Dropship Automation

SCHMERSAL 101181065

SKU: DA-859529
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 101181065 ETIM Group Code : EG000026 Group Description : Sensors Class Description : End switch Class Code : EC000030 Version : 7 Electrical data No-load supply current I 100 mA Operating current 600 mA Required rated short-circuit current 100 A Note (Electrical data, Fuse rating) (Circuit breaker) Switching frequency, approx. 3 Hz Note Note (General) Evaluation...

Additional Information

Part Number
101181065
ETIM
Group Code : EG000026
Group Description : Sensors
Class Description : End switch
Class Code : EC000030
Version : 7

Electrical data

No-load supply current I
100 mA
Operating current
600 mA
Required rated short-circuit current
100 A
Note (Electrical data, Fuse rating)
(Circuit breaker)
Switching frequency, approx.
3 Hz

Note

Note (General)
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary.

Mechanical data - Dimensions

Length of sensor
35 mm
Width of sensor
27 mm
Height of sensor
108.2 mm

Pin assignment

PIN 1
1A1 Ue: (1)
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output OUT
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN without function

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

General data - Features

Diagnostic output
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Safety functions
Yes
Cascadable
Yes
Integral system diagnostics, status
Yes
Number of LEDs
3
Number of semi-conductor outputs with signaling function
1
Number of fail-safe digital outputs
2
Number of series-wiring of sensors
31

General data

Standards
EN IEC 60947-5-3
Working principle
inductive
Housing construction form
Block
Installation conditions (mechanical)
not flush
Sensor topology
Sensor for series wiring
Enclosure material
Glass-fibre, reinforced thermoplastic
Active area
Glass-fibre, reinforced thermoplastic
Gross weight
140 g
Reaction time, maximum
30 ms
Duration of risk, maximum
60 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
3.60 x 10?? /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Rated operating current (safety outputs)
250 mA
Output current, (fail-safe output), maximum
0.25 A
Design of control elements
p-type
Voltage drop U
0.5 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A

Ambient conditions

Degree of protection
IP65 | IP67
Ambient temperature
-25 ... +70 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms
Protection class
II

Mechanical data - Connection technique

Termination
Connector plug M12, 8-pole
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current

Electrical data - Diagnostic outputs

Design of control elements
p-type
Voltage drop U
5 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Mechanical data - Switching distances according EN IEC 60947-5-3

Nominal switching distance S
10 mm | 12 mm | 15 mm
Assured switching distance "ON" S
10 mm | 13 mm | 8 mm
Assured switching distance "OFF" S
15 mm | 16 mm | 18 mm

Mechanical data

Actuating panels
Actuation from top
Active area
front side
Switching distance actuator
Actuator CST 180-1 / CST 180-2: 10 mm | Actuator CST 180-1 / CST 180-2: 12 mm | Actuator CST 180-1 / CST 180-2: 16 mm | Actuator CST 34-S-2: 10 mm | Actuator CST 34-S-2: 16 mm | Actuator CST 34-S-2: 8 mm | Actuator CST 34-S-3: 13 mm | Actuator CST 34-S-3: 15 mm | Actuator CST 34-S-3: 18 mm | Actuator CST 34-V-1: 10 mm | Actuator CST 34-V-1: 12 mm | Actuator CST 34-V-1: 15 mm
Hysteresis (Switching distance), maximum
1.5 mm
Repeat accuracy R
0.5 mm
Note (Repeat accuracy R)
Axial offset: the front face allows for an axial misalignment (z) of max. ± 8 mm (see figure: operating principle).

Accessory

Recommendation (actuator)
CST 34-V-1 | CST 34-S-2 | CST 34-S-3 | CST 180-1 | CST 180-2
Recommended safety switchgear
PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC

Approvals - Standards

Certificates
TÜV | cULus | UKCA

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation
IEC 61000-6-4
EMC rating
IEC 61000-6-2

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products