Additional Information
- Part Number
- 103001451
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Position switch with guard locking
- Class Code : EC002593
- Version : 7
Electrical data - Fail-safe digital outputs
- Versions
- short-circuit proof, p-type
- Voltage drop U
- 4 V
- Current leakage I
- 0.5 mA
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.25 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.25 A
- Test pulse duration, maximum
- 0.5 ms
- Test pulse interval, typical
- 1000 ms
- Classification ZVEI CB24I, Source
- C2
- Classification ZVEI CB24I, Sink
- C1 | C2
Electrical data - Serial diagnostic SD
- Operation current
- 150 mA
- Wiring capacity
- 50 nF
Safety appraisal
- Standards
- EN ISO 13849-1 | IEC 61508
Electrical data
- Operating voltage, minimum
- 20.4 VDC
- Operating voltage, maximum
- 26.4 VDC
- Notes (Power supply, general)
- stabilised PELV power supply
- No-load supply current I
- 100 mA
- Current consumption with solenoid ON, average
- 200 mA
- Current consumption with solenoid ON, peak
- 350 mA / 200 ms
- Required rated short-circuit current to EN 60947-5-1
- 100 A
- External wiring and device fuse rating
- 2 A gG
- Switching frequency, maximum
- 0.5 Hz
Electrical data - Fail-safe digital inputs
- Switching thresholds
- ˆ’3 V ¦ 5 V (Low) | 15 V ¦ 30 V (High)
- Current consumption at 24V
- 5 mA
- Test pulse duration, maximum
- 1 ms
- Test pulse interval, minimum
- 100 ms
- Classification ZVEI CB24I, Sink
- C1
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
Safety appraisal - Interlocking
- Performance level, up to
- e
- Control category
- 4
- PFH-value
- 5.20 x 10�»¹�° /h
- PFD value
- 4.50 x 10�»�µ
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission Time
- 20 Year(s)
Mechanical data - Dimensions
- Length of sensor
- 120 mm
- Width of sensor
- 87.5 mm
- Height of sensor
- 35 mm
Electrical data - Solenoid control
- Switching thresholds
- -3 V ¦ 5 V (Low) | 15 V ¦ 30 V (High)
- Duty cycle solenoid
- 100 %
- Test pulse duration, maximum
- 5 ms
- Test pulse interval, minimum
- 40 ms
- Classification ZVEI CB24I, Sink
- C0
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
Pin assignment
- PIN 1
- A1 Supply voltage UB
- PIN 2
- X1 Safety input 1
- PIN 3
- A2 GND
- PIN 4
- Y1 Safety output 1
- PIN 5
- OUT serial diagnostic output
- PIN 6
- X2 Safety input 2
- PIN 7
- Y2 Safety output 2
- PIN 8
- IN serial diagnostic input
Scope of delivery
- Included in delivery
- Actuators must be ordered separately.
Ambient conditions - Insulation value
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution to IEC/EN 60664-1
- 3
General data - Features
- Power to lock
- Yes
- Guard locking monitored
- Yes
- Serial diagnostics
- Yes
- Latching
- Yes
- Manual release
- Yes
- Short circuit detection
- Yes
- Short-circuit recognition
- Yes
- Series-wiring
- Yes
- Safety functions
- Yes
- Integral System Diagnostics, status
- Yes
- Number of fail-safe digital outputs
- 2
General data
- Standards
- IEC 61508 | IEC 60947-5-3 | EN ISO 13849-1 | EN ISO 14119
- General information
- Universal coding
- Coding level according to ISO 14119
- Low
- Active principle
- RFID
- Frequency band RFID
- 125 kHz
- Transmit power, maximum
- -6 dB/m
- Enclosure material
- Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Gross weight
- 550 g
- Time to readiness, maximum
- 5,000 ms
- Duration of risk, maximum
- 200 ms
- Response time safety outputs in case of switch-off by actuator, maximum
- 100 ms
- Response time safety outputs in case of switch-off by safety inputs, maximum
- 1.5 ms
Ambient conditions
- Degree of protection
- IP66 to EN 60529 | IP67 to EN 60529 | IP69 to EN 60529
- Ambient temperature, minimum
- +0°C
- Ambient temperature, maximum
- +60°C
- Storage and transport temperature, minimum
- -10°C
- Storage and transport temperature, maximum
- +90°C
- Relative humidity, maximum
- 93 %
- Note (Relative humidity)
- non-condensing | non-icing
- Resistance to vibrations to EN 60068-2-6
- 10 ¦ 150 Hz, amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
- Protection rating
- III
- Zulässige Aufstellhöhe über NN, maximum
- 2,000 m
Electrical data - Diagnostic output
- Versions
- short-circuit proof, p-type
- Voltage drop U
- 4 V
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.05 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.05 A
Mechanical data - Connection technique
- Terminal Connector
- Connector M12, 8-pole, A-coded
- Length of sensor chain, maximum
- 200 m
- Note (length of the sensor chain)
- Cable length and cross-section change the voltage drop dependiing on the output current
- Note (series connection of the sensors)
- Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Mechanical data - Switching distances according IEC 60947-5-3
- Switch distance
- 2 mm
- Ensured switch distance "ON" S
- 1 mm
- Ensured switch distance "OFF" S
- 20 mm
Mechanical data
- Mechanical life, minimum
- 1,000,000 Operations
- Note (Mechanical lifetime)
- When using as door stop: ‰¥ 50.000 operations (door mass ‰¤ 5 kg and actuating speed ‰¤ 0.5 m/s)
- Angular offset between interlocking device and actuator, maximum
- 2°
- Clamping force in accordance with EN ISO 14119 F
- 1,150 N
- Clamping force, maximum F
- 1,500 N
- Latching force, adjustable, position 1
- 25 N
- Latching force, adjustable, position 2
- 50 N
- Type of the fixing screws
- 2x M6
- Tightening torque of the fixing screws, minimum
- 6 Nm
- Tightening torque for the fixing screws, maximum
- 7 Nm
Accessory
- Recommendation (actuator)
- AZ/AZM300-B1
Approval - Standards
- Certificates
- TÜV | cULus | ECOLAB | EAC | FCC | IC
Status indication
- Note (LED switching conditions display)
- Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green