Additional Information
- Part Number
- 101216956
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : End switch
- Class Code : EC000030
- Version : 7
Electrical data - Fail-safe digital outputs
- Rated operating current (safety outputs)
- 250 mA
- Output current, (fail-safe output), maximum
- 0.25 A
- Versions
- p-type
- Voltage drop U
- 1 V
- Current leakage I
- 0.5 mA
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.25 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.25 A
Safety appraisal
- Standards
- EN ISO 13849-1 | IEC 60947-5-3 | EN 62061 | IEC 61508
- Performance level, up to
- e
- Control category to EN13849
- 4
- PFH-value
- 2.70 x 10�»¹�° /h
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission Time
- 20 Year(s)
Electrical data
- Voltage type
- DC (direct current)
- No-load supply current I
- 100 mA
- Rated operating voltage
- 24 VDC ˆ’15 % / +10 %
- Rated operating voltage, minimum
- 20.4 VDC
- Rated operating voltage, maximum
- 26.4 VDC
- Operating current
- 600 mA
- Required rated short-circuit current to EN 60947-5-1
- 100 A
- Switching frequency, approx.
- 1 Hz
Mechanical data - Dimensions
- Length of sensor
- 22 mm
- Width of sensor
- 106.3 mm
- Height of sensor
- 25 mm
Pin assignment
- PIN 1
- A1 Ue Brown
- PIN 2
- X1 Safety input 1 White
- PIN 3
- A2 GND Blue
- PIN 4
- Y1 Safety output 1 Black
- PIN 5
- OUT Diagnostic output OUT Grey
- PIN 6
- X2 Safety input 2 violet
- PIN 7
- Y2 Safety output 2 red
- PIN 8
- IN without function Pink
Scope of delivery
- Included in delivery
- Actuators must be ordered separately.
Ambient conditions - Insulation value
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution to VDE 0100
- 3
General data - Features
- Diagnostic output
- Yes
- Short circuit detection
- Yes
- Short-circuit recognition
- Yes
- Safety functions
- Yes
- Cascadable
- Yes
- Integral System Diagnostics, status
- Yes
- Number of LEDs
- 3
- Number of semi-conductor outputs with signaling function
- 1
- Number of fail-safe digital outputs
- 2
General data
- Standards
- IEC 60947-5-3
- General information
- Individual coding, multiple teaching
- Coding level according to ISO 14119
- High
- Active principle
- RFID
- Housing construction form
- Block
- Installation conditions (mechanical)
- not flush
- Sensor topology
- Sensor for series wiring
- Enclosure material
- Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Active area
- Glass-fibre, reinforced thermoplastic
- Gross weight
- 80 g
- Time to readiness, maximum
- 2,000 ms
- Reaction time, maximum
- 100 ms
- Duration of risk, maximum
- 200 ms
Ambient conditions
- Degree of protection
- IP65 to EN 60529 | IP67 to EN 60529 | IP69 to EN 60529
- Ambient temperature, minimum
- -25°C
- Ambient temperature, maximum
- +70°C
- Storage and transport temperature, minimum
- -25°C
- Storage and transport temperature, maximum
- +85°C
- Material temperature resistance of the cable (in motion), minimum
- -10°C
- Material temperature resistance of the cable (at rest), minimum
- -30°C
- Material temperature resistance (long-term), maximum
- +105°C
- Resistance to vibrations to EN 60068-2-6
- 10 ¦ 55 Hz, amplitude 1 mm
- Restistance to shock
- 30 g / 11 ms
- Protection rating
- III
Electrical data - Diagnostic output
- Versions
- p-type
- Voltage drop U
- 2 V
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.05 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.05 A
Mechanical data - Connection technique
- Terminal Connector
- Connector M12, 8-pole
- Note
- The cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current
Mechanical data - Switching distances according IEC 60947-5-3
- Switch distance
- 12 mm
- Ensured switch distance "ON" S
- 10 mm
- Ensured switch distance "OFF" S
- 20 mm
Mechanical data
- Actuating panels
- lateral
- Active area
- lateral
- Hysteresis (Switch distance), maximum
- 2 mm
- Repeat accuracy R R
- 0.5 mm
- Note (Repeat accuracy
- Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm.
- Mounting
- A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.
Accessory
- Recommendation (actuator)
- RST 36-1 | RST 36-1-R
- Recommended safety switchgear
- PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC
Electrical data - Electromagnetic compatibility (EMC)
- Interfering radiation
- IEC 61000-6-4
- EMC rating
- IEC 60947-3
Approval - Standards
- Certificates
- TÜV | cULus | ECOLAB | EAC | FCC | IC
Status indication
- Note (LED switching conditions display)
- LED yellow: Operating condition | LED green: Supply voltage | LED red: Fault