PHOENIX-CONTACT 2882404-Dropship Automation

PHOENIX-CONTACT 2882404

SKU: DA-364943
Availability: 1 In Stock
Product Type: simple
Additional Information Part Number 2882404 UPC 4046356073479 ETIM Group Code : EG000021 Group Description : Earthing, lightning and surge protection Class Description : Surge protection device for terminal equipment Class Code : EC000942 Version : 7 Dimensions Height 103 mm Width 63 mm Depth 78 mm Connection (protective circuit, power supply) Connection method Grounding plug/socket Connection method IN Protective contact...

Additional Information

Part Number
2882404
UPC
4046356073479
ETIM
Group Code : EG000021
Group Description : Earthing, lightning and surge protection
Class Description : Surge protection device for terminal equipment
Class Code : EC000942
Version : 7

Dimensions

Height
103 mm
Width
63 mm
Depth
78 mm

Connection (protective circuit, power supply)

Connection method
Grounding plug/socket
Connection method IN
Protective contact plug CEE7
Connection method OUT
Protective contact socket CEE7

Protective circuit, power supply

EN type
T3
Nominal voltage UN
230 V AC
Arrester rated voltage UC (L-N)
275 V AC
Arrester rated voltage UC (L-PE)
360 V AC
Arrester rated voltage UC (N-PE)
360 V AC
Nominal frequency fN
50 Hz (60 Hz)
Rated load current IL
16 A (30°C)
Standby power consumption PC
‰¤ 1 VA
Residual current IPE
‰¤ 5 µA
Nominal discharge current In (8/20) µs
3 kA (> 5x)
Combination wave UOC
4 kV
Energy absorption symmetrical
140 J (L-N)
Enery absorption, asymmetrical
220 J (L(N)-PE)
Voltage protection level Up (L-N)
‰¤ 1.2 kV
Voltage protection level Up (L-PE)
‰¤ 1.5 kV
Voltage protection level Up (N-PE)
‰¤ 1.5 kV
Response time (L-N)
‰¤ 25 ns
Response time (L-PE)
‰¤ 100 ns
Response time (N-PE)
‰¤ 100 ns
Surge protection fault message
optical
Max. required back-up fuse
16 A (gG / B / C)

Ambient conditions

Ambient temperature (operation)
-25°C - 75°C
Ambient temperature (storage/transport)
-25°C - 75°C

Connection, equipotential bonding, information technology

Connection method
Via protective contact plug

Protective circuit, information technology

Arrester rated voltage UC
200 V DC
Rated current
150 mA (25°C)
Operating effective current IC at UC
‰¤ 150 µA
Residual current IPE
‰¤ 2 µA
Insulation resistance Riso
‰¥ 1 M©
Insulation resistance Riso
‰¥ 1 G©
Nominal discharge current In (8/20) µs (line-line)
1 kA
Nominal discharge current In (8/20) µs (line-earth)
2.5 kA
Max. discharge current Imax (8/20) µs
2.5 kA
Voltage protection level Up (line-line)
‰¤ 460 V (C2 - 1 kA)
Voltage protection level Up (line-line)
‰¤ 350 V (C3 - 25 A)
Voltage protection level Up (line-earth)
‰¤ 900 V (C2 - 2 kA)
Voltage protection level Up (line-earth)
‰¤ 900 V (C3 - 100 A)
Response time tA (line-line)
‰¤ 25 ns
Response time tA (line-earth)
‰¤ 100 ns
Cut-off frequency fg (3 dB), sym. in 100 Ohm system
typ. 4 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ohm system
typ. 3 MHz
Cut-off frequency fg (3 dB), sym. in 600 Ohm system
typ. 700 kHz
Capacity (line-line)
typ. 1 nF
Capacity (line-earth)
typ. 5 pF
Output voltage limitation at 1 kV/µs (wire-wire)
‰¤ 360 V
Residual voltage at In (line-line)
‰¤ 500 V
Residual voltage at In (line-earth)
‰¤ 30 V
Residual voltage with Ian (10/1000) µs (line-line)
‰¤ 35 V
Residual voltage with Ian (10/1000) µs (line-earth)
‰¤ 35 V
Impulse durability (line-line)
C2 - 2 kV / 1 kA
Impulse durability (line-line)
C3 - 25 A
Impulse durability (line-earth)
C2 - 4 kV / 2 kA
Impulse durability (line-earth)
C3 - 100 A
Impulse durability (line-earth)
D1 - 500 A
Alternating current carrying capacity (line-line)
250 mA - 1 s
Alternating current carrying capacity (line-earth)
10 A - 1 s
Pulse reset time (line-line)
‰¤ 15 ms

Standards (protective circuit, information technology)

IEC test classification
C1
IEC test classification
C2
IEC test classification
C3
IEC test classification
D1

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1

Power supply, general

Connection method
RJ12
Connection method IN
RJ12 female connector
Connection method OUT
RJ12 female connector

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products