Additional Information
- Part Number
- 103005918
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Position switch with guard locking
- Class Code : EC002593
- Version : 7
Safety appraisal
- Standards
- IEC 61508
- Performance level, up to
- e
- Control category to EN13849
- 4
- PFH-value
- 4.00 x 10?¹? /h
- PFD value
- 7.00 x 10??
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission Time
- 20 Year(s)
Electrical data - AS-Interface specification
- AS-i Specification
- Safety-Slave
- AS-i Version
- V 3.0
- AS-i Profile
- S-7.B.F.E
- AS-i Input, Channel 1
- Data bits DI 0 / DI 1 = dynamic code transmission
- AS-i Input, Channel 2
- Data bits DI 2 / DI 3 = dynamic code transmission
- AS-i Outputs, DO 0
- Solenoid control
- AS-i Outputs, DO 1
- No Function
- AS-i Outputs, DO 2
- No Function
- AS-i Outputs, DO 3
- No Function
- AS-i Parameter bits, P0
- Safety guard closed and can be locked
- AS-i Parameter bits, P1
- Solenoid interlock locked
- AS-i Parameter bits, P2
- Auxiliary voltage in
- AS-i Parameter bits, P3
- Internal device error (FID)
- Note (AS-i Parameter bits)
- Set the parameter outputs to "1111" (0xF) | FID: periphery error
- AS-i Input module address
- 0
- Note (AS-i Input module address)
- Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Mechanical data - Dimensions
- Length of sensor
- 34.4 mm
- Width of sensor
- 87.4 mm
- Height of sensor
- 102.6 mm
Pin assignment
- PIN 1
- AS-Interface +
- PIN 2
- Aux - (P)
- PIN 3
- AS-Interface -
- PIN 4
- Aux + (P)
Scope of delivery
- Included in delivery
- Actuators must be ordered separately.
Ambient conditions - Insulation value
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution to VDE 0100
- 3
General data - Features
- Power to unlock
- Yes
- Guard locking monitored
- Yes
- Latching
- Yes
- Manual release
- Yes
- Safety functions
- Yes
- Integral System Diagnostics, status
- Yes
- Number of actuating directions
- 3
General data
- Standards
- IEC 61508 | EN 60947-5-1 | EN ISO 14119 | EN 62026-2 | EN ISO 13849-1
- General information
- Individual coding, multiple teaching
- Coding level according to ISO 14119
- High
- Active principle
- RFID
- Enclosure material
- Glass-fibre, reinforced thermoplastic
- Gross weight
- 595 g
- Time to readiness, maximum
- 5,000 ms
- Reaction time, maximum
- 120 ms
- Duration of risk, maximum
- 200 ms
Electrical data - AS Interface
- AS-i Operating voltage, minimum
- 18 VDC
- AS-i Operating voltage AS-i maximum
- 31.6 VDC
- Note (AS-i Operating voltage)
- Protection against polarity reversal
- AS-i Current consumption, maximum
- 100 mA
Ambient conditions
- Degree of protection
- IP66 to EN 60529 | IP67 to EN 60529 | IP69K to DIN 40050-9
- Ambient temperature, minimum
- +0 °C
- Ambient temperature, maximum
- +60 °C
- Storage and transport temperature, minimum
- -10 °C
- Storage and transport temperature, maximum
- +90 °C
- Resistance to vibrations to EN 60068-2-6
- 10 … 150 Hz, amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
- Protection rating
- II
Mechanical data - Connection technique
- Terminal Connector
- Connector plug M12, 4-pole, (A-coding)
Mechanical data - Switching distances according IEC 60947-5-3
- Switch distance
- 2 mm
- Ensured switch distance "ON" S
- 1 mm
- Ensured switch distance "OFF" S
- 20 mm
Mechanical data
- Mechanical life, minimum
- 1,000,000 Operations
- Note (Mechanical lifetime)
- When using as door stop: ? 50.000 operations (door mass ? 5 kg and actuating speed ? 0.5 m/s)
- Clamping force
- 1,150 N
- Latching force, adjustable, position 1
- 25 N
- Latching force, adjustable, position 2
- 50 N
Accessory
- Recommendation (actuator)
- AZ/AZM300-B1
Electrical data - Auxiliary voltage
- Rated operating voltage
- 24 VDC -15% / +10% (stabilised PELV)
- Operating current
- 300 mA
Approval - Standards
- Certificates
- TÜV | cULus | ASi-SaW | ECOLAB | EAC | FCC
Status indication
- Note (LED switching conditions display)
- (1) green/red LED (AS-i duo LED): Supply voltage/communication error/slave address = 0/periphery error detected/device error detected/manipulation protection active | (2) LED yellow: Device condition (Enabling status) | (3) LED red: Internal device error