Dropship Automation

SCHMERSAL 101126705

SKU: DA-1088709
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 101126705 ETIM Group Code : EG000019 Group Description : Relays Class Description : Device for monitoring of safety-related circuits Class Code : EC001449 Version : 7 Electrical data - Relay outputs (auxiliary contacts) Switching capacity, maximum 24 VDC Switching capacity, maximum 2 A Electrical data Frequency range 50 Hz | 60 Hz Operating voltage 230 VAC...

Additional Information

Part Number
101126705
ETIM
Group Code : EG000019
Group Description : Relays
Class Description : Device for monitoring of safety-related circuits
Class Code : EC001449
Version : 7

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum
24 VDC
Switching capacity, maximum
2 A

Electrical data

Frequency range
50 Hz | 60 Hz
Operating voltage
230 VAC -15 % / +15 %
Rated operating voltage
230 VAC
Rated AC voltage for controls, 50 Hz, minimum
20.4 VAC
Rated control voltage at AC 50 Hz, maximum
26.4 VAC
Rated AC voltage for controls, 60 Hz, minimum
20.4 VAC
Rated control voltage at AC 60 Hz, maximum
26.4 VAC
Electrical power consumption
5 W
Contact resistance, maximum
0.1 ?
Note (Contact resistance)
in new state
Drop-out delay in case of power failure, typically
80 ms
Drop-out delay in case of emergency, typically
20 ms
Pull-in delay at automatic start, maximum, typically
100 ms
Pull-in delay at RESET, typically
20 ms

Note

Note (General)
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Mechanical data - Dimensions

Width
55 mm
Height
75 mm
Depth
110 mm

Ambient conditions - Insulation values

Rated impulse withstand voltage U
4 kV
Overvoltage category
III
Degree of pollution
2

Electrical data - Digital Output

Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.1 A

General data - Features

Wire breakage detection
Yes
Cross-circuit detection
Yes
Automatic reset function
Yes
Reset after disconnection of supply voltage
Yes
Earth connection detection
Yes
Integral system diagnostics, status
Yes
Number of LEDs
1
Number of normally closed (NC)
1
Number of normally open (NO)
1
Number of undelayed semi-conductor outputs with signaling function
2
Number of safety contacts
3
Number of signalling outputs
2

General data

Standards
BG-GS-ET-20 | EN IEC 62061 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 60947-5-5 | EN IEC 60204-1 | EN IEC 60947-1
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
450 g

Safety classification

Standards
EN IEC 61508
Performance Level, up to
d
Category
3
PFH value
1.00 x 10?? /h
Safety Integrity Level (SIL), suitable for applications in
2
Mission time
20 Year(s)

Wiring example

Note (Wiring diagram)
The wiring diagram is shown with guard doors closed and in de-energised condition. | The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. | To monitor one guard door at plants with dangerous run-on movements up to PL d and Category 3 | Monitoring time for unlocking of solenoid interlocks | The solenoid interlock releases the guard device only when the set time has elapsed. The time begins to run when the power contactors have dropped out.

Other data

Note (applications)
Fail-safe delay timer

Ambient conditions

Degree of protection of the enclosure
IP40
Degree of protection of the mounting space
IP54
Degree of protection of clips or terminals
IP20
Ambient temperature
+0 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Resistance to vibrations
10 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Termination
rigid or flexible | Screw terminals M20 x 1.5
Cable section, maximum
4 mm²
Note (Cable section)
All indications including the conductor ferrules.
Tightening torque of Clips
0.4 Nm

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15
250 VAC
Current, Utilisation category AC-15
2 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
2 A
Switching capacity, minimum
10 VDC
Switching capacity, minimum
10 mA
Switching capacity, maximum
250 VAC
Switching capacity, maximum
8 A

Mechanical data

Mounting
Snaps onto standard DIN rail to EN 60715

Specifications

Width
55 mm
Height
75 mm
Depth
110 mm

Approvals - Standards

Certificates
cULus

Electrical data - Electromagnetic compatibility (EMC)

EMC rating
EMC-Directive

Electrical data - Digital inputs

Input signal, HIGH Signal "1"
10 … 30 VDC
Input signal, LOW Signal "0"
0 … 2 VDC
Conduction resistance, maximum
40 ?

Integral system diagnosis (ISD)

Note (ISD -Faults)
The following faults are registered by the safety monitoring modules and indicated by ISD.
Faults
Failure of the safety relay to pull-in or drop-out | Fault on the input circuits or the relay control circuits of the safety monitoring module | Difference in time setting between channel I and channel II | Cross conclusions to the input lines | Interruption of the input connections

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products