Additional Information Part Number 103013301 ETIM Group Code : EG000026 Group Description : Sensors Class Description : End switch Class Code : EC000030 Version : 7 Electrical data - Fail-safe digital outputs Versions p-type Voltage drop U 1 V Current leakage I 0.5 mA Voltage, Utilisation category DC-12 24 VDC Current, Utilisation category DC-12 0.25 A Voltage, Utilisation category DC-13...

Additional Information

Part Number
103013301
ETIM
Group Code : EG000026
Group Description : Sensors
Class Description : End switch
Class Code : EC000030
Version : 7

Electrical data - Fail-safe digital outputs

Versions
p-type
Voltage drop U
1 V
Current leakage I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A

Safety appraisal

Standards
EN ISO 13849-1 | IEC 60947-5-3 | EN 62061 | IEC 61508
Performance level, up to
e
Control category to EN13849
4
PFH-value
6.80 x 10�»¹�° /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission Time
20 Year(s)

Electrical data

Voltage type
DC (direct current)
No-load supply current I
100 mA
Rated operating voltage
24 VDC -15% / +10%
Rated operating voltage, minimum
20.4 VDC
Rated operating voltage, maximum
26.4 VDC
Operating current
600 mA
Required rated short-circuit current to EN 60947-5-1
100 A
Switching frequency, approx.
1 Hz

Mechanical data - Dimensions

Length of sensor
29.5 mm
Width of sensor
39.2 mm
Height of sensor
18 mm

Pin assignment

PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
without function

Ambient conditions - Insulation value

Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution to VDE 0100
3

General data - Features

Short circuit detection
Yes
Short-circuit recognition
Yes
Safety functions
Yes
Number of poles
8

General data

Standards
IEC 60947-5-3
General information
Individual coding, multiple teaching
Coding level according to ISO 14119
High
Active principle
RFID
Housing construction form
Block
Installation conditions (mechanical)
not flush
Enclosure material
Plastic, thermoplastic, self-extinguishing
Active area
Glass-fibre, thermoplastic
Gross weight
85 g
Time to readiness, maximum
2,000 ms
Duration of risk, maximum
200 ms

Ambient conditions

Degree of protection
IP65 to EN 60529 | IP67 to EN 60529
Ambient temperature, minimum
-25°C
Ambient temperature, maximum
+65°C
Storage and transport temperature, minimum
-25°C
Storage and transport temperature, maximum
+85°C
Resistance to vibrations to EN 60068-2-6
10 ¦ 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms

Electrical data - Diagnostic output

Operating current
50 mA
Versions
p-type
Voltage drop U
2 V
Current, Utilisation category DC-12
0.05 A
Current, Utilisation category DC-13
0.05 A

Mechanical data - Connection technique

Terminal Connector
Connector M8, 8-pole
Note
The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Switching distances according IEC 60947-5-3

Ensured switching distance "ON", front
10 mm
Ensured switching distance "OFF", front
18 mm
Ensured switching distance "ON", side
6 mm
Ensured switch distance "OFF" S
15 mm

Mechanical data

Actuating panels
lateral | front side
Active area
lateral | front
Hysteresis (Switch distance), maximum
2 mm
Repeat accuracy R R
0.5 mm
Mounting
A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws.

Accessory

Recommendation (actuator)
RST16-1 | RST-U-2 | RST260-1

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation
IEC 61000-6-4
EMC rating
IEC 60947-3

Approval - Standards

Certificates
TÜV | cULus | EAC | FCC | IC

Status indication

Note (LED switching conditions display)
(1) LED green: Supply voltage | LED yellow: Operating condition

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products