Additional Information Part Number 101131305 ETIM Group Code : EG000019 Group Description : Relays Class Description : Device for monitoring of safety-related circuits Class Code : EC001449 Version : 7 Electrical data - Relay outputs (auxiliary contacts) Switching capacity, maximum 24 VDC Switching capacity, maximum 2 A Electrical data Frequency range 50 Hz | 60 Hz Operating voltage 24 VAC...

Additional Information

Part Number
101131305
ETIM
Group Code : EG000019
Group Description : Relays
Class Description : Device for monitoring of safety-related circuits
Class Code : EC001449
Version : 7

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum
24 VDC
Switching capacity, maximum
2 A

Electrical data

Frequency range
50 Hz | 60 Hz
Operating voltage
24 VAC -15 % / +10 %
Ripple voltage
10 %
Thermal test current
6 A
Rated operating voltage
24 VAC
Rated AC voltage for controls, 50 Hz, minimum
20.4 VAC
Rated control voltage at AC 50 Hz, maximum
26.4 VAC
Rated AC voltage for controls, 60 Hz, minimum
20.4 VAC
Rated control voltage at AC 60 Hz, maximum
26.4 VAC
Rated AC voltage for controls at DC minimum
20.4 VDC
Rated control voltage at DC, maximum
28.8 VDC
Electrical power consumption
5 W
Contact resistance, maximum
0.1 ?
Note (Contact resistance)
in new state
Drop-out delay in case of power failure, typically
80 ms
Drop-out delay in case of emergency, typically
20 ms
Pull-in delay at automatic start, maximum, typically
100 ms
Pull-in delay at RESET, typically
20 ms
Material of the contacts, electrical
Ag-Ni 10 and 0.2 µm gold-plated

Note

Note (General)
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Mechanical data - Dimensions

Width
22.5 mm
Height
100 mm
Depth
121 mm

Ambient conditions - Insulation values

Rated impulse withstand voltage U
4 kV
Overvoltage category
III
Degree of pollution
2

Electrical data - Digital Output

Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.1 A

General data - Features

Stop-Category
0
Wire breakage detection
Yes
Cross-circuit detection
Yes
Automatic reset function
Yes
Reset after disconnection of supply voltage
Yes
Earth connection detection
Yes
Integral system diagnostics, status
Yes
Number of auxiliary contacts
2
Number of inputs for NC
2
Number of inputs for NO
1
Number of LEDs
1
Number of safety contacts
1
Number of signalling outputs
2

General data

Standards
BG-GS-ET-14 | BG-GS-ET-20 | EN IEC 62061 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 60947-5-5 | EN IEC 60204-1 | EN IEC 60947-1
Climatic stress
BG-GS-ET-14 | IEC 60947-5-3
Enclosure material
Glass-fibre reinforced thermoplastic, ventilated
Gross weight
164 g

Safety classification

Standards
EN ISO 13849-1 | EN IEC 61508
Performance Level, up to
d
Category
3
PFH value
1.00 x 10?? /h
Notice
for max. 50,000 switching cycles/year and max. 80% contact load
Safety Integrity Level (SIL), suitable for applications in
2
Mission time
20 Year(s)

Wiring example

Note (Wiring diagram)
The wiring diagram is shown with guard doors closed and in de-energised condition. | Monitoring 2 guard door(s), each with a magnetic safety sensor of the BNS range | If one or two external relays or contactors are used to switch the load, the system can then only be classified in Category 3 to EN ISO 13849-1, if exclusion of the fault “Failure of the external contactors” can be substantiated and is documented, e.g. by using reliable down-rated contactors. A second contactor leads to an increase in the level of security by redundant switching to switch the load off. | The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. | Expansion of enable delay time: The enable delay time can be increased from 0.1 s to 1 s by changing the position of a jumper link connection under the cover of the unit. | To secure 2 guard doors up to PL d and Category 3

Other data

Note (applications)
Safety sensor | Guard system

Ambient conditions

Degree of protection of the enclosure
IP40
Degree of protection of the mounting space
IP54
Degree of protection of clips or terminals
IP20
Ambient temperature
+0 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Resistance to vibrations
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Termination
rigid or flexible | Screw terminals M20 x 1.5
Terminal designations
IEC/EN 60947-1
Cable section, minimum
0.25 mm²
Cable section, maximum
2.5 mm²
Tightening torque of Clips
0.6 Nm

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
6 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
6 A
Switching capacity, minimum
10 VDC
Switching capacity, minimum
10 mA
Switching capacity, maximum
250 VAC
Switching capacity, maximum
8 A

Mechanical data

Mechanical life, minimum
20,000,000 Operations
Mounting
Snaps onto standard DIN rail to EN 60715

Specifications

Width
22.5 mm
Height
100 mm
Depth
121 mm

Approvals - Standards

Certificates
cULus

Electrical data - Electromagnetic compatibility (EMC)

EMC rating
EMC-Directive

Electrical data - Digital inputs

Input signal, HIGH Signal "1"
10 … 30 VDC
Input signal, LOW Signal "0"
0 … 2 VDC
Conduction resistance, maximum
40 ?

Integral system diagnosis (ISD)

Note (ISD -Faults)
The following faults are registered by the safety monitoring modules and indicated by ISD.
Faults
Failure of the safety relay to pull-in or drop-out | Failure of door contacts to open or close | Cross-wire or short-circuit monitoring of the switch connections | Interruption of the switch connections | Fault on the input circuits or the relay control circuits of the safety monitoring module

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products