Additional Information Part Number 101210927 ETIM Group Code : EG000026 Group Description : Sensors Class Description : Position switch with guard locking Class Code : EC002593 Version : 7 Electrical data - AS-Interface specification AS-i Specification Safety-Slave AS-i Version V 2.1 AS-i Profile S-7.B.F.E AS-i, IO-Code 0x7 AS-i, ID-Code 0xB AS-i, ID-Code1 0xF AS-i, ID-Code2 0xE AS-i Input, Channel 1...

Additional Information

Part Number
101210927
ETIM
Group Code : EG000026
Group Description : Sensors
Class Description : Position switch with guard locking
Class Code : EC002593
Version : 7

Electrical data - AS-Interface specification

AS-i Specification
Safety-Slave
AS-i Version
V 2.1
AS-i Profile
S-7.B.F.E
AS-i, IO-Code
0x7
AS-i, ID-Code
0xB
AS-i, ID-Code1
0xF
AS-i, ID-Code2
0xE
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Outputs, DO 0
Solenoid control
AS-i Outputs, DO 1
No Function
AS-i Outputs, DO 2
No Function
AS-i Outputs, DO 3
No Function
AS-i Parameter bits, P0
Safety guard and actuator detected
AS-i Parameter bits, P1
Solenoid interlock locked
AS-i Parameter bits, P2
No function
AS-i Parameter bits, P3
No function
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF) | FID: periphery error
AS-i Input module address
0
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Note

Note (General)
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened.

Mechanical data - Dimensions

Width of sensor
90 mm
Height of sensor
75.5 mm

Pin assignment

PIN 1
AS-i +
PIN 2
Aux - (P)
PIN 3
AS-Interface -
PIN 4
Aux + (P)

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

General data - Features

Power to unlock
Yes
Actuator monitored
Yes
Integral system diagnostics, status
Yes
Number of actuating directions
2

General data

Standards
EN IEC 62026-2 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 61508
Working principle
electromechanical
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight
285 g
Reaction time, maximum
100 ms

Safety classification

Standards
EN IEC 61508
Performance Level, up to
c
Category
1
PFH value
1.16 x 10�»�¶ /h
Note (PFH-value)
up to max. 100,000 switching cycles/year
Safety Integrity Level (SIL), suitable for applications in
1
Mission time
20 Year(s)
Please note:
Einsetzbar wenn ein Fehlerausschluss f¼r eine gefahrbringende Besch¤digung der 1-kanaligen Mechanik zul¤ssig ist und ein ausreichender Manipulationsschutz gew¤hrleistet ist.
Performance Level, up to
d
Category
3
PFH value
1.01 x 10�»�· /h
Safety Integrity Level (SIL), suitable for applications in
2

Electrical data - AS Interface

Rated operating voltage
26.5 ... 31.6 VDC (Protection against polarity reversal)
AS-i Current consumption, maximum
100 mA

Ambient conditions

Degree of protection
IP67
Ambient temperature
-25 ... +55C
Storage and transport temperature, minimum
-25C
Storage and transport temperature, maximum
+85C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %
Note (Relative humidity)
non-condensing | non-icing
Protection class
II

Mechanical data - Connection technique

Termination
Connector plug M12, 4-pole, (A-coding)

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Holding force
1,000 N
Latching force
30 N
Actuating speed, maximum
2 m/s

Approvals - Standards

Certificates
TœV | cULus | ASi-SaW

Electrical data - Auxiliary voltage

Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
Current consumption
500 mA
Rated operating voltage
24 VDC

Status indication

Note (LED switching conditions display)
(1) LED green: Supply voltage | (2) red LED: Communication error / Slave address = 0 | (3) LED yellow : Enabling status

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products