PHOENIX-CONTACT 2908539-Dropship Automation

PHOENIX-CONTACT 2908539

SKU: DA-351721
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 2908539 UPC 4055626306490 ETIM Group Code : EG000021 Group Description : Earthing, lightning and surge protection Class Description : Surge protection device for power supply systems Class Code : EC000941 Version : 7 UL indicator/remote signaling Operating voltage 125 V AC Operating current 1 A AC Tightening torque 4 lbf-in. Conductor cross section AWG 30 -...

Additional Information

Part Number
2908539
UPC
4055626306490
ETIM
Group Code : EG000021
Group Description : Earthing, lightning and surge protection
Class Description : Surge protection device for power supply systems
Class Code : EC000941
Version : 7

UL indicator/remote signaling

Operating voltage
125 V AC
Operating current
1 A AC
Tightening torque
4 lbf-in.
Conductor cross section AWG
30 - 14

UL specifications

SPD Type
4CA
Maximum continuous operating voltage MCOV (L-L)
1500 V AC
Maximum continuous operating voltage MCOV (L-G)
750 V AC
Nom. voltage
690 V AC
Mode of protection
L-L
Mode of protection
L-G
Power distribution system
Delta
Nominal frequency
50/60 Hz
Measured limiting voltage MLV (L-L)
4810 V
Measured limiting voltage MLV (L-G)
2560 V
Nominal discharge current In (L-L)
10 kA
Nominal discharge current In (L-G)
10 kA

Additional descriptions

Note
For use in all low-voltage systems between L-PEN. Only for use in IT systems between L-PE if the bodies of the equipment in the low-voltage system are connected to the grounding system of the transformer station. (common grounding of the HV transformer station and the bodies of the LV consumer's installation. RE = RA according to IEC 60364-4-442/VDE 0100-442 Figure 44D/example a)

Dimensions

Height
98.7 mm
Width
53.4 mm
Depth
65.7 mm (incl. DIN rail 7.5 mm)
Horizontal pitch
3 Div.

Connection data

Connection method
Screw connection
Screw thread
M5
Tightening torque
3 Nm (1.5 mm² - 16 mm²)
Tightening torque
4.5 Nm (25 mm² - 35 mm²)
Stripping length
16 mm
Conductor cross section flexible
1.5 mm² - 25 mm²
Conductor cross section solid
1.5 mm² - 35 mm²
Conductor cross section AWG
15 - 2
Connection method
Fork-type cable lug
Conductor cross section flexible
1.5 mm² - 16 mm²

Indicator/remote signaling

Switching function
PDT contact
Operating voltage
5 V AC - 250 V AC
Operating voltage
30 V DC
Operating current
5 mA AC - 1.5 A AC
Operating current
1 A DC
Connection method
Plug-in/screw connection via COMBICON
Screw thread
M2
Tightening torque
0.25 Nm
Stripping length
7 mm
Conductor cross section flexible
0.14 mm² - 1.5 mm²
Conductor cross section solid
0.14 mm² - 1.5 mm²
Conductor cross section AWG
28 - 16

Ambient conditions

Degree of protection
IP20 (only when all terminal points are used)
Ambient temperature (operation)
-40°C - 80°C
Ambient temperature (storage/transport)
-40°C - 80°C
Altitude
‰¤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)
5 % - 95 %
Shock (operation)
25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)
5g (10 - 500 Hz / 2.5 h / X, Y, Z)

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Protective circuit

Nominal voltage UN
554/960 V AC (TN-C)
Nominal voltage UN
690 V AC (IT)
Nominal frequency fN
50 Hz (60 Hz)
Maximum continuous voltage UC
760 V AC
Rated load current IL
80 A
Residual current IPE
‰¤ 1.5 mA
Standby power consumption PC
‰¤ 1200 mVA
Nominal discharge current In (8/20) µs
15 kA
Maximum discharge current Imax (8/20) µs
30 kA
Short-circuit current rating ISCCR
25 kA
Voltage protection level Up
‰¤ 2.9 kV
Residual voltage Ures
‰¤ 2.9 kV (at In)
Residual voltage Ures
‰¤ 2.7 kV (at 10 kA)
Residual voltage Ures
‰¤ 2.5 kV (at 5 kA)
Residual voltage Ures
‰¤ 2.3 kV (at 3 kA)
TOV behavior at UT
1000 V AC (5 s / withstand mode)
TOV behavior at UT
1056 V AC (120 min / safe failure mode)
Response time tA
‰¤ 25 ns
Max. backup fuse with V-type through wiring
80 A (gG)
Max. backup fuse with branch wiring
100 A (gG)

Standards and Regulations

Standards/regulations
IEC 61643-11 2011
Standards/regulations
EN 61643-11 2012

UL connection data

Conductor cross section AWG
10 - 2
Tightening torque
30 lbf-in.

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products