Dropship Automation

SCHMERSAL 101182561

SKU: DA-803892
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 101182561 ETIM Group Code : EG000024 Group Description : PLC's Class Description : Fieldbus, decentr. periphery - digital I/O module Class Code : EC001599 Version : 7 Electrical data Current consumption 50 mA Electrical data - AS-Interface specification AS-i Version V 2.1 AS-i Profile S-0.B.F.E AS-i, IO-Code 0x7 AS-i, ID-Code 0xB AS-i, ID-Code1 0xF AS-i, ID-Code2...

Additional Information

Part Number
101182561
ETIM
Group Code : EG000024
Group Description : PLC's
Class Description : Fieldbus, decentr. periphery - digital I/O module
Class Code : EC001599
Version : 7

Electrical data

Current consumption
50 mA

Electrical data - AS-Interface specification

AS-i Version
V 2.1
AS-i Profile
S-0.B.F.E
AS-i, IO-Code
0x7
AS-i, ID-Code
0xB
AS-i, ID-Code1
0xF
AS-i, ID-Code2
0xE
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Outputs, DO 0 … DO 3
No Function
AS-i Parameter bits, P0 ... P3
No function
AS-i Parameter bits, P3
Authorised operation canal 1 + 2
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF)
AS-i Input module address
0
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Mechanical data - Dimensions

Diameter of sensor
28 mm
Height of sensor
86.5 mm

Pin assignment

Connection
ST1 male connector / power supply for Safety light grids and curtains
PIN 1
+ 24 VDC
PIN 2
n.c.
PIN 3
GND
PIN 4
n.c.
PIN 5
FE (functional earth connection)
Connection
ST2 female connector / Safety light grids and curtains
PIN 2
OSSD 1
PIN 4
OSSD 2

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

General data - Features

Cross-circuit detection
Yes
Integral system diagnostics, status
Yes
Number of pre-wired cable
2

General data

Standards
EN 50295 | EN ISO 13849-1 | EN IEC 61508 | EN IEC 61496-1
Connector (electric)
AS-i connection: connector plug M12, 4-pole
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight
185 g
Reaction time, maximum
20 ms

Safety classification

Standards
EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
1.74 x 10?? /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - AS Interface

Rated operating voltage
26.5 ... 31.6 VDC (Protection against polarity reversal)

Wiring example

Note (Wiring diagram)
The Opto-Tube is directly connected to the receiver module (ST2). The receiver module is supplied with 24 V DC via the connector (ST1). | The Opto-Tube itself is connected via the M12 connector (ST) to the AS-i network. Before hand the module has to be programmed with an individual address (1 - 31). | The emitter module has to be wired up separately Please observe the corresponding SLC/SLG documentation (test signal). | The wiring diagram shows an active optoelectronic device (AOPD) (type SLC/SLG 420) with a safety input module AST LC ST-AS (Opto-Tube) connected to the AS-i Safety at Work system.

Ambient conditions

Degree of protection
IP67
Ambient temperature
-25 ... +60 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %
Note (Relative humidity)
non-condensing
Protection class
II

Approvals - Standards

Certificates
cULus

Status indication

Note (LED switching conditions display)
(1) LED green: Supply voltage | (2) LED red: Communication error | (3) LED yellow: Enabling status OSSD 1/2

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products