Additional Information Part Number 2838186 UPC 4017918172855 Country of Origin DE ETIM Group Code : EG000021 Group Description : Earthing, lightning and surge protection Class Description : Surge protection device for data networks/MCR-technology Class Code : EC000943 Version : 7 Dimensions Height 79.6 mm Width 6.2 mm Depth 54.6 mm Connection data Connection method Screw connection Connection method IN Screw...

Additional Information

Part Number
2838186
UPC
4017918172855
Country of Origin
DE
ETIM
Group Code : EG000021
Group Description : Earthing, lightning and surge protection
Class Description : Surge protection device for data networks/MCR-technology
Class Code : EC000943
Version : 7

Dimensions

Height
79.6 mm
Width
6.2 mm
Depth
54.6 mm

Connection data

Connection method
Screw connection
Connection method IN
Screw terminal blocks
Connection method OUT
Screw terminal blocks
Screw thread
M3
Tightening torque
0.6 Nm
Stripping length
8 mm
Conductor cross section flexible
0.2 mm² - 2.5 mm²
Conductor cross section solid
0.2 mm² - 4 mm²
Conductor cross section AWG
24 - 12

Ambient conditions

Ambient temperature (operation)
-40°C - 85°C
Altitude
‰¤ 2000 m
Degree of protection
IP20

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Protective circuit

IEC test classification
C1
IEC test classification
C2
IEC test classification
C3
IEC test classification
D1
Nominal voltage UN
24 V DC
Maximum continuous voltage UC
30 V DC
Rated current
300 mA (40°C)
Operating effective current IC at UC
‰¤ 10 µA
Standby power consumption PC
‰¤ 730 mVA
Residual current IPE
‰¤ 1 µA
Nominal discharge current In (8/20) µs (line-line)
5 kA
Nominal discharge current In (8/20) µs (line-earth)
5 kA
Pulse discharge current Iimp (10/350) µs
500 A
Total discharge current Itotal (8/20) µs
10 kA
Nominal pulse current Ian (10/1000) µs (line-line)
100 A
Nominal pulse current Ian (10/1000) µs (line-earth)
100 A
Output voltage limitation at 1 kV/µs (line-line) spike
‰¤ 45 V
Output voltage limitation at 1 kV/µs (line-earth) spike
‰¤ 650 V
Voltage protection level Up (line-line)
‰¤ 70 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-line)
‰¤ 55 V (C1 - 1 kV/500 A)
Voltage protection level Up (line-line)
‰¤ 45 V (C3 - 10 A)
Voltage protection level Up (line-line)
‰¤ 45 V (C3 - 100 A)
Voltage protection level Up (line-earth)
‰¤ 850 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-earth)
‰¤ 650 V (C1 - 1 kV/500 A)
Voltage protection level Up (line-earth)
‰¤ 850 V (C3 - 10 A)
Voltage protection level Up (line-earth)
‰¤ 900 V (C3 - 100 A)
Voltage protection level Up (line-earth)
‰¤ 800 V (D1 - 500 A)
Response time tA (line-line)
‰¤ 1 ns
Response time tA (line-earth)
‰¤ 100 ns
Input attenuation aE, sym.
typ. 0.6 dB (‰¤ 500 kHz / 50 ©)
Input attenuation aE, sym.
typ. 0.3 dB (‰¤ 160 kHz / 150 ©)
Cut-off frequency fg (3 dB), sym. in 50 Ohm system
typ. 3 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ohm system
typ. 1 MHz
Capacity (line-line)
‰¤ 4 nF
Resistance per path
3.7 © 10 %
Surge protection fault message
none
Max. required back-up fuse
315 mA (T/IEC 60127-2/3)
Impulse durability (line-line)
C1 - 1 kV / 500 A
Impulse durability (line-line)
C2 - 10 kV / 5 kA
Impulse durability (line-line)
C3 - 100 A
Impulse durability (line-earth)
C1 - 1 kV / 500 A
Impulse durability (line-earth)
C2 - 10 kV / 5 kA
Impulse durability (line-earth)
C3 - 100 A
Impulse durability (line-earth)
D1 - 500 A
Alternating current carrying capacity (line-line)
0.25 A / 1 s
Alternating current carrying capacity (line-earth)
0.25 A / 1 s
Pulse reset time (line-line)
‰¤ 400 ms, at Uc and 330 mA
Pulse reset time (line-earth)
‰¤ 400 ms, at Uc and 330 mA

Standards and Regulations

Standards/regulations
IEC 61643-21
Standards/regulations
EN 61643-21
Standards/specifications
IEC 61643-21/A1 2008
Standards/specifications
EN 61643-21/A1 2009

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products