Additional Information
- Part Number
- 2908539
- UPC
- 4055626306490
- ETIM
- Group Code : EG000021
- Group Description : Earthing, lightning and surge protection
- Class Description : Surge protection device for power supply systems
- Class Code : EC000941
- Version : 7
UL indicator/remote signaling
- Operating voltage
- 125 V AC
- Operating current
- 1 A AC
- Tightening torque
- 4 lbf-in.
- Conductor cross section AWG
- 30 - 14
UL specifications
- SPD Type
- 4CA
- Maximum continuous operating voltage MCOV (L-L)
- 1500 V AC
- Maximum continuous operating voltage MCOV (L-G)
- 750 V AC
- Nom. voltage
- 690 V AC
- Mode of protection
- L-L
- Mode of protection
- L-G
- Power distribution system
- Delta
- Nominal frequency
- 50/60 Hz
- Measured limiting voltage MLV (L-L)
- 4810 V
- Measured limiting voltage MLV (L-G)
- 2560 V
- Nominal discharge current In (L-L)
- 10 kA
- Nominal discharge current In (L-G)
- 10 kA
Additional descriptions
- Note
- For use in all low-voltage systems between L-PEN. Only for use in IT systems between L-PE if the bodies of the equipment in the low-voltage system are connected to the grounding system of the transformer station. (common grounding of the HV transformer station and the bodies of the LV consumer's installation. RE = RA according to IEC 60364-4-442/VDE 0100-442 Figure 44D/example a)
Dimensions
- Height
- 98.7 mm
- Width
- 53.4 mm
- Depth
- 65.7 mm (incl. DIN rail 7.5 mm)
- Horizontal pitch
- 3 Div.
Connection data
- Connection method
- Screw connection
- Screw thread
- M5
- Tightening torque
- 3 Nm (1.5 mm² - 16 mm²)
- Tightening torque
- 4.5 Nm (25 mm² - 35 mm²)
- Stripping length
- 16 mm
- Conductor cross section flexible
- 1.5 mm² - 25 mm²
- Conductor cross section solid
- 1.5 mm² - 35 mm²
- Conductor cross section AWG
- 15 - 2
- Connection method
- Fork-type cable lug
- Conductor cross section flexible
- 1.5 mm² - 16 mm²
Indicator/remote signaling
- Switching function
- PDT contact
- Operating voltage
- 5 V AC - 250 V AC
- Operating voltage
- 30 V DC
- Operating current
- 5 mA AC - 1.5 A AC
- Operating current
- 1 A DC
- Connection method
- Plug-in/screw connection via COMBICON
- Screw thread
- M2
- Tightening torque
- 0.25 Nm
- Stripping length
- 7 mm
- Conductor cross section flexible
- 0.14 mm² - 1.5 mm²
- Conductor cross section solid
- 0.14 mm² - 1.5 mm²
- Conductor cross section AWG
- 28 - 16
Ambient conditions
- Degree of protection
- IP20 (only when all terminal points are used)
- Ambient temperature (operation)
- -40°C - 80°C
- Ambient temperature (storage/transport)
- -40°C - 80°C
- Altitude
- ‰¤ 2000 m (amsl (above mean sea level))
- Permissible humidity (operation)
- 5 % - 95 %
- Shock (operation)
- 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
- Vibration (operation)
- 5g (10 - 500 Hz / 2.5 h / X, Y, Z)
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
Protective circuit
- Nominal voltage UN
- 554/960 V AC (TN-C)
- Nominal voltage UN
- 690 V AC (IT)
- Nominal frequency fN
- 50 Hz (60 Hz)
- Maximum continuous voltage UC
- 760 V AC
- Rated load current IL
- 80 A
- Residual current IPE
- ‰¤ 1.5 mA
- Standby power consumption PC
- ‰¤ 1200 mVA
- Nominal discharge current In (8/20) µs
- 15 kA
- Maximum discharge current Imax (8/20) µs
- 30 kA
- Short-circuit current rating ISCCR
- 25 kA
- Voltage protection level Up
- ‰¤ 2.9 kV
- Residual voltage Ures
- ‰¤ 2.9 kV (at In)
- Residual voltage Ures
- ‰¤ 2.7 kV (at 10 kA)
- Residual voltage Ures
- ‰¤ 2.5 kV (at 5 kA)
- Residual voltage Ures
- ‰¤ 2.3 kV (at 3 kA)
- TOV behavior at UT
- 1000 V AC (5 s / withstand mode)
- TOV behavior at UT
- 1056 V AC (120 min / safe failure mode)
- Response time tA
- ‰¤ 25 ns
- Max. backup fuse with V-type through wiring
- 80 A (gG)
- Max. backup fuse with branch wiring
- 100 A (gG)
Standards and Regulations
- Standards/regulations
- IEC 61643-11 2011
- Standards/regulations
- EN 61643-11 2012
UL connection data
- Conductor cross section AWG
- 10 - 2
- Tightening torque
- 30 lbf-in.