
- Mechanical life, minimum
- 1,000,000 Operations
- Clamping force in accordance with EN ISO 14119 F
- 2,000 N
- Clamping force, maximum F
- 2,600 N
- Latching force
- 30 N
- Actuating speed, maximum
- 0.2 m/s
Accessory
- Recommendation (actuator)
- AZ/AZM201-B1 | AZ/AZM201-B30
Approval - Standards
- Certificates
- TÜV | cULus | EAC | FCC | IC
Status indication
- Note (LED switching conditions display)
- Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green