Additional Information Part Number 2800792 UPC 4046356645119 Country of Origin DE Additional descriptions Note Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector. Dimensions Height 91.1 mm Width 17.7 mm Depth 77.5 mm (incl. DIN rail 7.5 mm) Horizontal pitch 1 Div. Connection...

Additional Information

Part Number
2800792
UPC
4046356645119
Country of Origin
DE

Additional descriptions

Note
Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.

Dimensions

Height
91.1 mm
Width
17.7 mm
Depth
77.5 mm (incl. DIN rail 7.5 mm)
Horizontal pitch
1 Div.

Connection data

Connection method
Screw connection
Screw thread
M3
Tightening torque
0.5 Nm
Stripping length
8 mm
Conductor cross section flexible
0.2 mm² - 2.5 mm²
Conductor cross section solid
0.2 mm² - 4 mm²
Conductor cross section AWG
24 - 12

Connection, equipotential bonding

Connection method
DIN rail NS35

Ambient conditions

Ambient temperature (operation)
-40°C - 70°C
Ambient temperature (storage/transport)
-40°C - 85°C
Altitude
? 4000 m (amsl (above mean sea level))
Degree of protection
IP20

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1

Protective circuit

IEC test classification
C1
IEC test classification
C2
IEC test classification
C3
IEC test classification
D1
Nominal voltage UN
5 V DC
Maximum continuous voltage UC
6 V DC
Maximum continuous voltage UC
4 V AC
Rated current
1000 mA (40°C)
Operating effective current IC at UC
? 2 mA (in the signal circuit)
Residual current IPE
? 1 µA
Nominal discharge current In (8/20) µs (line-line)
10 kA
Nominal discharge current In (8/20) µs (line-earth)
10 kA
Pulse discharge current Iimp (10/350) µs (line-earth)
2.5 kA
Total discharge current Itotal (8/20) µs
20 kA
Voltage protection level Up (line-line)
? 85 V (C1 - 1 kV/500 A)
Voltage protection level Up (line-line)
? 110 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-line)
? 140 V (C2 - 10 kA)
Voltage protection level Up (line-line)
? 25 V (C3 - 25 A)
Voltage protection level Up (line-line)
? 25 V (C3 - 50 A)
Voltage protection level Up (line-earth)
? 900 V (C1 - 1 kV/500 A)
Voltage protection level Up (line-earth)
? 1300 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-earth)
? 1200 V (C2 - 10 kA)
Voltage protection level Up (line-earth)
? 1000 V (C3 - 25 A)
Voltage protection level Up (line-earth)
? 1300 V (C3 - 100 A)
Voltage protection level Up (line-signalground)
? 600 V (C1 - 1 kV/500 A)
Voltage protection level Up (line-signalground)
? 750 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-signalground)
? 800 V (C2 - 10 kA)
Voltage protection level Up (line-signalground)
? 700 V (C3 - 25 A)
Voltage protection level Up (line-signalground)
? 800 V (C3 - 100 A)
Voltage protection level Up static (line-line)
? 26 V (C1 - 1 kV/500 A)
Voltage protection level Up static (line-line)
? 70 V (C2 - 10 kV / 5 kA)
Voltage protection level Up static (line-line)
? 30 V (C2 - 10 kA)
Response time tA (line-line)
? 1 ns
Response time tA (line-signalground)
? 100 ns
Response time tA (line-earth)
? 100 ns
Input attenuation aE, sym.
typ. 0.3 dB (? 40 kHz/150 ?)
Cut-off frequency fg (3 dB), sym. in 150 Ohm system
typ. 300 kHz
Capacity (line-earth)
typ. 7.5 nF
Resistance in series
1.2 ? ±5 %
Surge protection fault message
Optical, multi-stage
Max. required back-up fuse
1 A (FF)
Impulse durability (line-line)
C1 - 1 kV/500 A
Impulse durability (line-line)
C2 - 10 kV/5 kA
Impulse durability (line-line)
C2 - 10 kA
Impulse durability (line-line)
C3 - 50 A
Impulse durability (line-earth)
C1 - 1 kV/500 A
Impulse durability (line-earth)
C2 - 10 kV/5 kA
Impulse durability (line-earth)
C2 - 10 kA
Impulse durability (line-earth)
C3 - 100 A
Impulse durability (line-earth)
D1 - 2.5 kA
Impulse durability (line-signalground)
C1 - 1 kV/500 A
Impulse durability (line-signalground)
C2 - 10 kV/5 kA
Impulse durability (line-signalground)
C2 - 10 kA
Impulse durability (line-signalground)
C3 - 100 A
Impulse durability (line-signalground)
D1 - 2,5 kA
Pulse reset time (line-line)
? 10 ms
Pulse reset time (line-earth)
? 10 ms
Pulse reset time (line-signalground)
? 10 ms

Standards and Regulations

Standards/specifications
IEC 61643-21 2000 + A1:2008, modified
Standards/specifications
EN 61643-21 2001 + A1:2009
Standards/specifications
EN 61000-6-3 2007 + A1:2011
Standards/specifications
EN 61000-6-2 2005

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Recently Viewed Products